The medical device packaging sealing integrity tester is a non-destructive micro leak detection device specially developed for flexible packaging. The sealing detection device adopts Paratronix's independently developed leak detection technology and software, ensuring the integrity of various types of flexible packaging for users. This technology and equipment are widely used in industries such as food, pharmaceuticals, and medical devices.


Product Introduction:
Medical Device Packaging Sealing Integrity TesterIt is a non-destructive micro leak detection device specially developed for flexible packaging. The sealing detection device adopts Paratronix's independently developed leak detection technology and software, ensuring the integrity of various types of flexible packaging for users. This technology and equipment are widely used in industries such as food, pharmaceuticals, and medical devices.
Technical advantages:
Suitable for multiple packaging types and sizes, and can be tested simultaneously at multiple workstations;
Capable of detecting leakage apertures as low as 5 μ m;
19 inch embedded computer with touch function for easy operation and use;
Capable of storing 10000 pieces of test data;
Multi level permission management, flexible account settings;
A stable operating system;
● Can connect to a printer to print reports;
● Equipped with WIFI function;
Fast and efficient testing speed;
● Equipped with audit tracking function in accordance with 21CFR Part 11;
Medical Device Packaging Sealing Integrity Tester
Technical Specifications:
| indicator |
parameter |
真空度
|
-99Kpa |
| test cycle |
≥20s |
| operating interface |
19 inch touch screen |
| Sample quantity |
8 |
| operating system |
Windows 10 |
| Minimum detection limit |
≤5μm |
| shell |
Stainless steel/sheet metal |
| power supply |
AC220V±22V,50Hz |
| Device dimensions |
850mm (length) x 670mm (width) x 720mm (height) |
| weight |
120kg |
| warranty |
12 months |
Equipment operation:
Place the sample packaging into the testing chamber and then close the lid of the testing chamber. The experiment is divided into four testing stages
1Vacuum pumping stage:
Apply a predetermined level of vacuum to generate expansion and monitor throughout the entire testing cycle,
2Stable stage:
After reaching the set vacuum level, enter the stable equilibrium stage
3Attenuation testing phase:
Sensors will recognize small pressure changes. If the pressure decreases beyond the set value, the packaging will be classified as leaking
4Severe hole identification stage:
At the end of the attenuation phase, if the pressure is below the pre-set level in the testing method, the package will be classified as a severe leak.