Phone
13816688312
-
Address
No. 2229-6 Jinzhan Road, Tinglin Town, Jinshan District, Shanghai
Shanghai Pudie Valve Co., Ltd
13816688312
No. 2229-6 Jinzhan Road, Tinglin Town, Jinshan District, Shanghai
|
Electric regulating ball valve-Shanghai Pudie Valve Co., Ltd 1.Electric regulating ball valvesummary: This series of valves is a rotary ball valve with a core seat made of metal or metal to PTFE sealing. It combines the optimal control characteristics of ball valves and butterfly valves into one, and can be used as both a control regulating valve and a shut-off valve. 2.Electric regulating ball valveFeatures: (1) A one-piece valve body without any pipe joints, therefore not affected by pipeline or bolt stress, and because the valve body has no pipe joints, the pressure resistant shell will not be affected by pressure "sudden changes"; (2) Equipped with a V-shaped valve body, it can ensure precise control over the entire range even in low flow or high viscosity media; (3) The leak proof and durable valve seat is lined with a PTFE cup or O-ring with a stainless steel inner core at its outer diameter. The valve seat is made of tungsten cobalt hard alloy with a larger cross-section, and the structure of the valve seat is further reinforced by an alloy corrugated spring; (4) When the valve is closed, a wedge-shaped shear effect is generated between the V-shaped notch and the valve seat, which has both self-cleaning function and can prevent the ball core from getting stuck. It is particularly suitable for pipeline scaling and freezing, or for situations containing fiber and particle solids. Suitable for high viscosity, suspension, pulp and other unclean, fiber containing media. The direct connection method is used to connect with the actuator, which has the advantages of compact structure, small size, light weight, low resistance, stable and reliable action. The actuator is configured with electronic electric actuators such as UNIC, PSQ, HQ, DHL, or pneumatic piston actuators such as GTX and AL according to user requirements.
3.Electric regulating ball valveTechnical Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Basic error
|
backlash
|
dead zone
|
input signal
|
output signal
|
|
Full itinerary
≤±2% |
Full itinerary
≤±2% |
Full itinerary
≤0.8% |
4~20mADC
|
4~20mADC
|
|
Nominal diameter D (mm)
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
350
|
400
|
|
Rated flow coefficient Cv
|
32
|
43
|
78
|
90
|
160
|
250
|
360
|
610
|
1120
|
1850
|
2950
|
3700
|
7195
|
11466
|
|
Nominal pressure PN (MPa)
|
1.6, 2.5, 4.0, 6.4
|
|||||||||||||
|
flow characteristics
|
Approximate equal percentage (see typical curve chart), straight line characteristics
|
|||||||||||||
|
Valve plate angle (degrees)
|
0 ° to 90 ° (adjustable)
|
|||||||||||||
|
Allowable leakage level
|
Soft seal: zero leakage
Hard seal: ≤ rated Cv × 0.001% |
Soft seal: VI microbubble level, metal seal: ≤ rated CV × 0.065%
|
||||||||||||
|
Action time (S/90 degrees)
|
8.5~30
|
36~60
|
||||||||||||
|
Adjustable ratio
|
250:1
|
300:1
|
||||||||||||
5.Electric regulating ball valveFlow characteristic curve

|
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||