M6 desktop single quadrupole gas chromatography-mass spectrometry
The entire system consists of the following parts: Universal M6 Single Quadrupole Mass Spectrometer
Agilent 7890A gas chromatograph
Agilent 7683 automatic liquid sampler (optional)
Computer system (optional)
M7 Chemical Workstation Software
Technical Specifications:
Technical performance indicators
Quality range 1.5-1050 amu
Quality accuracy ± 0.1amu
Resolution (R) W1/2<1 amu (resolution per unit mass)
Signal to noise ratio (EI) 5pg octafluoronaphthalene full scan, signal-to-noise ratio ≥ 1501 RMS at m/z 272; 500fg octafluoronaphthalene selective ion scanning, signal-to-noise ratio ≥ 1501 RMS at m/z 272
Quality stability ± 0.1 amu/48 hours
Maximum scanning speed of 10000 amu/s
Vacuum degree ≤ 4 × 10-4 Pa
Measurement repeatability of 10ng hexachlorobenzene m/z 284, RSD ≤ 9%
Retrieve 10ng methyl stearate from the spectral library, with a similarity of ≥ 75%
Model and configuration
Model configuration instructions: M6-60AAgilent7890A gas chromatography, mass spectrometry host equipped with German Pfeiffer 60L/s small turbo molecular pump M6-210Agilent7890A gas chromatography, mass spectrometry host equipped with German Pfeiffer 210L/s small turbo molecular pump
Main Features
vacuum system
A high-performance vacuum system consisting of a front-end vacuum pump and a turbo molecular pump reduces ion collisions, background noise, and memory effects.
The front stage vacuum pump adopts GLD-N201 small direct coupled oil rotary plate vacuum pump with a geometric pumping speed of 4L/s.
Two specifications of small turbo molecular pumps, providing * * performance to meet your needs and budget.
TMH071P magnetic levitation small turbo molecular pump, geometric pumping speed of 60L/S (standard configuration).
TMH262P magnetic levitation small turbo molecular pump, with a geometric pumping speed of 210L/S (optional).
Cold cathode ionization vacuum gauge, detection range 1.0 × 10-5~1 × 102 Pa
ion source
An independently heated EI electron bombardment source with a maximum temperature of 350 ℃.
The maximum filament emission current is 200 μ A.
The electronic energy is adjustable from 10-100eV and has low voltage operation function.
The overall plug-in design allows for easy maintenance of the ion source without the need for complex operations.
quadrupole mass filter
The high-precision metal quadrupole mass analyzer ensures the achievement of standard unit mass resolution.
Detachable pre quadrupole filtering device reduces contamination of the main quadrupole and avoids cleaning and maintenance of the quadrupole.
The pre quadrupole filtering device is equipped with a voltage that varies with the scanning quality, which can improve the edge field, increase the ion incidence efficiency, and achieve better detection sensitivity.
detector
High voltage conversion nanograde electron multiplier.
The small signal amplifier of composite I/V conversion circuit technology effectively reduces circuit noise, improves signal-to-noise ratio, and ensures excellent linear dynamic range.
electronic system
High quality RF power supply can achieve full quality range quality axis calibration with just two points, maintaining good linearity in full scan mode.
Excellent electromagnetic compatibility design and high-precision, low-temperature drift electronic components ensure excellent quality accuracy and stability of the instrument.
32-bit embedded control system, using 100Mbps Ethernet communication interface, can achieve remote control and networked sharing.
A highly modular power system and control circuit system enhance the overall reliability of the instrument, facilitating maintenance and upgrades.
software system
The Chinese software system is divided into four functional modules: instrument control, data acquisition, data processing, and spectrum retrieval (NIST08). Intuitive and intelligent, easy to operate.
Technical Specifications
Technical specifications Performance quality range 1.5-1050u Quality accuracy ± 0.1u Resolution (R) Unit mass resolution Signal to noise ratio (EI) 5pg Octafluoronaphthalene Full scan, Signal to noise ratio ≥ 1501 RMS at m/z272; 500fg octafluoronaphthalene selective ion scanning, signal-to-noise ratio ≥ 1501 RMS at m/z 272, quality stability ± 0.1 u/48h, maximum scanning speed 10000 u/s
M6Desktop single quadrupole gas chromatography-mass spectrometryProduct advantages
The dual filament design of the ion source provides twice the lifespan of the filament, ensuring continuous and reliable experiments;
Equipped with the German PFEIFFER turbo molecular pump, it is sturdy and durable, ensuring high vacuum requirements for the system;
• Graphic workstation design, easy to operate and flexible;
LAN communication port, ensuring human-machine separation and remote access;
Built in method database, reducing method development time and improving analysis efficiency.