E-mail
ousimupower@163.com
-
Phone
18112608910
-
Address
No. 199, Tong'an Zhenshan Road, Suzhou High tech Zone
Suzhou Ousimu Electrical Equipment Co., Ltd
ousimupower@163.com
18112608910
No. 199, Tong'an Zhenshan Road, Suzhou High tech Zone
Product Introduction:
Single phase power inverter is a backup uninterruptible power supply. It mainly completes the inversion from DC to AC. Mainly designed and manufactured based on the characteristics and requirements of the power system, suitable for the high-quality and high reliability requirements of power supply equipment in the power system. The main circuit is assembled with advanced IGBT modules to improve the performance and reliability of the product. The output voltage adopts the design concept of power frequency isolation transformer, which enhances the impact resistance of the power supply and adapts to the requirements of different loads.
This series of inverter power supplies is designed specifically for substations and power plants, used for power remote control, communication, monitoring, emergency lighting, etc. It can also provide uninterrupted power for AC lubrication pumps, AC fans, and water pumps in power plants. This product can usually be set as DC main or AC main according to the application scenario, and switched by a static switch control.
Performance characteristics:
Using Intel microprocessors from the United States and original Mitsubishi IGBT from Japan
Adopting highly integrated digital circuit design to improve machine efficiency and effectively reduce failure rates
Pure sine wave output, with pure and stable waveform
The output adopts an isolation transformer, which ensures stable and safe output voltage
※ Full bridge circuit structure, suitable for any load
※ It is allowed to automatically switch to the mains bypass after cutting off the DC power in the startup state, without affecting the power supply of the load, making it convenient for maintenance and replacement of the DC power supply system
※ It has the characteristics of increasing losses, strong overload capacity, complete protection functions, modular packaging, etc., ensuring the stability and reliability of the inverter process
※ Equipped with output short-circuit protection; Super strong lightning protection, surge and surge protection; Overcurrent protection; Input overvoltage and undervoltage protection; Internal overheating protection
Product schematic:

Technical parameters of single-phase inverter power supply:
|
model |
OSM220 -11010 |
OSM220-11030 |
OSM220-11050 |
OSM220-11100 |
OSM220-11150 |
OSM220-11200 |
OSM220-11300 |
OSM220-11600 |
||
|
DC input |
rated voltage |
220V(Different voltages can be customized) |
||||||||
|
voltage range |
180-300V(Different ranges can be customized) |
|||||||||
|
rated current |
5A |
15.2A |
25A |
50A |
75A |
99A |
148A |
273A |
||
|
Bypass input |
Allowable voltage |
220Vac±15% |
||||||||
|
rated current |
4.5A |
13.6A |
22.7A |
45.5A |
67.5A |
91A |
136A |
250A |
||
|
switch time |
bypass ↔ inversion |
≤4ms |
||||||||
|
communication output |
Rated capacity |
1KVA |
3KVA |
5KVA |
10KVA |
15KVA |
20KVA |
30KVA |
60KVA |
|
|
rated power |
0.8KW |
2.4KW |
4KW |
8KW |
12KW |
16KW |
24KW |
48KW |
||
|
rated voltage |
220Vac |
380Vac(three-phase four-wire) |
||||||||
|
rated frequency |
50HZ |
|||||||||
|
rated current |
4.5A |
13.6A |
22.7A |
45.5A |
67.5A |
91A |
136A |
273A |
||
|
voltage accuracy |
220V±3% |
380V±3% |
||||||||
|
frequency accuracyHz |
50Hz±0.05Hz |
|||||||||
|
Waveform distortion degree(THD) |
≤2% (Linear load) |
|||||||||
|
Three phase load imbalance capability |
———————— |
≤100% |
||||||||
|
Dynamic response load0-100% |
5% |
|||||||||
|
Power factor(PF) |
0.8 |
|||||||||
|
overload capacity |
150%,10second |
|||||||||
|
Peak coefficient(CF) |
3:1 |
|||||||||
|
Inverter efficiency |
92% |
|||||||||
|
working environment |
Voltage resistance requirements |
2000Vac,1minute |
||||||||
|
Noise(1Rice) |
≤50db |
|||||||||
|
Temperature environment for use |
-10℃~+50℃ |
|||||||||
|
humidity |
0~90%No condensation |
|||||||||
|
Using altitudem |
≤2000m |
|||||||||
|
protection function |
Input reverse connection, undervoltage protection, output overload, short circuit protection, overheating protection |
|||||||||