SYK-2801C Needle Penetration Tester
This instrument is designed and manufactured in accordance with the technical requirements and relevant regulations of GB/T 4509-1998/2010 "Determination of Penetration of Petroleum Asphalt", GB/T269 "Determination of Cone Penetration of Lubricating Greases and Stone Greases" and JTG E20-2011 "Test Code for Asphalt and Asphalt Mixtures in Highway Engineering" in the People's Republic of China's transportation industry standard T0604-2011 "Asphalt Penetration Test". It is mainly suitable for testing the penetration of asphalt and the cone penetration of lubricating grease (or stone grease). This instrument can also be used for the inspection of solid particles, powders, colloids, frozen bodies and other materials, as well as food raw materials such as cheese, sugar gum, butter, malt extract, cream, fermented bodies, etc. It can be widely used in the food industry, transportation and highway engineering, and other industrial sectors.
1、 Main technical features
1. Using a digital display to show the penetration value, it is intuitive and eye-catching.
2. The needle insertion timing control device has a total of 6 levels, with high timing accuracy.
3. It has the functions of coarse and fine adjustment of the lifting frame, easy adjustment, and accurate needle alignment.
4. Equipped with a tamper, a constant temperature bath, and automatic temperature control for the water bath, this machine is versatile and cost-effective.
5. Choosing different configurations such as standard needles, sample dishes, thermometers, and weights can be suitable for measuring according to the T0604-2011 standard in national standards GB/T 4509-1998, GB/T 4509-2010, and JTG E20-2011 (see Section 4, Instrument Accessories Configuration Table).
The biggest feature of this instrument is its advanced mechanical design and convenient lifting and adjustment; Digital temperature control meter, accurate temperature control; A high-precision digital testing table for needle penetration, with reliable measurement results.
2、 Main technical parameters and indicators
1. Measurement range: (0-600) needle penetration;
2. Needle insertion time control device: can select 5 seconds, 8 seconds, 10 seconds, 12 seconds, 30 seconds, and 60 seconds respectively, with a time error of less than ± 0.1 seconds;
3. Resolution of 0.01mm;
4. Needle insertion accuracy: ± 1 needle insertion degree;
5. Standard needle: 50mm, 2.5g ± 0.05g (basic configuration, see Section 4, Instrument Accessories Configuration Table for details);
6. Heater power: 200W;
7. Temperature control accuracy: (25 ± 0.1) ℃ (note: the ambient temperature should not exceed 20 ℃);
8. Temperature control method: high-precision digital temperature controller;
9. Thermostatic bath: for hard glass tanks;
10. Stirring: Magnetic stirring beads automatically stir;
11. Standard cone: (102.5 ± 0.05) g, in compliance with the specifications of the national standard GB/T269;
12. Lifting bracket: dual lifting and adjusting mechanism for coarse and fine adjustment, facilitating the alignment of the needle tip with the sample plane;
13. Working power supply: AC (220 ± 10%) V, 50Hz, power consumption not exceeding 300W.
14. Dimensions: 280mm x 350mm x 700mm (length x width x height).
15. Other: Equipped with a cold light source and magnifying glass for easy use and operation.
3、 Select accessories
Other cones: 1/2 cone, 1/4 cone.
4、 Instrument accessory configuration table
Our company's SYK-2801 series penetration tester is designed and manufactured according to the technical requirements and relevant regulations of the Chinese standard GB/T 4509-1998/2010 "Determination of Penetration of Petroleum Asphalt" and the Chinese transportation industry standard JTG E20-2011 "Test Code for Asphalt and Asphalt Mixtures in Highway Engineering" T0604-2011 "Penetration Test of Asphalt". By selecting different standard needles, sample dishes, thermometers, and weights, different standard viscosity tests can be achieved.
When selecting a needle penetration tester, users should choose different configurations based on Table 1 or specify which standard to use for testing to choose the corresponding needle penetration tester.
project |
GB/T4509-1998 Standard |
GB/T4509-2010 Standard |
T0604-2011 standard |
||
Needle |
50㎜,2.5g±0.05g |
3 pieces |
3 pieces |
3 pieces |
|
60mm, 2.5g ± 0.05g. |
—— |
3 pieces |
—— |
||
Dish |
Φ55㎜×H16㎜ |
—— |
3 pieces |
—— |
|
Φ55㎜×H35㎜ |
1 piece |
3 pieces |
3 pieces |
||
Φ55㎜×H70㎜ |
Optional |
3 pieces |
Optional |
||
Φ70㎜×H45 |
Optional |
Optional |
Optional |
||
Calculate |
(0-50) ℃, division 0.1 ℃ |
1 unit |
—— |
1 unit |
|
(-8~32) ℃, division 0.1 ℃ |
—— |
1 unit |
—— |
||
(25-55) ℃, division 0.1 ℃ |
—— |
1 unit |
—— |
||
Code |
50g |
1 piece |
1 piece |
1 piece |
|
100g |
—— |
1 piece |
—— |
||
1、 List of Supporting Instruments for SYK-2801C Needle Penetration Tester (Factory Standard)
Serial number |
Name |
Unit |
Quantity |
Remarks |
1 |
Needle penetration instrument body |
Taiwan |
1 |
|
2 |
Tamper |
Taiwan |
1 |
|
3 |
Bimetallic thermometer and bracket |
Item |
1 |
|
4 |
Standard needle (50mm, 2.5g ± 0.05g) |
Support |
3 |
|
5 |
Weight (50g) |
Block |
2 |
|
6 |
Sample dish (Φ 55mm × H35mm) |
Only |
1 |
|
7 |
Mercury thermometer (0-50) ℃, division 0.1 ℃ |
Support |
1 |
|
8 |
Cone penetration sampler |
Only |
1 |
|
9 |
○ Ring (Ø 105 × 5) |
Only |
1 |
Installed in the large sample container |
10 |
Standard cone |
A |
1 |
|
11 |
Needle connecting rod |
Deputy |
1 |
|
12 |
Glass sink |
Only |
1 |
|
13 |
Fuse 2A (Ø 5 × 20) |
Only |
2 |
|
14 |
Triangle bracket |
Only |
1 |
|
15 |
Magnetic stirrer |
Only |
1 |
|
16 |
Button battery LR44, 1.5V, with a diameter of 11.5 and a thickness of 5 |
Grain |
1 |
Display battery |
17 |
User Manual |
Share |
1 |
|
18 |
Product Qualification Certificate |
Share |
1 |
|
19 |
Product Warranty Card |
Share |
1 |
Note: According to the basic configuration of GB/T 4509-1998 standard, other configurations shall be purchased separately according to the requirements of the user at the time of ordering, as shown in Table 1 of the instruction manual.
2、 Reagents and equipment required for installation of SYK-2801C needle penetration tester
Serial number |
Name |
Specifications and requirements |
Quantity |
Remarks |
1 |
Propylene glycol |
500ml |
1 bottle |
|
2 |
Asphalt solvent (kerosene) |
1L |
1L/barrel |
Preparation is required for conducting asphalt experiments. |
3 |
Talc powder |
500 grams |
||
4 |
Scraper blade |
1 piece |
||
5 |
Brush brush |
50px wide |
2 pieces |
|
6 |
Electric furnace |
1000W |
1 piece |
Preparation is required for conducting asphalt experiments. |
explain:
1. The reagents and equipment required for instrument installation shall be provided by the user.
2. Please follow the relevant regulations for the use, handling, and storage of toxic and harmful reagents.
3. Before using this instrument, carefully read the user manual and industry standards.