E-mail
401235598@qq.com
-
Phone
18115804444,18901490444
-
Address
No. 83, Huacheng Middle Road, Jintan, Changzhou City
Changzhou National Experimental Equipment Research Institute
401235598@qq.com
18115804444,18901490444
No. 83, Huacheng Middle Road, Jintan, Changzhou City
Walk in high and low temperature test chamberCustomization can be made according to the needs provided by customers: the size is determined by the selection of the outer box of the test box, and also provides testing space for high and low temperature testing of parts, semi-finished products, and finished products in the industry. The inner box volume is 1 cubic meter to 100 cubic meters
Product Structure Features:
The walk-in high and low temperature test chamber adopts a base made of rigid polyurethane foam board and channel steel surface electrostatically sprayed, which can be customized according to customer requirements for size and site design, and the internal size can be expanded freely
◆ Equipped with a low voice refrigeration device that can monitor internal parameters of the instrument, it has the ability to diagnose and repair equipment faults, and has an alarm function when faults occur
◆ Imported temperature control equipment is used internally, which can quickly adjust the temperature of the test chamber, set multiple parameters to write programs, and has PID adjustment function
◆ Equipped with shock-absorbing pads, the constant temperature and humidity testing machine can maintain quietness and stability during operation, with constant operation and program operation
◆ Arc shaped and matte line treatment, high-quality appearance, and use flat non reactive handles for safe operation
The refrigeration system adopts a high cooling capacity, high-efficiency maintenance free compressor. We adopt a binary cascade refrigeration method to import environmentally friendly refrigerants, and the cooling capacity is controlled by servo control valves imported from the United States.
Walk in high and low temperature test chamberCustomizable sizes available
Model/Internal volume (cubic feet) Internal dimensions (width X depth X height)
BRS-683 7'1'w x 10'11'd x 8'10'h (216 cm x 333 cm x 269 cm)
BRS-769 9'w x 10'11'd x 7'10'h (274 cm x 333 cm x 239 cm)
BRS-1237 10'11'w x 12'10'd x 8'10'h (333cm x 391cm x 269cm)
BRS-1261 10'11'w x 14'9'd x 7'10'h (333cm x450cm x239cm)
BRS-1422 10'11'w x 14'9'd x 8'10'h (333cm x450cm x269cm)
BRS-286 5'2'w x 7'1'd x 7'10'h (157cm x 216cm x 239cm)
BRS-323 5'2'w x 7'1'd x 8'10'h (157cm x 216cm x 269cm)
BRS-867 9'w x 10'11'd x 8'10'h (274 cm x 333 cm x 269 cm)
BRS-904 9'w x 12'10'd x 7'10'h (274 cm x 391 cm x 239 cm)
BRS-1020 9'w x 12'10'd x 8'10'h (274cm x 391cm x 269cm)
BRS-1097 10'11'w x 12'10'd x 7'10'h (333cm x 391cm x 239cm)
BRS-364 5'2'w x 9'd x 7'10'h (157cm x274cm x239cm)
BRS-410 5'2'w x 9'd x 8'10'h (157cm x274cm x269cm)
BRS-499 7'1'w x 9'd x 7'10'h (216 cm x 274 cm x 239 cm)
BRS-563 7'1'w x 9'd x 8'10'h (216 cm x 274 cm x 269 cm)
BRS-605 7'1'w x 10'11'd x 7'10'h (216 cm x 333 cm x 239 cm)
Model and Capacity:
| model | THL-09 | THL-10 | THL-15 | THL-30 | THL-50 | THL-80 | |||
| Volume(m3) | 9 | 10 | 15 | 30 | 80 | 120 | |||
|
Internal dimensions(cm) | D | 250 | 280 | 300 | 500 | 700 | 800 | ||
| W | 200 | 200 | 250 | 300 | 500 | 500 | |||
| H | 180 | 180 | 200 | 200 | 250 | 300 | |||
Walk in high and low temperature test chamberPerformance characteristics:
(1) The temperature range that can be set in the laboratory is relatively wide: A: 0 ℃; B:-20℃; C:-40℃; D: -60 ℃/High temperature: 80 ℃~150 ℃, usually the highest test temperature is 85 ° C; the lowest test temperature is Min: -20 ° C/-40 ° C/-60 ° C. The product can be designed for higher or lower temperatures according to customer needs.
(2) High humidity range control accuracy: 20% -98% RH (special requirements: 5% -98% RH; 10% -98% RH)
(3) Due to the adoption of *'s air duct system design and electrical control system, the temperature uniformity of the entire room can be maintained, and the heating and cooling rate can be extended to -2.0-10.0 ℃ per minute according to customer requirements
(4) The box is fully CNC controlled, with exquisite appearance and extremely small gaps. The outer box and inner liner are both made of first-class 304 stainless steel, which is resistant to high temperature and corrosion, and has practical and durable characteristics
(5) The box is usually composed of enclosure structure, air duct system, control system, indoor testing architecture, etc.
(6) The box structure is generally assembled on site using insulation boards (double-sided colored steel plates with insulation materials added in the middle), and the room dimensions are designed according to customer requirements
Walk in high and low temperature test chamberSafety devices: leakage circuit breaker, dry burning protector (humidification system), water system protection, fan overheating protection, compressor overpressure, overheating, overcurrent protection, phase sequence protection, overtemperature protection, temperature fuse.