The GC-H series ethylene oxide sterilizer is a computer-controlled fully automatic sterilization equipment developed and produced by our company. Its technical level and manufacturing process are leading in China. The product consists of a microcomputer control system, residual gas treatment device, and sterilization studio. When in use, simply press the run button twice to achieve complex processes such as automatic heating, vacuuming, vaporization, sterilization, and residue removal, which is very convenient and safe, with sterilization almost reaching 100%. At the same time, the ethylene oxide mixed gas used in the equipment has the characteristics of * flame retardant, * explosion-proof, * strong penetration, * high-efficiency broad-spectrum sterilization, * short sterilization time, * non corrosive, * non residual toxic, * non polluting the environment, etc. This product has unique advantages in sterilizing and disinfecting items that are sensitive to moisture and heat. At present, it is widely used in the fields of medical and health care, industry, foreign trade, commerce, banking, archaeology, archaeological archive management, and cultural relic management.
Main performance parameters of GC-H1000 ethylene oxide sterilizer equipment
1. Main parameters
Inner layer size: 1300X745X1080
Outer dimensions: 1600X1500X2100
Power supply: 380V, 18KW
Work pressure: -60KPa-0
2. Main configuration
| Serial Number | name | Related parameters | notes |
| 1 |
Box section (Main components) |
Inner liner: SUS304 stainless steel 2 Water jackets: Q235 material on both sides and top surface 3. Shell cladding: SUS304 stainless steel, δ=1mm 4. Insulation layer: Aluminum silicate cotton |
|
| 2 |
Door body part (Main components) |
1. Door body: SUS304 stainless steel 2-door frame: Material Q235 3 door sealing flanges: 304 4 Door gear strip: Q235 5 shell cladding: stainless steel δ=1.2mm 6 electric up and down movement rotary door, single door |
|
| 3 |
Control rack (Main components) |
1 rack: angle iron 2 Water tank: Q235 steel plate 3mm 3 Hot water circulation system (pipeline): galvanized pipe 4 Heater: U-shaped stainless steel seamless tube (9KW) |
|
| 4 | EO input port | Inside the cabinet, one EO is put in | |
| 5 | EO investment amount | EO input can be automatically controlled by pressure and weight; | |
| 6 | Temperature control in sterilization room |
Quantity: There are two temperature sensors installed on the box, one for monitoring and one for efficiency matching, and an independent ultra-high temperature alarm device is provided; According to the sterilization process requirements, it can be set arbitrarily between 0~80 ℃ |
|
| 7 | pressure control | There are two pressure sensors installed on the box, one for monitoring and the other for calibration, and an independent ultra-high pressure alarm device is provided | |
| 8 | Humidity control |
Install a humidity sensor on the box, one for monitoring. Humidity control humidification can be selected. Humidity control humidification is generally set between 30~70% RH, and can be set arbitrarily between 0~100% RH, automatically controlled. Pressure controlled humidification can rely on pressure changes to control humidification, and can automatically shield humidity values. |
|
| 9 |
automatic control EO input temperature and input amount |
Preset EO gasification temperature (45 ℃ -50 ℃) Weight can control the amount of EO input, and pressure can also control the amount of EO input |
|
| 10 |
Preheating/Analysis (Number of permutations) |
Introduce filtered air or inert gas to atmospheric pressure, then evacuate the sterilization chamber and repeat alternately multiple times | |
| 11 |
Preheating/Analysis (Time permutation) |
The method of continuously flowing filtered air through the sterilization chamber to remove ethylene oxide gas. | |
| 12 |
Computer fully automatic control Manually control two operating modes |
1. Human Computer Interaction Interface 2. Fully automatic control of sterilization process 3. Automatic alarm and automatic safety prompt |
| Serial Number | name | Related parameters | notes |
| 1 |
Box section (Main components) |
Inner liner: SUS304 stainless steel 2 Water jackets: 16 # channel steel Q235 material on both sides and top surface 3. Shell cladding: SUS304 stainless steel, δ=1.2mm 4 Foot: Channel steel 16 #/Q235 5 Foot support: Steel plate 10/Q235 6 Insulation layer: Combustion supporting polystyrene |
|
| 2 |
Door body part (Main components) |
1. Door body: SUS304 stainless steel 2-door water jacket: 16 # channel steel Q235 material 3 door frame: rectangular steel 100 × 60.Q235 4 door sealing flanges: steel plate 60/Q235 5-door guide rail trailer: rectangular steel 80 * 60/Q235 6 door body guide rails: pipe diameter 28 × 4/Q235 7 hooks: Q235 8. Shell cladding: SUS304 stainless steel, δ=1.2mm 9. Insulation layer: Aluminum silicate fiber blanket 10 Pneumatic sliding door, single door, automatic door opening and closing. |
|
| 3 |
Control rack (Main components) |
1 rack: angle 5100cm × 800cm × 150cm 2 Water tank: SUS304 steel plate 3mm 3 Hot water circulation system (pipeline): galvanized pipe 4 Heater: U-shaped stainless steel seamless tube (9KW) |
|
| 4 | vaporizer |
1. Heating inner cylinder: SUS304 steel plate with a diameter of 250 × 4 2 EO pipes: φ 22 × 2 pipes/stainless steel 3. Insulation outer cylinder: stainless steel 4. Insulation layer: Aluminum silicate fiber blanket |
|
| 5 | EO input port | Inside the cabinet, 2 EO inputs are needed | |
| 6 | EO investment amount | EO input can be automatically controlled by pressure and weight; | |
| 7 | Temperature control in sterilization room |
Quantity: There are two temperature sensors installed on the box, one for monitoring and one for efficiency matching, and an independent ultra-high temperature alarm device is provided; According to the sterilization process requirements, it can be set arbitrarily between 0~80 ℃ |
|
| 8 | pressure control | There are two pressure sensors installed on the box, one for monitoring and the other for calibration, and an independent ultra-high pressure alarm device is provided | |
| 9 | Humidity control |
Install a humidity sensor on the box, one for monitoring. Humidity control humidification can be selected. Humidity control humidification is generally set between 30~70% RH, and can be set arbitrarily between 0~100% RH, automatically controlled. Pressure controlled humidification can rely on pressure changes to control humidification, and can automatically shield humidity values. |
|
| 10 |
automatic control EO input temperature and input amount |
Preset EO gasification temperature (45 ℃ -50 ℃) Weight can control the amount of EO input, and pressure can also control the amount of EO input |
|
| 11 |
Preheating/Analysis (Number of permutations) |
Introduce filtered air or inert gas to atmospheric pressure, then evacuate the sterilization chamber and repeat alternately multiple times | |
| 12 |
Preheating/Analysis (Time permutation) |
The method of continuously flowing filtered air through the sterilization chamber to remove ethylene oxide gas. | |
| 13 |
Computer fully automatic control Manually control two operating modes |
1. Human Computer Interaction Interface 2. Fully automatic control of sterilization process 3. Automatic alarm and automatic safety prompt |