Portable temperature calibratorDetailed information:
=
MY-S200 portable temperature calibratorAlso known as dry well, dry well furnace, dry metering furnace, temperature metering furnace, temperature calibrator, dry type temperature calibration furnace. Dry body furnace is a convenient portable, fast temperature rise and fall, traditionalThe on-site heat source (temperature field) is used, and the dry furnace adopts a high stability temperature controller. The uniform heating block is made of alloy material with good thermal conductivity. In terms of technology andDomestic highTechnological synchronization, in terms of insertion depth, horizontal temperature field, vertical temperature field, etchigh technologyLevel. Portable temperature calibrators are widely used in industries that require on-site temperature calibration, such as pharmaceuticals (GMP wet heat sterilization, dry heat sterilization), machinery, ships, chemicals, biological products, power plant substations, steel plants, metrology testing, scientific research, etc., within the required temperature range.
Portable temperature calibrator can provide a stable, uniform, and accurate temperature environment(Temperature field), providing a similarconstantThe performance of the warm bath (liquid bath), but the dry furnace is easy to carry and does not require the placement of liquids. The dry furnace has reached the predetermined temperature point andThe time for temperature stability is faster than that of a constant temperature bath5 to 10 times, which can greatly save calibration personnelTime, improve temperature calibration speed. The portability of the dry furnace enables on-site calibration work, thereby solving the difficulty of transporting and moving the constant temperature bath. Temperature sensors such as mercury thermometers, expansion thermometers, thermocouples, thermistors, etc. can be easily calibrated through a dry body furnace.
Portable temperature calibration furnaceMain Features
Small size, light weight, easy to carry;
Multiple types of insertion pipes can meet different sizes and quantities of sensors
Testing and calibration. And it can be customized according to the special needs of users; Good horizontal and vertical temperature fields; The insertion depth of the sensor is deeper than other manufacturers.
5.0inchTFTLCDtouch screen,16True color image, easy and intuitive to use;
Fast cooling speed, easy to set, and stable temperature control; The heat equalizing block can be replaced;
It has functions such as load short circuit, load circuit, sensor protection, etc.
Portable dry body temperature calibratorTechnical Indicators:
model |
MY-S200 |
WenRange of degrees(When the room temperature is ≤ 22 ℃) |
-30℃ -200℃,-20-200℃,-10-200℃,0-200℃ |
display resolution |
0.01℃,0.001℃ |
Control method |
touch screen |
accuracy |
±0.3℃ |
Radial uniformity |
±0.2℃ |
Verify hole depth |
160mm |
Default display |
Chinese display full colorLCD℃or℉ |
Diameter of uniform heating block |
30mm |
Verify hole diameter |
4mm, 6mm, 8mm, 10mm (customizable) |
Number of verification holes |
4 (customizable) |
size(Long X)wideXtall) |
320mmX 195mm X530mm |
weight |
15.2KG |
power supply |
220/110V AC 50/60HZ |
adjustment method |
Automatic power adjustment |
language |
According to customer requirements, languages from anywhere in the world can be copied |
working conditions |
20℃—25℃ 80%RH |
Precautions for portable dry body temperature calibrator:
*Before starting upfirstCheck for any abnormalities in the equipment(such as bumps and other phenomena). If there is any abnormal noise when starting up, immediately turn off the power and contact the manufacturer. If there is no noise, you can start up and run.
*When using on site, the power plug should be reliably grounded! Insert the device plug into the bottom of the device to avoid poor contactThe current equipment is experiencing ignition.
*To ensure temperature measurement accuracy and ideal usage environmentThe temperature should be ≤ 25 ℃.
*The detection work must start from the low temperature point and then go to the high temperature point to avoid the rapid temperature changes affecting the furnaceDamage caused by electronic components; When the device stops using, the first thing to do is to prohibit itDirectly set low temperature from high temperature to cool down, and secondly Equipment isDo not shut down directly when the temperature is above 100 ℃ to avoid damage to the equipment!
*The standard aperture on the temperature equalization block is4mm/6mm/6mm/8mm/10mm, When the tested sensor is placed in the detection hole, the diameter of the detection hole should be larger than the diameter of the sensorDiameter not exceeding0.5mm。
*Example:as: Diameter of the inspected sensor5.5mm, It should be placed with a 6mm aperture, not 8mm or 10mm apertures, otherwise it will affect the test results. If the standard size cannot meet the inspection requirements, you should contact our company in a timely manner to customize and verify the aperture.
*Calibration hole depth on the temperature equalization block is standard165mm, The armored part of the tested sensor should be ≥ 165mm and placed for verificationAt the bottom of the hole, it contacts the bottom surface, To avoid affecting the test results . If the length of the armored part of the tested sensor is ≤165mm, You should contact our company in a timely manner to inform them of the testing method or special customized dry body furnace.
*During transportation, the heat equalizing block should be separately packaged and strictly prohibited from being placed inside the equipment for transportation together with the equipment to avoid transportation during the processThe heavy impact of the temperature equalization block caused damage to the equipment; Average temperature during useBlock application temperature equalization block handle tightened slowly and placed into the deviceIn the middle.
*Before installing or moving the instrument, please turn off the power to avoid accidents such as electric shock.
*If the equipment is not used for a long time, it must be placed in a cool and ventilated environment to avoid damage caused by humid conditions Damage caused by spare components
Portable temperature calibratormaintain:
1. General maintenance and malfunctions
2 Instrument calibration should1Around one year, to ensure that the instrument's indicators meet the requirements.
3.Replace the fuse tube
The fuse tube is installed below the power socket switch. Fuse tube specifications:5A250VOperation steps of type fuse:
4 Turn off the power and unplug the power cord.
5 Find the location of the fuse and remove the blown fuse according to the equipment.
Replace the fuse tube with a new one and reinstall it.
Common faults and their solutions.
When the following abnormal phenomena occur during use, it cannot be concluded that the dry furnace is faulty. Please carefully check again before sending it out for maintenance.
Fault phenomenon |
Possible reasons |
treatment method |
|
Unable to heat up.
|
1.Not connected to the power supply. 2.The temperature controller switch has not been turned on. 3.The electric furnace switch has not been turned on |
1.Plug in the power plug tightly. 2.Turn on the temperature controller switch 3.Turn on the electric furnace switch. |
|
The heating time is too long |
1.The furnace mouth is not blocked. |
1.Block the furnace with high-temperature cotton. |
|
The furnace is unstable |
1There is a leakage phenomenon. 2.The constant temperature block is not evenly heated. |
1.Safe grounding. 2.Let the constant temperature block heat up evenly. |
Furnace power outage |
Fuse damaged |
Timely replace the fuse |
After the above inspection, the fault cannot be eliminated. Please contact our company in a timely manner.
Friendly reminder: Before transportation, please gently lift the heating block inside the furnace and do not transport it inside the furnace!!!
When using the equalizing block, please align the separate hole under the equalizing block with the temperature control thermocouple at the bottom of the furnace and gently insert it into the furnace!!!