Overview
The YD-2 Plant Oil Smoke Point Tester is a specialized instrument developed based on the national standard GB/T20795-2006 "Determination of Plant Oil Smoke Point", Article 4 "First Method Automatic Tester Method", for measuring the smoke point of plant oil. It is suitable for quality supervision, import and export inspection, oil processing, oil storage and transportation, food processing, scientific research, agricultural breeding, schools and other departments that need to measure the smoke point of plant oil
Product Details
Plant oil smoke point testerYD-2 is a specialized instrument developed in accordance with the national standard GB/T20795-2006 "Determination of Smoke Point of Plant Oils and Fats", Article 4 "First Method Automatic Measuring Instrument Method", for measuring the smoke point of plant oils and fats. It is suitable for quality supervision, import and export inspection, oil processing, oil storage and transportation, food processing, scientific research, agricultural breeding, schools and other departments that need to measure the smoke point of plant oils and fats.
Plant oil smoke point testerAfter the YD-2 sample is heated, smoke is generated. The first continuous blue smoke produced enters the photoelectric smoke detector and reacts with the light emitted by the detector, causing the detector to respond and accurately measure the smoke point.
Plant oil smoke point testerYD-2 adopts an upper and lower box structure, with an open flue, overcoming the problem of photoelectric smoke detectors being easily contaminated by oil fumes. The instrument consists of a heater, smoke collector, photoelectric smoke detector, temperature sensor, control and compensation circuit, system control software, automatic elevator, etc. The measurement process and results are displayed and recorded on the computer throughout the process.
Plant oil smoke point testerYD-2 Technical Parameters 1. Program heating: After rapidly heating the sample to 150 ℃, heat it at a rate of (5-6) ℃/min 2. Wavelength range of photoelectric smoke detector: 380nm~780nm 3. Detector sensitivity: Response current>80 μ A 4. Temperature sensor: A-grade Pt100 platinum resistor, calibrated at the factory 5. Double experimental error: ≤ 2 ℃ 6. Output mode: computer storage, display, printing, including USB interface 7. Working environment: temperature (10-35) ℃, air pressure: (70-106) kPa, humidity: 45% -75% 8. Power Supply and Power: AC (220 ± 10) V, 50Hz, 400W (during heating) 9. Dimensions and weight: 490 × 360 × 270 (L × W × H) mm, 18kg
|