The reactor fiber optic temperature measurement system adopts a fluorescent fiber optic temperature measurement device. The sensing probe of the device is made of imported quartz fiber, which has complete electrical insulation and is not affected by high voltage and strong electromagnetic fields. It is resistant to chemical corrosion and pollution, and has fast response speed, simple installation, high temperature resistance, and real-time online monitoring by backend software.
When the reactor sends abnormal or faulty signals, the faulty area of the reactor heats up and the temperature rises. By monitoring the temperature, the operating status of the reactor can be determined, thereby achieving the purpose of protecting the reactor. General temperature measurement devices are unable to measure the internal temperature of reactors. To solve this problem, our company's developed fluorescent fiber optic temperature measurement system can solve it through its anti-interference and high temperature and high voltage resistance characteristics.
The following parameters are displayed as standard parameters and can be customized according to specific customer needs, making it easier to respond promptly to inquiries by phone:
| ambient temperature | -20℃~+55℃ |
| ambient humidity | ≤95% (25℃) |
| Working Voltage | AC220V(+10%,-15%) |
| operating frequency | 50Hz or 60Hz (± 2Hz) (AC) |
| measurement range | -40 ℃~200.0 ℃ (customizable) |
| measurement accuracy | ±1℃ (可定制更高精度) |
| resolution | 0.1℃ |
| Control error | ≤±0.5℃ |
| Control output capacity | 5A/AC250V |
| Number of temperature measurement channels | 4 channels (expandable) |
| sensor type | Quartz fiber optic, standard 5-meter |
| Temperature compensation range | -19.9℃~+19.9℃ |
Note: This sensor is wirelessly calibrated and does not require manual calibration by the user. The system adopts adaptive measurement and does not require LD value calibration.
Our company has practical application cases of high-voltage reactor monitoring systems that can be directly put into use. Consultation Hotline
| Working power supply (customizable) | Temperature measuring element | Number of temperature measurement channels | Installation method |
|
1、DC110V
2、DC220V 3、AC220V |
Fluorescent optical fiber | 1-16 channels, multi-channel temperature measurement |
1. Embedded installation
2. Wall mounted installation |
| Basic functions (regular D-type) | 定制功能(特殊需求可定制) | ||
|
1. Three way winding temperature measurement; Automatic/manual start stop cooling fan; Compensation function for temperature display values in each channel
2. Provide black box function, which can record the temperature data of the last power outage and the highest historical temperature; 3. Digital tube display; 4. Provide transformer door cabinet point opening alarm function; 5. Provide 1 set of over temperature alarm contacts (1 normally open, 1 normally closed); 6. Provide 1 set of over temperature trip contacts (1 normally open, 1 normally closed); 7. Provide one set of remote transmission contacts for the fan (1 normally open, 1 normally closed); 8. Provide 1 set of temperature controller fault alarm contacts (1 normally open, 1 normally closed); |
1. Provide 1 way of iron core temperature measurement and 2 ways of iron core over temperature alarm contacts (1 normally open, 1 normally closed) (I function);
2. Provide RS485 communication function, communication with time stamps, capable of receiving time synchronization, MODBUS-RTU protocol (F function); 3. Fan fault diagnosis function, and provide fan fault alarm contact (L function); 4. Provide 4 independent 4-20mA analog current output functions (E function); 5. Provide temperature measurement and control for the computer room environment; (G function) 5. Alarm function for winding temperature rise rate and iron core temperature rise rate; 6. The communication protocol can adopt methods such as Profibus, IEC60870-5-103, Ethernet communication, etc; |
||