Detailed information on dry well temperature calibration furnace:

MY-S100 Dry Well Temperature Calibration InstrumentDry furnace, also known as dry well, dry well furnace, dry measuring furnace, temperature measuring furnace, temperature calibrator, dry type temperature calibration furnace. Dry body furnace is a convenient and portable device with fast temperature rise and fall speed,traditionThe on-site heat source (temperature field) is used, and the dry body furnace adopts a high stability temperature controller. The homogenization block is made of alloy material with good thermal conductivity. Technologically, it belongs to the high temperature industry and is at the same level of high-tech technology synchronization. In terms of insertion depth, horizontal temperature field, vertical temperature field and other technical aspects, it is in a leading positionhigh technologyLevel. Used within the required temperature range, it is widely used in industries that require on-site temperature calibration, such as pharmaceuticals (GMP wet heat sterilization, dry heat sterilization), machinery, ships, chemicals, biological products, power plant substations, steel plants, metrology testing, scientific research, etc. A dry furnace can provide a stable, uniform, and accurate temperature environment (temperature field), similar to a constant temperature bath (liquid bath), but it is easy to carry and does not require the placement of liquids. The time for the dry furnace to reach the predetermined temperature point and stabilize the temperature is 5 to 10 times faster than that of a constant temperature bath, which can greatly save the time of calibration personnel and improve the speed of temperature calibration. The portability of the dry furnace enables on-site calibration work, thereby solving the difficulty of transporting and moving the constant temperature bath. Temperature sensors such as mercury thermometers, expansion thermometers, thermocouples, thermistors, etc. can be easily calibrated through a dry body furnace.
The dry well temperature calibrator has the following product features:
*More portable and lightweight. Higher accuracy.
*Human computer interface, Chinese display, touch operation, beautiful and elegant.
*One click temperature setting, easy to operate. Quickly heat up and control the temperature.
*According to customer requirements, language interfaces from anywhere in the world can be copiedExit easily.
Dry well temperature calibratorTechnical guidance:
typenumber |
MY-S100 |
WenRange of degrees(When the room temperature is ≤ 22 ℃) |
-100℃ -40℃ |
display resolution |
0.01℃ |
Control method |
touch screen |
accuracy |
±0.3℃ |
Radial uniformity |
±0.2℃ |
Verify hole depth |
145mm |
Default display |
Chinese display full color LCD ℃or ℉ |
Diameter of uniform heating block |
30mm |
Verify hole diameter |
4mm、6mm、8mm、 10mm(Customizable) |
Number of verification holes |
4 (customizable) |
size(Long)X wide X tall) |
320mmX 195mm X530mm |
weight |
15.2KG |
power supply |
220V AC 50HZ |
adjustment method |
Automatic power adjustment |
language |
According to customer requirementsCan copy languages from anywhere in the world |
working conditions |
20℃—25℃ 80%RH |
1.111**
*
*(* 8 * * Precautions for using dry well temperature calibrator:
*In front of the machinefirstCheck for any abnormalities in the equipment(such as bumps and other phenomena). If there is any abnormal noise when starting up, the power should be turned off immediatelyContact the source and manufacturer,If not available, it can be turned on and run.
*When used on site, the power plug should be reliably groundedInsert the device plug into the bottom of the device to avoid poor contactThe current equipment is on fireElephant.
*To ensure temperature measurement accuracy and ideal usage environmentThe temperature should≤25℃
*The testing work must start from the low temperature point firstGo to the high temperature point again to avoid the rapid temperature changes affecting the furnaceDamage caused by electronic components; When the device stops using, the first thing to do is to prohibit itDirectly set low temperature from high temperature for cooling, and secondlyIt is prohibited to directly operate the equipment above 100 ℃Shut down to avoid damage to the device!
*The standard aperture on the temperature equalization block is4mm/6mm/6mm/8mm/10mmPut the tested sensor into the inspection When drilling, the diameter of the detection hole should be larger than the diameter of the sensor being testedThe diameter shall not exceed 0.5mm.
*Example:asIf the diameter of the tested sensor is 5.5mm, it should be placed in a 6mm aperture instead of 8mm or 10mm The aperture, otherwise it willAffects test results. If the standard size cannot meet the inspection requirements, it should be promptly reported to our companyContact, SpecialCustomized verification aperture.
*The calibration hole depth on the temperature equalization block is standard at 165mmThe armored part of the tested sensor should≥165mm, Put in verification The bottom of the hole should be in contact with the bottom surface to avoid affecting the test results.If the length of the armored part of the tested sensor is ≤165mmIt should beContact our company promptly and inform them of the testing method or special customized dry body furnace.
*During transportation, the heat equalizing block should be individually packaged and strictly prohibited from being placedTransport inside the device together with the equipment to avoid transportation during the processThe heavy impact of the temperature equalization block caused damage to the equipment; Average temperature during useBlock application temperature equalization block handle tightened slowly and placed into the deviceChinese.
*Before installing or moving the instrument, please turn off the power to avoid accidents such as electric shock.
*If the equipment is not used for a long time, be sure to put it awayKeep in a cool and ventilated environment to avoid damage to equipment components caused by humid conditions.