Rozhnik HC2A-S3 standard meteorological probe
Application:
HVAC, food, building equipment, paper, textile, pharmaceutical and other industries
Features:
Accuracy: ± 0.8% RH, ± 0.1 K, a at 23 ° C ± 5 K
• Measurement range: -50... 100 ° C/0... 100% RH
• Digital interface (UART) and analog signal output, 0... 1 V
Standard output range: 0... 1 V=-40... 60 ° C/0... 100% RH
Calibration at 23 ° C and 10,35,80% RH
Rozhnik HC2A-S3 standard meteorological probeTechnical Specifications:
| Precision, high-precision mode | ± 0.5% RH/± 0.1 ° C, at 10... 30 ° C At 23 ° C and 10, 20, 30, 40, 50, 60, 70, 80, 90% RH |
|---|---|
| Precision, standard precision mode | ± 0.8% RH/± 0.1 ° C, at 10... 30 ° C Calibration point at 23 ° C and 10, 35, 80% RH |
| Probe type | Meteorological probe |
| scope of work | -50…100 °C / 0…100 %rh |
| Power supply/power consumption | 3.3...5 VDC, Calibration @ 3.3 VDC / ~4.5 mA |
| long-term stability | <1% RH/year |
| sensor | Hygromer HT-1 |
| temperature sensor | PT100 1/3 DIN Class B |
| Probe protection | Polycarbonate plastic cover, white |
| filter element | Polyethylene filter, white, 40 μ m |
| Filter type | Polyethylene, 40 μ m |
| Response time T 63 | <15 sec. |
| High wind speed | 20 m/s, With filter |
| computational load | Dew point or frost point |
| Repeatability of AIRCHIP | 0.02 %rh / 0.01 °C |
| develop software | ROTRONIC HW4 |
| Adjust the probe through software | 1 point&multiple points% rh&° C |
| SOFTWARE UPDATE | Through the Internet and HW4 software |
| User information | From HW4 (Device Management) |
| Data processing through HW4 | Interface cable |
| The device is password protected | yes |
| User defined analog output | have |
| Analog output signal (standard) | 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C |
| communication interface | UART |
| Digital output signal (standard) | UART |
| Output signal type | 2 x 0…1 VDC |
| Shell material | polycarbonate |
| cable length | Passive cables can be up to 5m long, while active cables can be up to 100m long |
| Reverse voltage protection | Mechanical connection |
| Service interface | UART |
| FDA/GAMP compatibility | Compatible with FDA 21 CFR Part 11 and GAMP |
| size | Ø15 x 108 mm |
| weight | 17 g |