Qualification/Frequency Conversion Anti Interference Dielectric Loss Tester

NegotiableUpdate on 12/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The qualification/frequency conversion anti-interference dielectric loss tester is suitable for measuring the TG δ and capacitance of high-voltage electrical equipment in workshops, laboratories, and research institutions; The loss testing of insulating oil has the advantages of convenience, simplicity, and accuracy.
Product Details

Qualification/Frequency Conversion Anti Interference Dielectric Loss Tester

Technical Specifications:

High voltage output: 0.5-10kV, with an increase of 500V for each level, there are ten levels in total, capacity: 1000VA
Accuracy: tg δ: ± (reading * 1.0%+0.08%)
Cx: ± (reading * 1.5%+5PF)
Resolution: tg δ: 0.01% Cx: 1pF
3PF< Cx < 60000PF
At 10KV, Cx≤30000PF
At 5KV, Cx≤60000PF
Power harmonic adaptability: ≤ 3%
Usage conditions: -15 ℃ -50 ℃ Relative humidity<80%

Technical Specifications

Product Model

ETCR9720A

ETCR9720B

CVT self-excited method measurement

none

have

input power

180V~270VAC, 50Hz/60Hz ± 1%, powered by mains or generator

Range of capacitance

Capacity range: 3~60kPF; Resolution: 0.001pF

Internal high voltage: 3pF~60000pF/10kV; 60pF~1.2μF/0.5kV

External high voltage: 3pF~1.5 μ F/10kV; 60pF~30μF/0.5kV

Dielectric loss accuracy

Cx: ± (reading x 1%+1pF); TG δ: ± (reading x 1%+0.00040)

Product Features

(1) It has positive/reverse wiring, internal/external standard capacitors, multiple working modes of internal/external high voltage, integrated structure, and can perform various conventional dielectric loss tests without the need for any external auxiliary equipment.

(2) LCD display, menu operation, rich test data, automatic discrimination of capacitive, inductive, and resistive samples, with a built-in micro printer for printing output.

(3) It has an external standard capacitor interface, which can be connected to an oil cup for precision insulation oil dielectric loss testing, an external solid material measuring electrode for precision insulation material dielectric loss testing, and an external high-voltage standard capacitor for high-voltage dielectric loss testing.

(4) Automatically identify 50Hz 60Hz system power supply and support generator power supply, even if the frequency fluctuates greatly, it can still be measured normally.

(5) Built in series and parallel dielectric loss measurement models for easy instrument calibration.

(6) Can store 255 sets of measurement data.

(7) When using the CVT self-excited method for measurement, C1/C2 can be measured simultaneously with one wiring, automatically compensating for the effects of bus grounding and standard capacitor voltage division, without the need for wire replacement or external accessories.

(8) Chinese graphic menu, large backlit LCD display for clearer clarity, real-time monitoring of current and voltage.

(9) Optimized circuit design ensures accuracy and stability of forward/reverse wiring.

(10) Automatically identify the frequency of the external high-voltage test power supply between 40Hz and 70Hz, supporting high-capacity and high-voltage dielectric loss tests for power frequency power supplies, variable frequency power supplies, and series resonant power supplies.

(11) Equipped with reverse wiring low-voltage shielding function, C11 can perform 10kV reverse wiring dielectric loss measurement without disconnecting the wire when the 220kV CVT bus is grounded.