Phone
13790503672
-
Address
No.1 Yimin Road, Mintian Industrial Zone, Shatian Town, Dongguan City, Guangdong Province
Dongguan Saice Testing Equipment Co., Ltd
13790503672
No.1 Yimin Road, Mintian Industrial Zone, Shatian Town, Dongguan City, Guangdong Province
|
1. Programmable (double-layer)High and low temperature test chambermainfunction |
|||
|
This series of products is suitable for testing various performance indicators of aerospace products, information electronic instruments and meters, materials, electricians, vehicles, metals, electronic products, and various electronic components in high and low temperature or humid and hot environments And for quality management purposes. |
|||
|
2Programmable (double-layer) high and low temperature test chamberspecifications |
|||
|
1. Product model |
SC-A-150D |
||
|
2. Internal volume |
150L |
||
|
3. Studio size |
50×60×50cm (W×H×D) |
||
|
4. External dimensions |
Approximately 118 × 169 × 126cm (W × H × D) |
||
|
5. Power supply |
380V±10%,50Hz±0.5HZ; |
||
|
6. Total power |
Approximately 15.5KW; |
Single constant power: about 4.5KW; |
|
|
7. Operating current |
Approximately 28 years old; |
|
|
|
8. Total weight |
About 850kg; |
||
|
9. Noise |
Measure at a distance of 1 meter from the machine and 1.2 meters from the ground in front of the machine, with a value of ≤ 75db; |
||
|
3Main technical parameters |
|||
|
1. Environmental conditions for use |
The ambient temperature is 5-30 ℃ and the relative humidity is ≤ 85% R.H; |
||
|
2. Functional requirements |
Indoor space cooling, heating, and heating; |
||
|
3. Temperature range |
-40~+150℃ |
||
|
4. Cooling rate |
+25℃→-40℃ 1℃/min |
Heating and cooling rate: average throughout the entire process; |
|
|
5. Heating rate |
+25℃→+150℃ 3℃/min |
|
|
|
6. Temperature resolution |
0.01℃; |
||
|
7. Temperature deviation |
≤2.0℃; |
||
|
8. Temperature uniformity |
≤2℃; |
||
|
9. Temperature fluctuation |
±0.5℃; |
||
|
10. Meet the testing standards |
GB31241-2014 Safety requirements for lithium-ion batteries and battery packs for portable electronic products |
||
|
notes |
The heat capacity of steel shall not exceed 35kg/m3 per cubic meter of load, and there shall be no active heat load during the wet heat test; |
||
|
|
The above performance indicators were measured under the conditions of an ambient temperature of+25 ℃ and a relative humidity of ≤ 85% R.H without a sample; |
||