-
E-mail
13861020896@163.com
-
Phone
13861020896
-
Address
No.1 Lantian Road, Zhenglu Heping Industrial Park, Tianning, Changzhou, Jiangsu
Changzhou Yueheng Instrument Co., Ltd
13861020896@163.com
13861020896
No.1 Lantian Road, Zhenglu Heping Industrial Park, Tianning, Changzhou, Jiangsu
Purging deviceIt is composed of a rotor flowmeter and a constant flow valve, and is suitable for inlet orWhen there is a certain fluctuation in outlet pressure, achieve flow measurement and ensure a constant output of flow. extensiveUsed for blowing transmitters in industries such as chemical, petroleum, metallurgy, and steel, as well as for various other applicationsProcess control of analytical instruments, flushing of orifice pressure taps, and differential pressure liquid level measurement.Assemble the flowmeter, filter pressure reducing valve, and pressure gauge on one panel, as the groupAll components are assembled on the panel, making it easy to install. When the outlet pressure fluctuates, it can be maintainedStable blowing (air) flow rate to form a panel type blowing device.
Product Features
◆ Diverse forms: single channel, dual channel, multiple channel blowing
◆ Various installation methods: panel installation, cabinet installation
◆ Connection method: 1/4'NPT, sleeve connection, threaded connection, flange connection
Corrosion performance: good
technical indicators
Control and measurement range: water at 20 ℃, 0.15~160L/h,
Gas at 20 ℃, 101325Pa; 3~4300L/h
Range ratio: 10:1
Accuracy level: 4.0
◆ Maximum pressure: 1.6MPa
◆ Maximum temperature: -80~150 ℃
◆ Material: 304SS 316SS
◆ Seal: PTFE
◆ Process connection: Standard card sleeves: Ø 6, Ø 8, Ø 10
Standard thread: 1/4'NPT 1/2'NPT
Standard flange: HG20592-2009 or ANSI 150LB
Special: According to user requirements
◆ Adjustment performance: Input pressure variation ± 10%;
Output flow change less than ± 1%
Product selection:

flow range

installation dimensions




Installation of blowing device
Please choose a suitable location to install the flow blowing device to ensure easy adjustment, cleaning, and disassembly of the flow meter blowing device.
Due to the installation of a magnetic coupling transmission system on the float flowmeter of the purging device (flowmeter). Therefore, ensure that the interference magnetic fields generated by other work equipment do not affect
The measurement results of the sound flow meter.
During installation, it is necessary to ensure the stability of the flow blowing device, and fixed brackets should be added at appropriate positions
The installation size should not exceed the given size too much or too little to avoid tensile and compressive forces acting on the flow device.
When the liquid medium contains ferromagnetic particles, it is necessary to filter out the magnetic particles in the instrument.
Be sure to ensure that the fluid direction of the medium is the same as the direction required by the flow blowing device. When installing the instrument, all fine tuning needle valves should be closed
Measurement of liquids
Before operation, please empty and blow clean the pipeline to avoid any impact.
Please slowly open the valve.
Measurement of gases
Please slowly open the valve to adjust the pressure to the working pressure.
Basically, the flow rate should be changed by adjusting the opening of the valve to prevent the float from suddenly accelerating, surging, and hitting the limiter (such as in the case of using an electromagnetic)
At this point, the measuring components may be damaged.