E-mail
1832549464@qq.com
-
Phone
18352321309
-
Address
No. 188, Jinhu County Industrial Park, Huai'an City, Jiangsu Province
Jiangsu Jianheng Instrument Co., Ltd
1832549464@qq.com
18352321309
No. 188, Jinhu County Industrial Park, Huai'an City, Jiangsu Province
Overview of Heavy Oil Level Gauge ProductsPrice of heavy oil level gauge
The heavy oil level gauge is a product developed and produced by our company by introducing and absorbing similar foreign products, and absorbing, digesting, and improving them according to the magnetic level gauge standard T21584-95 issued by the former Ministry of Chemical Industry. It can be used for medium level detection of various towers, tanks, spherical containers, boilers and other equipment. This series of magnetic level gauges can achieve high sealing, leak prevention, and adapt to liquid level measurement under high pressure, high temperature, and corrosive conditions, with reliable safety. It makes up for the shortcomings of glass plate (tube) level gauges, such as unclear indication and easy breakage, and is not affected by high and low temperature fluctuations, without the need for multiple sets of level gauge combinations. The entire measurement process has no blind spots, with clear display, intuitive readings, and a large measurement range. Especially for the on-site instructions, as they do not come into direct contact with liquid media, they are more effective against high temperature, high pressure, high viscosity, toxic and harmful, and highly corrosive media. Therefore, it has higher reliability, safety, reliability, and practicality than traditional glass tubes and plate level gauges. The digital signal processing technology used in the heavy oil level gauge avoids the influence of container wall thickness and achieves true non-contact measurement of the liquid level height inside the sealed container outside the tank. The sonar sensor (probe) is installed directly below the outer wall (bottom) of the tested container, without the need to open holes in the tested container. It is easy to install, enables online installation and debugging, and does not affect production. It can measure the liquid level of various flammable, explosive, toxic and other hazardous media, strong acids, strong alkalis and various pure liquids in high-temperature and high-pressure sealed containers.
Price of heavy oil level gauge
The significant feature of heavy oil level gauges is the isolation between the liquid medium and the indicator, making them very safe, reliable, and durable in any situation. Moreover, various models of level gauges are equipped with level alarms and control switches, which can achieve upper and lower limit over limit alarms, control, or interlocking of the level or boundary; Equipped with a static pressure level transmitter or a dry spring resistance level transmitter, the liquid level and boundary signals can be converted into a two-wire 4-20mADC standard signal, enabling remote indication, detection, recording, and control. Suitable for liquid level measurement in corrosive media and high operating temperatures, with reliable structure and long service life. It is the best choice for measuring the liquid level of highly corrosive media such as nitric acid. Tailored for customers with low temperature and pressure requirements, our PP material level gauge can be used. This series of heavy oil level gauges can be widely used for level measurement and control in various industries such as power, petroleum, chemical metallurgy, environmental protection, shipbuilding, construction, and food production processes.
Users can use remote transmitters according to engineering needs, which can achieve local digital display and output standard remote transmission electrical signals of 4-20mA to meet the needs of recording instruments or industrial process control. It can also be used in conjunction with magnetic control switches or proximity switches to monitor liquid level alarms or control inlet and outlet equipment.
Working principle of heavy oil level gauge
The heavy oil level gauge adopts the principle of sonar ranging, using a probe attached to the outside of the container wall to collect sonar signals. With sonar wave processing technology as the system core and high-speed signal processing technology of *, the algorithm of Shaanxi Acoustic Science is used to calculate the liquid level inside the container. The calculated liquid level value is displayed locally and outputs a remote transmission signal. The instrument can output measurement results to the control center through (4-20) mA analog signals, HART, RS-485 and other interfaces, and can also be debugged online through HART, RS-485, infrared and other interfaces.
Product features of heavy oil level gauge
1. Wide applicability and diverse installation forms, suitable for measuring liquid levels and interfaces of any medium.
2. The tested medium is isolated from the indicator structure, with good sealing performance, leak prevention, and adaptability to liquid level measurement under high pressure, high temperature, and corrosive conditions, with high reliability.
3. It integrates on-site indication, remote transmission, and alarm control, and can be freely adjusted. It has complete functions, dual color indication with night light, continuous and intuitive, eye-catching, and a large measurement range. The observation direction can be changed arbitrarily.
4. Good vibration resistance, able to adapt to large liquid level fluctuations, simple working structure, easy installation, and low maintenance costs.
5. Equipped with exquisite magnetic steel calibrators, technical parameters can be adjusted on-site at will.

Technical parameters of heavy oil level gauge
1、 Display some technical parameters
1. Measurement range: 300~10000mm
2. Accuracy: ± 10mm
3. Flip column diameter: 10mm
4. Work pressure: Standard type ≤ 2.5Mpa
5、UPVG≤0.6Mpa
6. Medium density: ≥ 0.45gcm3
7. Medium temperature: ordinary type: -20 ℃
8. High temperature type:<250 ℃
9. Medium density difference: 0.15g/m3 (measurement interface)
10. Medium viscosity: ≤ 0.4PaS
11. Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm Follow speed: ≤ 0.08m/s
12. Connecting flange: compliant with GB standards.
2、 Technical parameters of the remote transmission part of the transmitter
1. Model: Regular Type: BS
2. Explosion proof type: FBB Ex
3. Power supply voltage: 24VDC (2-wire system)
4. Accuracy: ± 1.5% FS (H ≥ 1000mm) ± 2.5% FS (H<1000mm)=Output current: 4~20mA Load capacity: 600
5. Working temperature: -20 ℃~55 ℃
6. Protection level: IP65 Explosion proof type: dIIBT4
7. Cable interface: ordinary type: Pg11
8. Explosion proof type: M20x1.5 internal thread

Correct assembly, use and maintenance of heavy oil level gauge
1. Magnetic substances are not allowed to approach the body of the heavy oil level gauge, and iron wire fixation is prohibited, otherwise it will affect the normal operation of the heavy oil level gauge;
2. When users use heat tracing pipelines themselves, non-magnetic materials such as copper pipes must be selected. The heat tracing temperature is determined based on the condition of the medium;
3. The installation of heavy oil level gauge must be vertical, and a ball valve should be installed between the heavy oil level gauge and the container inlet pipe for easy maintenance and cleaning;
4. The medium should not contain solid impurities or magnetic substances to avoid jamming the float;
5. Before use, use a calibrated magnetic steel to place the small balls below zero position in red and the other balls in white;
6. Open the bottom flange and install the magnetic float (note: the heavy end with the magnetic end is facing upwards and cannot be inverted);
8. According to the condition of the medium, the main pipe should be cleaned irregularly to remove impurities;
9. For level gauges that exceed a certain length (ordinary type>3 meters, anti-corrosion type>2 meters), it is necessary to add a middle reinforcement flange or ear hook as a fixed support to increase strength and overcome its own weight;
10. The installation position of the heavy oil level gauge should avoid or be far away from the inlet and outlet of the material medium to avoid rapid changes in the local area of the material fluid, which may affect the accuracy of the level measurement;
11. When equipped with remote transmission instruments, the following measures should be taken:
(1) The remote transmission supporting instruments should be tightly attached to the main pipe of the liquid level gauge and fixed with stainless steel clamps (iron is prohibited);
(2) The sensing surface on the remote transmission supporting instrument should face and be closely attached to the main tube;
(3) The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indication of the liquid level gauge;
(4) The connection between remote transmission supporting instruments and display instruments or industrial control computers should be separately laid in protective tubes or shielded two core cables;
(5) After the wiring holes of the junction box are laid, it is required to be well sealed to prevent rainwater, moisture, etc. from entering and causing the remote transmission supporting instruments to not work properly. The junction box should be promptly covered after maintenance or debugging is completed.

Application and Scope of Heavy Oil Level Gauge
type |
model |
Scope and Application |
普通型 |
UHZ - P |
Ordinary float level gauge is a type of on-site display instrument widely used in petroleum, chemical, power, light industry, environmental protection and other departments to continuously display the liquid level in open or pressure vessels. |
corrosion-resistant type |
UHZ - F |
Especially suitable for liquid level measurement indicators with corrosiveness and toxicity (working pressure ≤ 1.6MPa); Measurement range ≤ 2m). |
Heat tracing type |
UHZ- R |
Suitable for measuring liquid media with high viscosity, high or low temperature (this instrument requires the use of a heat tracing device). |
high-temperature type |
UHZ- T |
Suitable for continuous liquid level measurement of liquid media with container pressure less than 10Mpa and temperature between 200 ℃ and 450 ℃. |
High voltage type |
UHZ- Y |
Suitable for measuring the liquid level of liquid media in closed containers with temperatures below 200 ℃ and process pressures above 10Mpa (below 20Mpa). |
High temperature and high pressure type |
UHZ- H |
Suitable for measuring the liquid level of liquid media in closed containers with temperatures above 200 ℃ and process pressures above 10Mpa (below 20Mpa). |
Explosion-proof type |
UHZ -B |
This instrument is suitable for situations where remote transmission of electrical signals is required in flammable and explosive environments. It comes with electronic devices such as 4mA to 20mA current signals or liquid level transmitters with upper and lower limit alarm settings. |
Top mounted type |
UHZ -D |
Suitable for various underground fluid storage tanks, it can display liquid level on the ground. Not suitable for working environments with strong vibrations and strong magnetism (working pressure ≤ 1.6MPa); Measurement range ≤ 2m). |
Type spectrum of heavy oil level gauge
UHZ |
|
|||||||||||||
|
code name |
meaning |
T |
high-temperature type |
Basic Types |
|||||||||
|
P |
普通型 |
Y |
High voltage type |
||||||||||
|
D |
Top mounted type |
H |
High temperature and high pressure type |
||||||||||
|
F |
corrosion-resistant type |
B |
Explosion proof type (Bd is explosion-proof type, Bi is intrinsic safety type) |
||||||||||
|
R |
Heat tracing type |
|
|
||||||||||
|
code name |
meaning |
4 |
4.0 |
process pressure (MPa) |
|||||||||
|
0 |
atmospheric pressure |
5 |
6.3 |
||||||||||
|
1 |
1.0 |
6 |
10.0 |
||||||||||
|
2 |
1.6 |
7 |
15.0 |
||||||||||
|
3 |
2.5 |
8 |
other |
||||||||||
|
code name |
meaning |
4 |
0.75-0.9 |
medium density (g∕cm3) |
|||||||||
|
1 |
0.45-0.51 |
5 |
0.9-1.0 |
||||||||||
|
2 |
0.51-0.65 |
6 |
1.0-1.8 |
||||||||||
|
3 |
0.65-0.75 |
|
|
||||||||||
|
code name |
meaning |
2 |
PVC/ UPVC |
Main material |
|||||||||
|
0 |
304 |
3 |
Lining F4 (or PE) |
||||||||||
|
1 |
316/ 316L |
4 |
other |
||||||||||
|
0 |
Column flipping on-site display type |
display mode |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Main technical indicators
1. Range (mm): 299-80999
2. Medium density (g/cm3): 0.49-1.99
3. Medium viscosity: ≤ 0.019Pa. S
4. Working temperature ℃: -39.9~349.99
5. Pressure rating (MPa): ≤ 31.99
6. Measurement accuracy (mm): ≤± 9.99
7. Installation methods: side mounted, top mounted, bottom mounted
8. Protection level: IP64.99
9. Explosion proof level: ib Ⅱ CT4 (intrinsic safety type), d Ⅱ BT4 (explosion-proof type)
10. Transmission mode: 4-20mA or switch quantity
11. Interface flange: PN4.0 DN25 HG20593 (side mounted)