Based on an accuracy better than 0.074% (factory calibration accuracy of 0.05%)
·Range ratio 100:1
·Range: Differential pressure 100Pa~3Mpa, gauge pressure 1KPa~40Mpa
·Output signal: 4-20mA combined with HART protocol or PROFIBUS-PA protocol
·Overload limit: 42Mpa
·Static pressure influence:<0.15%/10Mpa
·Temperature range: ambient temperature -40~85 ℃ medium temperature -40~300 ℃
·Long term drift:<0.1%/5 years
·Temperature effect:<(0.08 · r+0.1)% (-10~60 ℃)
·Protection level: IP67
·Power supply: 10.5~45VDC
·MTBF: 435 years
HART communication makes operation easy
You can use the HART communication protocol and adjust all parameters using a PC or laptop, handheld communicator, or any HART compatible process control system. This means that the measured values and transmitter parameters are transparent at any point in the signal circuit. Using process equipment management software (PDM) based on well-known Windows operations can save a lot of time regardless of user experience.
PROFIBUS-PA full digital communication users can use PROFIBUS-PA and Profile 3.0 to conduct digital communication even in dangerous areas. The PROFIBUS-PA device can control three measurement tasks: flow rate (in m3/h, etc.), liquid level (in cm, etc.), and pressure (in bar, etc.). An additional electronic current limiter can prevent bus interruption in the event of a fault (fault current>3Ma).
It can also establish connections between PDS and various FCS process control systems. In this case, the Process Equipment Manager (PDM) software can serve as a medium to facilitate easy installation and operation.
Widely used, this transmitter has intrinsic safety and explosion-proof functions, and can be used in explosive hazardous areas (Zone 1). The product has passed China NEPSI certification, and its measuring unit and electronic components have CE testing certification, meeting the European Community CENELEC standards. Remote transmitters of different design types can be used for special applications, such as measuring high viscosity, high temperature and other media. The overload test standard for differential pressure transmitters is 63MPa, and the pressure transmitter is 6 times its range. Due to its high mechanical integrity, measuring elements with a rated overload of 42MPa can withstand a pressure of 100MPa, in other words, they will not actually be damaged at all.
Materials suitable for various applications
Even when measuring extremely corrosive substances, you can find a suitable solution in the PDS smart transmitter. For transmitters that are subjected to extremely corrosive media, the isolation diaphragm is made of stainless steel, Hastelloy, tantalum, Monel alloy, titanium, or gold. Special stainless steel can also be selected for the container, and the strength of PDS will be "indestructible".
The same PDS intelligent transmitter with certified quality can cope with various pressures, temperatures, explosions, and corrosive substances. In China, PDS is certified by the Instrumentation Explosion proof Safety Supervision and Inspection Station (NEPSI). The measurement unit and electronic components of PDS smart transmitters have obtained 44 certificates and certifications worldwide, including CENELEC, FM, CSA, HCF, and PROFIBUS-PAInternational.
Technical parameters of PDS403 pressure transmitter
measurement range |
1KPa~40MPa |
turndown ratio |
100:1 |
power supply |
10.5V~45V. d.c (intrinsic safety barrier power supply < 30V. D.C) |
output |
4mA~20mA d.c. and HART communication PROFIBUS-PA communication |
ambient temperature |
-40℃~85℃ |
medium temperature |
-40 ℃~100 ℃ (filled with silicone oil) |
precision |
≤(0.0029r+0.071)% |
temperature drift |
≤(0.08r+0.1)%(-10℃~60℃)
≤(0.1r+0.15)%/10℃ (-40℃~-10℃ 60~85℃)
|
Long term drift |
≤ 0.15r%/5 years |
Shell protection level |
IP67 |
Explosion-proof rating |
Ex ia II CT6 or Ex d II CT6 |
anticorrosion |
Select the appropriate material for the measuring part based on different media |
PDS403 Pressure Transmitter Selection Table
Model number |
Specification code |
Explanation |
PDS403 |
|
Pressure transmitter |
|
communication
agreement
|
H |
HART通信 |
P |
PROFIBUS-PA communication |
|
Capsule sealing liquid
|
|
Cleaning of sealed liquid measurement unit |
1 |
Conventional silicone oil |
2 |
Silicone oil degreasing and cleaning treatment |
3 |
Fluorooil degreasing and cleaning treatment |
|
measure
quantity
Quantity
Cheng
|
|
Range measurement range overload limit |
B |
1~100KPa -100~100KPa 600KPa |
C |
4~400KPa -100~400KPa 1MPa |
D |
0.016~1.6MPa -0.1~1.6MPa 3.2MPa |
E |
0.063~6.3MPa -0.1~6.3MPa 10MPa |
F |
1.16-16MPa -0.1~16MPa 25MPa |
G |
0.4~40MPa -0.1~40MPa 60MPa |
|
Material of the liquid receiving part
|
|
Isolation membrane related liquid receiving components |
S |
SUS316L SUS316 stainless steel |
H |
Hastelloy C-276 SUS316 stainless steel |
C |
Ha's C-276 Ha's C-276 |
|
process connection
|
0 |
G1/2 external thread pipe joint |
1 |
1/2-14NPT internal thread |
2 |
Equipped with elliptical flange (installation via hole Φ 12mm, not suitable for range G option) |
|
explosion-proof
|
A |
No explosion-proof |
B |
Intrinsic safety Ex ia II CT6 |
D |
隔爆 Ex d II CT6 |
electrical interface |
1 |
1/2-14NPT internal thread, two wiring ports |
2 |
M20 × 1.5 internal thread, two wiring ports |
Display header |
N |
Without display header |
D |
LCD display header |
|
mounting bracket
|
A |
Carbon steel installation bracket |
B |
Stainless steel installation bracket |
N |
No installation bracket |
Additional options |
/xx |
Refer to the additional selection table |