Precision digital pressure gauge, level 0.02
I. Overview
1. Multi functional instrument, capable of measuring pressure while measuring ± 25mADC current or ± 50VDC voltage, pressure switch testing and automatic recording of pressure switch values, with 24VD output, can be used as a power supply for 4-20mA two-wire transmitters, and has the function of recording large and small values.
2. Using a 24 bit high-performance A/D converter combined with a high-performance microprocessor to continuously adjust the various performance and technical indicators of the instrument, ensuring that the instrument can be used over a wide temperature range for a long time without affecting its accuracy.
3. Low power consumption, the battery adopts imported high-energy lithium batteries, with a stainless steel casing, beautiful appearance, sturdy and durable, and strong anti-interference ability.
4. Intelligent charging, with automatic shutdown and protection functions for battery overcharging and undervoltage. The low-power shutdown protection function protects the instrument from battery energy damage when not in use for a long time, ensuring the longevity of the battery.
5. Ultra high resolution 1:1000000, continuous display without broken codes or text jumping phenomenon.
6. Adopting thin film panels and imported tactile switches, the style is novel and the button life is long.
7. Backlit LCD multi-channel display with low power consumption and long lifespan.
8. The digital calibration of pressure, current, and voltage does not require any hardware adjustment, and can be directly operated on the panel to calibrate zero and full range.
9. Built in six digit high-precision DC digital voltage and current meter.
10. Equipped with RS-232 or RS-485 interfaces, it can communicate with the upper computer, transmit real-time measurement data to the calibration software, record data, automatically generate tables, calculate errors, and store and print calibration data. Can calibrate pressure transmitters, pointer pressure gauges, pressure switches (pressure controllers), etc.
Precision digital pressure gauge, level 0.02
2、 Purpose:
HS-YBS-YEPressure switch calibratorIn addition to being used as a high-precision calibration standard (meter), it can also be used as an on-site calibration instrument, widely used in metallurgy, petroleum, chemical, power, natural gas, metrology, and scientific research departments.
3、 Working principle
1. Principle diagram

2. Working principle
a、 Pressure: The measured medium is applied to a solid-state (silicon diaphragm) sensor from a pressure tube. When the pressure changes, the resistance of the diffused silicon diaphragm changes under the pressure resistance effect. This change is detected as an electrical signal and converted into a voltage signal proportional to the pressure through a circuit. The signal is converted into a digital signal by a 24 bit analog-to-digital converter, processed by a microprocessor, and displayed on an LCD display as the numerical value of the measured medium pressure.
b、 Current and Voltage: When a random pair of probes are inserted into the corresponding socket on the instrument panel, the instrument can be turned on and switched to the current or voltage mode for measurement. The measured data is collected by a 24 bit A/D converter and sent to a microprocessor for linear, temperature, and full-scale processing. The measured value is then displayed on the LCD screen.
4、 Technical instructions
1. Pressure range: -0.1~60MPa (range selection is shown in the attached table). Multiple intelligent digital pressure modules can also be optionally selected, with no limit on quantity and range, and automatic recognition for easy use (module selection is shown in the attached table). Gauge pressure, absolute pressure, or differential pressure measurement can be selected, which can be used in conjunction with manual pumps or pressure calibrators to calibrate pressure transmitters, spring tube pressure gauges, pressure switches, etc.
2. Resolution: Pressure: Min 0.01Pa~0.1kPa, determined according to the range.
Current: 0.1 μ A Voltage: 0.1mV
3. Current measurement range: ± 25.000mA, voltage measurement range: ± 50.0000 V
4. DC power output: 24VDC ± 10%, high load current: 50mA
5. Accuracy: Pressure: 0.05% F • S 0.02% F • S
Voltage and current: ± (0.01% R.D+0.005% F • S)
6. Temperature range: 0-50 ° C, ensuring instrument accuracy within the 0-50 ° C range
7. DC working time: ≥ 80 hours, depending on the working conditions
8. Display: Press the button to select 5 or 6 digits for display
9. Relative humidity: ≤ 80% RH
10. Overload capacity: 1.2-1.5 times the upper range limit
11. Dimensions: Instrument outer diameter 100mm, thickness 50mm (sensor nozzle outer diameter 29mm, length 73mm)
12. Weight: 620g
13. Power supply: 3.7V/3000mAh lithium battery, charging voltage 5V, with battery level display function, easy to understand battery usage
14. Pressure medium: In general, the pressure medium within the range of -100 to 250kPa can only be non corrosive gas. Within the range of 0.4 to 60MPa, the pressure medium is a liquid (gas) compatible with 316L stainless steel. It can also be calibrated with gas within the range of -100kPa to -16000kPa using various range prohibited oil pressure gauges
5、 Precautions0.02% precision digital pressure gauge 0.02%
1. When the instrument is not in use, the power should be turned off. If it is not in use for a long time, it should be discharged and charged once every three months.
2. The instrument has sufficient overload capacity, but do not overload it severely, otherwise it will cause damage to the instrument sensor and render the instrument unusable.
3. Instrument sensors belong to high-precision products, and the surface of the silicon diaphragm should not collide with solids, otherwise it will damage the sensor.
4. Without professional testing skills and equipment, do not open the chassis for maintenance, and do not adjust internal components or replace materials, otherwise the reliability of the instrument cannot be guaranteed.

0.02% precision digital pressure gauge 0.02%Module selection table (special ranges can be customized)
model |
range |
accuracy |
model |
range |
accuracy |
DPM01 |
-100~0KPa |
0.05%F•S 0.02%F•S |
DPM15 |
0~600KPa |
0.05%F•S 0.02%F•S |
DPM02 |
-100~100KPa |
DPM16 |
0~1MPa |
||
DPM03 |
-60~60KPa |
DPM17 |
0~1.6MPa |
||
DPM04 |
-25~25KPa |
DPM18 |
0~2MPa |
||
DPM05 |
-10~10KPa |
DPM19 |
0~2.5MPa |
||
DPM06 |
-6~6KPa |
DPM20 |
0~4MPa |
||
DPM07 |
-4~4KPa |
DPM21 |
0~6MPa |
||
DPM08 |
0~25KPa |
DPM22 |
0~10MPa |
||
DPM09 |
0~40KPa |
DPM23 |
0~16MPa |
||
DPM10 |
0~60KPa |
DPM24 |
0~20MPa |
||
DPM11 |
0~100KPa |
DPM25 |
0~25MPa |
||
DPM12 |
0~160KPa |
DPM26 |
0~30MPa |
||
DPM13 |
0~250KPa |
DPM27 |
0~40MPa |
||
DPM14 |
0~400KPa |
DPM28 |
0~60MPa |
Attachment: Range selection (special ranges can be customized)
range |
Accuracy (F • S) |
range |
Accuracy (F • S) |
||
-100~100KPa |
0.05% |
0.02% |
0~600KPa |
0.05% |
0.02% |
-60~60KPa |
0.05% |
0.02% |
0~1MPa |
0.05% |
0.02% |
-25~25KPa |
0.05% |
0.02% |
0~1.6MPa |
0.05% |
0.02% |
-10~10KPa |
0.05% |
0.02% |
0~2MPa |
0.05% |
0.02% |
-6~6KPa |
0.05% |
0.02% |
0~2.5MPa |
0.05% |
0.02% |
-4~4KPa |
0.05% |
0.02% |
0~4MPa |
0.05% |
0.02% |
0~25KPa |
0.05% |
0.02% |
0~6MPa |
0.05% |
0.02% |
0~40KPa |
0.05% |
0.02% |
0~10MPa |
0.05% |
0.02% |
0~60KPa |
0.05% |
0.02% |
0~16MPa |
0.05% |
0.02% |
0~100KPa |
0.05% |
0.02% |
0~25MPa |
0.05% |
0.02% |
0~160KPa |
0.05% |
0.02% |
0~35MPa |
0.05% |
0.02% |
0~250KPa |
0.05% |
0.02% |
0~40MPa |
0.05% |
0.02% |
0~400KPa |
0.05% |
0.02% |
0~60MPa |
0.05% |
0.02%
|