The fully heated six channel organic volatile gas automatic sampling system is based on the gas path principle of six channel valves, which can achieve full heat collection of up to six channels of sample gas. For some sites that require monitoring multiple sampling points, it can save costs and achieve multi-channel online continuous sampling without cross contamination.
6-channel VOCs batch measurement
The VOCs sampling system can achieve up to 6 channels for VOCs batch measurement, with monitoring data automatically updated and saved separately to the database;
Six channel total heating method
The automatic sampling system adopts a six channel total heat method to avoid the adsorption of VOCs on the pipe wall and valve body as much as possible, and the components are not lost;
Separate piping
Separate piping is used between channels, and the common air pipe is very short and located in the heating zone to avoid cross contamination between channels as much as possible;
6 heat tracing tube temperature controller
The organic volatile gas collection system has integrated up to 6 heat tracing tube temperature controllers for easy on-site installation;
Automatic collection system
The automatic collection system for organic volatile gas can be used in conjunction with a VOCs analyzer to calculate the equipment removal rate;
VICI six way valve
The VOCs automatic sampling system adopts imported VICI six way valves, which have good performance and long service life;
| project | Project Parameters |
| heating temperature | 0-220 ℃ (customizable) |
| Monitoring channel | Up to 6 channels can be configured |
| Valve body specifications | 316L SUS 1/16 connector |
| Air inlet and transmission pipeline specifications | 316L SUS 6mm card sleeve connector |
| maximum power | 5kW |
| power supply | 220VAC±10% 50Hz |
| Overall Dimensions | 525*350*215mm |
1. Assist enterprises in reducing pollution discharge fees, which are directly related to equipment removal rates. Effective VOCs removal rate data can reduce pollution discharge fees; 2. Assist enterprises in process control, environmental protection and energy conservation, debug equipment based on export and import data, reduce energy consumption and meet emission standards; 3. Assist in handling equipment engineering company acceptance and calculate equipment performance, such as zeolite wheel concentration ratio, zeolite wheel removal rate, and back-end processing equipment removal rate.