Precision machining cleanliness test dust particle counter 3718-A

satisfyJIS9921TheISO21501-4andISO14644-1:2015Standard. Two Design Sciences,Small and compact products,Using external air source,Built in pressure sensor,Ensure traffic flow28.3L/minConsistency and stability;Using long-life laser diodes,Capable of precise testing0.3、0.5and5.0MmWaiting for particles;adopt316Stainless steel shell and protective box with sealing treatment, Having resistanceVHPAnd functions such as alcohol vapor,have2000Group data cache,Data redundancy backup function,Avoid losing test data due to system failure or power outage;Simultaneously possessing standardsModbustAgreement and4~20 mAAnalog output function,Compatible with monitoring systems,widely usedGMPcontrol area,quarantine zone/system(RABS)Theclean room、Laboratory or industrial applications,Realize intelligent control,Real time monitoring of changes in the concentration of dust particles in the production process within the clean production area,Verify the number of dust particle concentrationsyesDoes it meet the requirements of production quality control.
Cleanliness testingRemote particle counter3718-A/3719-A
Having standardsModbusAgreement and4~20mAAnalog output function;
Simultaneous testing of two particle sizes0.3The0.5Mmor0.5The5.0Mm;
Using a long-life laser light source,Average running time≥10Year3year warranty;
have2,000Group test data cache、Data redundancy backup function,Even in the event of system failures such as power outages,The monitoring data before the fault will be stored in the monitoring system database first after the system is restored,Ensure that monitoring data is not lost and has traceability;
adopt316Stainless steel shell and protective box with sealing treatment,Having resistanceVHPAnd functions such as alcohol vapor;
Can output monitoring data, operating status, and alarms;
adoptPOEpower supply,Support hot swapping,easy to maintain,cost savings;
type number |
3718-A |
3719-A |
|
grain path |
0.3The0.5Mm |
0.5The5.0Mm |
|
flow quantity |
28.3L/min(1CFM) |
||
light source |
Long life laser diode |
||
Counting efficiency |
comply withISO21501-4,JIS B9921 |
||
Maximum detectable concentration |
500,000CNT/ft3 |
||
Parameter Settings |
sampling time |
1~60S |
|
output range |
(Each particle size is set separately) number:0~10CNTThe0~100CNTThe0~1,000CNTThe0~10,000CNT Concentration:0~10CNT/cfThe0~100CNT/cfThe0~1,000CNT/cfThe0~1000,000CNT/cf 0~353CNT/m3The0~3,530CNT/m3The0~35,300CNT/m3The0~35,300,000CNT/m3
|
||
report police |
0%~100% |
||
alarm output |
ON/OFF |
||
land address |
0~512 |
||
communication interface |
RS485, analog output4~20mA |
||
communication protocol |
RS485TheModbus(RTU)TheModbus(TCPTheIP) |
||
working air source |
External air source |
||
data caching |
2,000group |
||
Operating language |
English and Japanese |
||
environment |
operation |
10~30℃20~85%RH(No condensation) |
|
save |
-10~50℃95%RHBelow (without condensation) |
||
electricity source |
DC 9~28VThePOEpower supplyAC 100~240V |
||
Overall dimensions |
133x95x80mm |
||
heavy quantity |
1.0kg |
||
Standard Appendix |
ACAdapter, user manual, constant velocity suction port, zero count filter |
||