The MF5000 series gas mass flow meter is an intelligent fully electronic gas mass flow meter developed after years of combining microcomputer (MEMS) flow sensing chip technology and computer adaptive technology. Its main technical performance is at the international level, and it has the characteristics of high sensitivity, high precision, and large range ratio; For industrial environments
MF5000 series gas mass flowmeterIt is an intelligent fully electronic gas mass flow meter developed after years of combining microcomputer (MEMS) flow sensing chip technology and computer adaptive technology. Its main technical performance is at the international level, and it has the characteristics of high sensitivity, high precision, and large range ratio; Electromagnetic compatibility design that integrates multiple anti-interference measures for industrial environments; And it has multiple signal outputs, which can achieve network management functions through communication interfaces; This product also has its own characteristics in terms of performance, installation, and maintenance, and can be widely used in various fields such as petroleum, gas, chemical, smelting, and energy. Product features: Using microcomputer chip processing technology and large-scale integrated circuit production technology, as well as material growth technology, the size of the sensor has been reduced to the micrometer level, greatly improving the sensitivity of the flowmeter. -Multi sensor integration has been achieved on a single chip, greatly improving the range ratio (range) of the flowmeter. -The zero stability of the sensor has greatly improved compared to traditional thermal mass flow meters. -Combining the microcomputer intelligent technology of secondary instruments, the flowmeter has good repeatability and achieves accurate and reliable measurement. -The structural simplification brought about by technological progress has greatly reduced the pressure loss of flow meters compared to traditional mechanical instruments, greatly reducing energy consumption. -Adopting LCD display for 'instantaneous flow' and 'cumulative flow', clear and intuitive, and easy to read. -The product integrates electromagnetic compatibility design technology and has higher anti-interference ability. -The flowmeter is equipped with an RS485 communication module, which can be centrally managed in conjunction with the upper computer network. -Optional 4-20mA standard current signal output is available.
MF5000 series gas mass flowmeterProduct Features:
By adopting micro electromechanical system chip processing technology, large-scale integrated circuit production technology, and material growth technology, the size of the sensor has been reduced to the micrometer level, greatly improving the sensitivity of the flowmeter.
-Multi sensor integration has been achieved on a single chip, greatly improving the range ratio (range) of the flowmeter.
-The zero stability of the sensor has been greatly improved compared to traditional thermal mass flow meters.
-Combining the microcomputer intelligent technology of secondary instruments, the flowmeter has good repeatability and achieves accurate and reliable measurement.
-The structural simplification brought about by technological progress has greatly reduced pressure loss and energy consumption compared to traditional mechanical instruments for flow calculation.
-adoptLCDdisplay'instantaneous flow rate'and'cumulative flow'Clear and intuitive, easy to read.
-The product integrates electromagnetic compatibility design technology and has higher anti-interference ability.
-Flow meter withRS485The communication module, in conjunction with the upper computer network, can achieve centralized management.
-Optional4~20mAStandard current signal output.
Mechanical dimensions of flowmeter:
model |
path (mm) |
interface (inch) |
L |
H |
W |
d |
a |
b |
c |
MF5003 |
3 |
1/8' |
85 |
124 |
35 |
Φ3 |
25 |
16 |
50 |
MF5006 |
6 |
1/4' |
95 |
127 |
35 |
Φ6 |
25 |
18 |
50 |
MF5008 |
8 |
3/8' |
105 |
134 |
35 |
Φ8 |
25 |
22 |
50 |
MF5012 |
12 |
1/2' |
116 |
137 |
40 |
Φ12 |
30 |
25 |
50 |
MF5019 |
19 |
3/4' |
152 |
149 |
40 |
Φ19 |
30 |
40 |
70 |
Technical Specifications:
precision±(1.5+0.2FS)%
measurement range0.01~65m/sec
Measure the pipe diameter1~19 mm
Usage environment temperature: -20~65
apparent show instantaneous flow rate;cumulative flow
output mode4~20mA; RS485;pulse
Calibration conditions 20oC; 101.325 kPa.
Product selection:
model |
path (mm) |
interface (inch) |
Great work pressure (MPa) |
measurement range |
sccm |
SLPM |
SCFM |
NCMH |
MF5003 |
3 |
1/8' |
1.5 |
15-1500 |
0.15-15 |
|
|
MF5006 |
6 |
1/4' |
1.5 |
|
0.5-50 |
0.02-2 |
0.035-3.5 |
MF5008 |
8 |
3/8' |
1.5 |
|
1.2-120 |
0.045-4.5 |
0.075-7.5 |
MF5012 |
12 |
1/2' |
1.5 |
|
3-300 |
0.1-10 |
0.17-17 |
MF5019 |
19 |
3/4' |
1.5 |
|
8-800 |
0.28-28 |
0.48-48
|