Welcome Customer !

Membership

Help

Shandong Haihui Environmental Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Shandong Haihui Environmental Technology Co., Ltd

  • E-mail

    marketing@hve-china.com

  • Phone

  • Address

    Building B9, North High tech Industrial Corridor, Dongwu Road and Fenhe Road, Dongying City, Shandong Province

Contact Now

Six channel VOCs gas automatic sampling system

NegotiableUpdate on 11/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

VOCs Automatic Sampling System/Introduction Full Heat Tracing Six Channel Organic Volatile VOCs Gas Automatic Sampling System is based on the gas path principle of six channel valves, which can achieve full heat collection of up to six channels of sample gas. For some sites that require monitoring multiple sampling points, it can save costs and achieve multi-channel online continuous sampling without cross contamination

Product Details

VOCs automatic sampling system/Introduction

The fully heated six channel organic volatile gas automatic sampling system is based on the gas path principle of six channel valves, which can achieve full heat collection of up to six channels of sample gas. For some sites that require monitoring multiple sampling points, it can save costs and achieve multi-channel online continuous sampling without cross contamination.

VOCs automatic sampling system/feature

  • 6-channel VOCs batch measurement

    The VOCs sampling system can achieve up to 6 channels for VOCs batch measurement, with monitoring data automatically updated and saved separately to the database;

  • Six channel total heating method

    The automatic sampling system adopts a six channel total heat method to avoid the adsorption of VOCs on the pipe wall and valve body as much as possible, and the components are not lost;

  • Separate piping

    Separate piping is used between channels, and the common air pipe is very short and located in the heating zone to avoid cross contamination between channels as much as possible;

  • 6 heat tracing tube temperature controller

    The organic volatile gas collection system has integrated up to 6 heat tracing tube temperature controllers for easy on-site installation;

  • Automatic collection system

    The automatic collection system for organic volatile gas can be used in conjunction with a VOCs analyzer to calculate the equipment removal rate;

  • VICI six way valve

    The VOCs automatic sampling system adopts imported VICI six way valves, which have good performance and long service life;

Six channel VOCs gas automatic sampling system/parameter

project Project Parameters
heating temperature 0-220 ℃ (customizable)
Monitoring channel Up to 6 channels can be configured
Valve body specifications 316L SUS 1/16 connector
Air inlet and transmission pipeline specifications 316L SUS 6mm card sleeve connector
maximum power 5kW
power supply 220VAC±10% 50Hz
Overall Dimensions 525*350*215mm

VOCs automatic sampling system/Application field

1. Assist enterprises in reducing pollution discharge fees, which are directly related to equipment removal rates. Effective VOCs removal rate data can reduce pollution discharge fees; 2. Assist enterprises in process control, environmental protection and energy conservation, debug equipment based on export and import data, reduce energy consumption and meet emission standards; 3. Assist in handling equipment engineering company acceptance and calculate equipment performance, such as zeolite wheel concentration ratio, zeolite wheel removal rate, and back-end processing equipment removal rate.