Liquid tank temperature shock test chamber
Environmental conditions have a significant impact on the functionality and reliability of electrical components, equipment, and devices. In order to detect potential defects in a short period of time, conventional temperature testing alone is usually not enough; The sample must be subjected to severe temperature changes multiple times. Use our temperature shock test chamber to achieve extremely fast temperature switching within the range of -65 ° C to+180 ° C. As a result, you can reduce the risk of early failure and improve the reliability of your product. Renewable, certified, and durable.
Liquid tank temperature shock test chamber
If an explosive mixture is formed, it may lead to unexpected events during the experiment.
Flammable, combustible or explosive substances (such as liquids, gases) overflow from the test sample and enter the laboratory air.
If the gas concentration of a substance is within a specific limit, then the gas mixture is at risk of explosion.
The boundaries are marked as LEL and UEL (lower and upper explosive limits) and are specified in the material safety data page.
When there is a risk of fire or explosion, safety measures need to be taken for the system based on the potential danger (risk).
Due to the installation of internal components that are essential for the functionality of our equipment, such as heating devices, lighting devices, etc., there may be potential sources of ignition.
We can modify and expand the equipment, or install safety devices to make the equipment comply with the ATEX directive
Model (CM) |
SET-A |
SET-B |
SET-C |
SET-D |
SET-G |
|
internal dimensions |
40×35×35 |
50×50×40 |
60×50×50 |
70×60×60 |
80×70×60 |
|
external dimensions |
140×165×165 |
150×190×175 |
160×190×185 |
170×240×195 |
180×260×200 |
|
structure |
Three box type (pre cooling box) (preheating box) (testing box) |
|||||
Damper Device |
Mandatory air device valve |
|||||
Inner box material |
SUS#304stainless steel |
|||||
outer box material |
Cold rolled steel plate electrostatic spraying |
|||||
Freezing system |
Mechanical compression binary cascade refrigeration method |
|||||
Convert time |
<10Sec |
|||||
Temperature recovery time |
<5min |
|||||
Temperature Uniformity |
<2℃ |
|||||
temperature fluctuation |
≤±0.5℃ |
|||||
temperature deviation |
±2℃ |
|||||
cooling method |
water cooling |
|||||
dwell time |
30 min |
|||||
temperature range |
preheating temperature |
+60~200℃(40min) |
||||
High temperature impact |
+60~150℃ |
|||||
Pre cooling temperature |
+20℃~-80℃(70min) |
|||||
low temperature impact |
-10℃~-40℃/-55℃/-65℃ |
|||||
temperature sensor |
JIS RTD PT100Ω× 3 (platinum sensor) |
|||||
controller |
LCD touch screen PLC controller |
|||||
Control method |
By relying on integral saturation PID, fuzzy algorithm balanced temperature control P.I.D+P.W.M+S.S.R |
|||||
Standard Configuration |
1 set of illuminated glass windows, 2 sample racks, and 1 test lead hole are attached |
|||||
safety protection |
Leakage, short circuit, overheating, water shortage, motor overheating, compressor overpressure, overload, overcurrent protection |
|||||
power supply voltage |
AC380V 50HzThree phase four wire+grounding wire |
|||||