E-mail
sale@nuctest.com
-
Phone
18964836057
- Address
Shanghai Minghe Instrument Co., Ltd
sale@nuctest.com
18964836057
Product Introduction:
NT8026The Type X scintillation continuous radon detector adopts the scintillation measurement principle, and the product complies with the measurement principles and requirements of GB50325-2020 "Standard for Indoor Environmental Pollution Control of Civil Building Engineering" and GB/T16147-1995 "Measurement Method for Radon Concentration in Air by Scintillation Bottle". It can be used for environmental air monitoring and analysis, radiation protection, nuclear accident monitoring, radiation dose evaluation, earthquake prediction, and teaching in colleges and universities.
Features:
1Adopting the free diffusion scintillation method, it has high sensitivity and strong anti-interference ability.
2Small size, light weight, suitable for continuous monitoring of environmental locations.
3High sensitivity, capable of measuring lower radon concentrations;
4The average radon concentration measured continuously can be obtained as quickly as 10 minutes, with the average value refreshed every minute.
5485 communication interface, MODBUS standard communication protocol, can be connected to computers, PLCs, etc., and can convert other communication methods.
Technical Specifications:
◎Detector: scintillation detector.
◎ Measurement range: (5-10000) Bq/m3
◎ Detection limit: 5Bq/m3;
◎ Uncertainty rate: not exceeding 15% (k=2)
◎ Response time: 30 minutes can provide measurement results, with a fastest response time of 10 minutes.
◎ Gas extraction method: free diffusion type
◎ Data calculation: Automatically calculate the concentration of a single measurement result/average measurement result
◎ Data storage: Measurement results are automatically saved and can store 19999 sets of data
◎ Working environment: Temperature ranges from -15 ℃ to 40 ℃, humidity is ≤ 95% RH
◎ Power supply: DC 9V-24V
◎ Dimensions: (128 * 97 * 84) mm
◎ Instrument weight: approximately 0.5kg
Product configuration:Radon detector, communication connection line
Features:
1Adopting the free diffusion scintillation method, it has high sensitivity and strong anti-interference ability.
2Small size, light weight, suitable for continuous monitoring of environmental locations.
3High sensitivity, capable of measuring lower radon concentrations;
4The average radon concentration measured continuously can be obtained as quickly as 10 minutes, with the average value refreshed every minute.
5485 communication interface, MODBUS standard communication protocol, can be connected to computers, PLCs, etc., and can convert other communication methods.