model YCH-080 YCH-150 YCH-225 YCH-408 YCH-800 YCH-1000
Inner box size (cm) 40×50×40 50×60×50 60×75×50 80×85×60 100×100×80 100×100×100
Outer box size (cm) 60x172x120 70x174x130 70x172x181 100x182x197 120x197x197 120x197x217
temperature range -70 ℃, -60 ℃, -40 ℃, -20 ℃, 0 ℃~150 ℃, other temperatures can be customized
humidity range 20% RH~98% RH (low humidity 10% RH~98% RH or 5% RH~98% RH can be customized)
Temperature and humidity fluctuation ±0.3℃; ± 0.5%RH
Uniformity of temperature and humidity ±2℃; ± 3% RH (unloaded, 30 minutes after stabilization)
Analysis accuracy 0.01℃; 0.1%RH
Heating and cooling time Heating up: an average of 3 degrees per minute; Cooling: An average of 1 degree per minute
outer box material Cold rolled plate+baked paint
Inner box material SUS # 304 stainless steel plate
thermal insulation material PU
circulatory system Centrifugal fan air circulation system
heating system SUS # stainless steel high-speed heater
Humidification system Electric heating steam humidification
Dehumidification system ADP critical dew point cooling/dehumidification method
refrigeration system Compressor+finned evaporator+air-cooled (water-cooled) condenser
control system Touch LCD display screen+SSR+PID
Attachment Vacuum glass observation window
Power on test hole (50mm)
Control status indicator light
Window light
Partition rack (2 pieces, adjustable height)
protective device Overheating protection circuit breaker
Overheating protection for humidification system
Compressor overload protection
Control system overload protection
Overload indicator light
phase sequence protection
water scarcity protection
High voltage and low voltage protection
overtemperature protection
Water replenishment delay protection
Fan overcurrent protection
power supply AC 1Ψ 220V; 3Ψ 380V 60/50Hz
customized service Non standard special requirements, customizable

Maintenance of constant temperature and humidity chamberoperationNotes:
If the high and low temperature test chamber is found to be damaged or deformed when opening the box, please do not use it.
To prevent electric shock or misoperation and malfunction, please do not connect the power supply before installation and wiring are completed.
3. This product is not explosion-proof, please do not use the constant temperature and humidity machine in environments with flammable or explosive gases.
4. When installing and setting up high and low temperature boxes, be careful not to let dust, wire ends, iron filings, or other things enter, otherwise incorrect actions or malfunctions may occur.
5. It is prohibited to dismantle, process, modify or repair the constant temperature and humidity machine without authorization, otherwise there is a risk of abnormal operation, electric shock or fire.
6. The ventilation holes of the body should be kept unobstructed to prevent malfunctions, abnormal movements, reduced lifespan, and fires.
7. During the operation of the constant temperature and humidity chamber, please try not to open the door of the test chamber of the constant temperature and humidity machine. Opening it at high temperatures may cause burns to the operators, while opening it at low temperatures may cause early frostbite to the workers, and may also cause the evaporator to freeze, affecting the cooling effect. If you must open it, please take certain protective measures.
8. The wiring must be correct and grounded. Not grounding may cause electric shock, incorrect operation accidents, abnormal display, or significant measurement errors.
9. The internal components of the high and low temperature chambers have a certain lifespan. To ensure the continuous and safe use of this instrument, please perform regular maintenance and upkeep. When scrapping this product, please dispose of it as industrial waste.
During the operation of the instrument, the power input terminal cover must be installed on the terminal board to prevent electric shock.
Before modifying settings, outputting signals, starting, stopping, and other operations during the operation of the instrument, safety should be fully considered. Incorrect operations may cause damage or malfunction to the working equipment.
12. Regularly check the terminal screws and fixing brackets, please do not use them when they are loose.
13. Please use a dry cloth to wipe the instrument, do not use alcohol, gasoline, or other organic solvents, and do not splash water on the instrument. If the instrument is immersed in water, please stop using it immediately, otherwise there is a risk of electric leakage, shock, or fire. Even damaging your device.
14. To avoid machine malfunctions in the high and low temperature test chamber, please provide a power supply within the rated voltage range. This is for the safety of both the machine and itself.


Maintenance of constant temperature and humidity chamber
  • Using Korean controller, supporting 5 different languages
  • Automatic replenishment function (optional)
  • Can support computer operation and real-time monitoring
  • Non standard customized services