On site heat transfer coefficient detector with 32 channels and 64 channels

NegotiableUpdate on 05/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Technical specifications Temperature range: -100.00~+100.00 ℃ Heat flow range: 0.002~4.5.000 mV and 0.002~45.000 mV Two levels of acquisition speed: 200ms/channel, related to parameters Resolution: Temperature: 0.01 Heat flow: 0.001mV Accuracy: Pt1000 Basic error less than ± 0.1 ℃ Heat flow meter: 0.001mV System acquisition uncertainty: Temperature less than ± 0.3 ℃, Heat flow less than 2 ‰ of the displayed value Working environment: Temperature: -20 ℃~50 ℃, Humidity: less than 90% R · H Output relay contact capacity: 250V AC, 2A (resistive load) Power supply: 160VAC~260VAC, 50Hz
Product Details

On site heat transfer coefficient detector

This instrument(SR70B)The heat flow meter method, which is currently supported by most experts, can be used for detection, and data can also be collected in the calibration hot box method for detection. This instrument(R70B)We have adopted the latest microcontroller system and instrument amplifiers with high stability, low drift, and low noise. At the same time, we use high-precision platinum resistors as temperature measuring elements and have developed control and acquisition software that can automatically collect and store data,Using computers to achieve automatic calculation and report generation functions.

TECHNICAL INDEX

Temperature measurement range: -100.00 +100.00

Heat flow range: 0.002 4.5.000 mVreach0.002 45.000 mVTwo levels

Collection speed:200ms /Each channel, along with Parameter related

resolving power: Temperature:0.01 Heat flow:0.001mV

Accuracy:Pt1000Basic error less than ±0.1 Heat flow meter:0.001mV

System collection uncertainty: Temperature less than ±0.3℃, heat flow is less than the displayed value2

Work environment: Temperature: -20~50℃, Humidity: less than90%R·H

Output relay contact capacity:250V AC2A(Resistive load)

electricity Source:160VAC260VAC50Hz

Equipment composition:

64One channel data acquisition device

Heat flow meter chip1Ten meter three core signal cable with strip, only used when in use2Core, another spare core

platinum8Supporting a ten meter four core signal cable


This instrument(SR70B)The heat flow meter method, which is currently supported by most experts, can be used for detection, and data can also be collected in the calibration hot box method for detection. This instrument(R70B)We have adopted the latest microcontroller system and instrument amplifiers with high stability, low drift, and low noise. At the same time, we use high-precision platinum resistors as temperature measuring elements and have developed control and acquisition software that can automatically collect and store data,Using computers to achieve automatic calculation and report generation functions.

Equipment composition:

64One channel data acquisition device

Heat flow meter chip1Ten meter three core signal cable with strip, only used when in use2Core, another spare core

platinum8Supporting a ten meter four core signal cable