German DECKMA water oil analyzer OMD-32
The German DECKMA OMD-32 online water oil monitoring instrument and infrared water oil analyzer combine the technology of the previous OMD series industrial water oil measuring instrument and 15ppm oil concentration alarm instrumentIt has special performance that far meets the requirements of MEPC.107 (49) of the International Maritime Organization (IMO).
The OMD-32 online oil measuring instrument has a wide measurement range of up to 200ppm, with data recording function and a storage capacity of not less than 18 months; Having 2The factory default setting is 10ppm alarm point, and other settings (such as 100ppm) can be adjusted through the operation buttons on the panel. If it exceeds the reportAt the alarm set point, the alarm indicator light will light up and the corresponding relay will activate. In the event of a system malfunction, the system LED indicator will flash greenThe color turns into a constantly bright red, and at the same time, the system fault relay will activate.
It has internal testing function, which can manually test the alarm relay and perform functional testing on the desiccant.
The programmable 0 (4) -20mA signal output can be used for recorders or other external instruments.
correct
The 15ppm cabin alarm produced according to MEPC. 107 (49) is used to check for instrument drift, repeatability of instrument readings, and zero pointExternal inspection is not allowed to be corrected arbitrarily. For this reason, the instrument is sealed by electronic circuitry, so only the manufacturer or their authorized person (s) can install itOnly with relevant tools can calibration be carried out. OMD-32 can confirm whether the drift of the instrument is within the technical specifications through zero point detection.
zero adjustment
Connect oil-free water into the instrument for a few minutes and confirm if the reading is within the range of 0-2ppm. If not, you can do so in the offset parameter section of the menuAdjust the zero point. Please clean the instrument properly before zero adjustment.
Functional Testing
The OMD-32 water oil measuring instrument provides a test button to automatically test the alarm situation. After pressing the test button, the instrument automatically reads from the simulated high concentrationStart to decrease until the actual measurement value is reached.
Connect oil-free water into the instrument for a few minutes and confirm if the reading is within the range of 0-2ppm. If not, you can adjust it in the offset parameter in the menuZero hour. Please clean the instrument properly before zero adjustment.
Data recording function
The OMD-32 data logger collects and stores the following information for at least 18 months:
-Date&Time
-IN1/2 working status on (1)/off (0)
-Alarm status 1/2 on (1)/off (0)
-Oil concentration (0-200ppm)
Automatic cleaning unit for measuring tank (optional)
The OMD-32 water oil measuring instrument can be equipped with an automatic cleaning unit for the measuring tank as needed. The automatic cleaning unit of the measuring tank can prevent contamination caused by the measuring tankThe instrument is malfunctioning. The automatic cleaning unit of the measuring tank is a cleaning valve unit that connects the measuring tank and the computer unit together. The cleaning brush is cleaned by airOperating in motion.
The DH77780 manual cleaning unit for measuring slots can also be separately selected. When cleaning the measuring slot with the manual cleaning unit, there is no need to remove the top cover of the measuring slot. QingWhen washing, connect the cleaning water and manually press the cleaning handle a few times. Regular use of this unit can prevent instrument malfunctions caused by contamination of the measuring slot.
Measuring principle
OMD-32 adopts advanced light scattering principle and super strong suspended solid concentration
Degree suppression technology, infrared light passes through the sample, and several optical sensors measure the sample
The light signal generated by the scattering and refraction of oil particles is processed and passed through the first step
The mathematical logic is used for calculation, and the displayed oil concentration value is not affected by the suspension in the sample
The impact of particles and turbidity.
If one alarm (factory set to 10ppm) occurs, there will be two oil level alarms
The relay will activate after a set delay time.
The microprocessor continuously monitors the composition of the sensor and the electronic unit connected to the sensor
The condition of the element ensures that the correction accuracy can be guaranteed even in long-term and extremely harsh environments.