E-mail
hsykj816@163.com
-
Phone
13501013681
-
Address
4th Floor, Beixin Building, Jinzhuang No.1 Courtyard, Haidian District, Beijing
Beijing Huiyuiyuan Environmental Technology Co., Ltd
hsykj816@163.com
13501013681
4th Floor, Beixin Building, Jinzhuang No.1 Courtyard, Haidian District, Beijing
Technical features:
Pump blockage or idle automatic monitoring systemThe pump controlled by an intelligent computer program can maintain a constant sampling speed under the action of air resistance. Especially when the filter is partially clogged, the pump sampling speed can still remain constant.
M21 method failure protection functionCombined with Cal5.0 calibration software, programmable detection can be achieved. Without proper calibration of Phx42 by the testing personnel, the equipment will not be able to perform testing normally.
Instrument self diagnostic functionThe instrument motherboard automatically records and generates data files every 2 seconds, automatically recording voltage, high/low voltage hydrogen status ppm、 Pump power, exhaust pressure, and thermocouple temperature. SDK can also be obtained from public platforms.
batteryThe battery has undergone further technological innovation and comes with a one-year warranty.
Filter self-test functionPhx42 can automatically detect whether the filter is in place. If the filter is lost or not installed, the device control end will automatically sound an alarm and force it to stop continuing detection.
portabilityPhx42 is designed to be smaller in size and lighter in weight. Testing personnel find it more convenient to use.
Application areas:
Phx42 can be used for collecting safety data in Class 1 and Division 1 hazardous areas. include:
1. Refineries and chemical plants
2. Natural gas or oil pipelines
3. Compressor and pump station
4. Oilfield production facilities
5. Any location where VOCs are present
6. Indoor and outdoor environment
Product parameters:
Measurement range: 1.0~100000ppm
Accuracy: ± 10% of the reading
Certification level:
Class I, Division 1, Groups A, B, C, D, T3 ( Per UL and CSA deviations)
Class I, Zone 1 AEx db ia IIC T3 Gb
CE0359 EXII 2G
Ex db ib IIC T3 Gb
AEx db ib IIC T3 Gb
-20°C ≤ Tamb ≤+40°C
Product specifications:
Weight: 3.6 Kg
Size: 25.4cm × 5.49cm × 19.05cm
Battery usage time: 10+hours
Hydrogen usage time: 10+hours
Design features:
Faster response time
More lightweight
PDA wireless control
Built in Bluetooth module
FID single detector
Automatic reignition
Durable flame retardant plug component
Replaceable battery
Single sided interface design
The most advanced self checking diagnostic system provides real-time protection for instruments