1、 Overview narrate, recount, state
YK-33The intelligent coulomb meter is an intelligent instrument for measuring and controlling direct current electricity. It is used to accumulate and monitor the coulomb number of direct current electricity, timely grasp the consumption of the main components of the solution and the thickness of the coating, and automatically control the metering pump according to the set coulomb cycle to achieve the replenishment of solution components. This device uses a microprocessor for sampling calculation, which has the characteristics of high accuracy, stable performance, and easy operation. Widely applicable to industries such as electroplating, electrolysis, batteries, printed circuit boards, etc. The scientific management of production is of great significance.
2By measuring the Coulombic quantity and time, grasp the thickness of the electroplated coating;
3Master the consumption of main salts and additives in the solution, and control the operation of the metering pump according to the set cycle to achieve the addition of solution components;
4Accurately control the output of electrolysis in production;
5Measure the amount of charge and discharge during battery charging and discharging.
III Main functions
1Display function: Real time current valueA/J1Accumulated cycle and preset ampere hourT/CCycle batch number and preset ampere hourP/C,Total cumulative numberT(上下共8Position display);
2Alarm function: cycle cumulative alarm;
3Output function: Output relay delay signal according to the set cycle;
4Power off storage: Maintain original data during power outage;
5Communication interface: can be equipped with isolationRS232/485Output interface.
6Transmission output: isolated4~20mA、0~10/20mAOutput (load resistance)≤250Ω), the output range corresponds to the input range.
4、 Main technical indicators:
Basic error:0.2%FS±1a character
Input signal: Diverter signal0-75mVThe0-100mV,DC0~500V,DC0~1A
lose Output: Relay output contact capacityAC220V/3A
electricity Source: Switching power supplyAC85V~260V or DC12V DC24V
merit Consumption:4W
Ambient temperature0~50℃
ambient humidity:<85%RH
ruler Inch: 96×48×110mm
open Hole: 92×44mm
5、 Panel Description
The instrument panel has a dual row four position display,
When in working state: A/J1- current displayed on the upper row, no displayed on the lower row. (Relay action also lights up)
T/C - The upper row displays the cumulative cycle, while the lower row displays the preset ampere hour.
P/C - The upper row displays the batch number of cycles, and the lower row displays the preset ampere hour.
TOTAL - total cumulative value, displayed in 8 digits up and down.
Display screen image

Four button functions:
■—When setting the statePress this key to exit the settings state. In working condition,Switch to display batch parameter values.
En- Used to store the new set values of parameters and enter the next set parameter when setting the state
▲ - Used to increase the set value when setting the state.
▼When in the set state, it is used to reduce the set value. When in the working state, press and hold this key to clear the cycle cumulative value of the instrument.
6、 Parameter setting operation
hold downEnPress and hold the key until the prompt is displayed on the instrument panel-Cd-, bottom row display800Using ▲ and▼Key to password800Set as808,press againEnThe key only enters the parameter setting state, and entering other values is invalid to prevent non-technical personnel from accidentally modifying the parameters.
The parameter settings are as follows:
(1)inP- Signal from input current splitter(0-100mV),0-50,0-60,0-75,0-100mVOptional.
(2)Idot- Input current display accuracy setting, range0~3If set as1The current value is accurate to the decimal point1Position.
(3)I-PH- Full range of current input, range0~9999The factory is500.0.
(4)I-oE- Current zero point correction, range-99.9~99.9, factory value oSEt=0.0
(5) I-FS- Full currentCorrection,Range 0.500~2.000, corrected display value=FSEt × (measured value before correction+oSEt), factory value FSEt=1.000. In general, users can set zero point correction.
(6)Fun- Batch number (count) selection, set tooFF,Instrument to cycle cumulative automaticPUpper row+1, set ason,press▼ Manual operationPUpper row+1,TClear the upper row to zero.
(7) Hr- Ampere hour Ampere minute Coulombmeter selection setting,Set asHourFor hours, set min to minutes. Set SEC to seconds (Coulomb)
(8) . n- Cumulative measurement(Periodic alarm value, total cumulative value)Decimal point setting. Generally, it should not exceed the decimal place of the measured value. asdot=2, then.nThe parameters can be set to1In this way, batch alarms can be set within the range of999.9.
(9) P-HA- Periodic alarm value, when the periodic ampere hour reaches this value, the relayJ1Normally open and closed. scope0~9999.
(10) P-tS- Periodic alarm delay, unit: seconds. When the cumulative value of the cycle reachesP-HAWhen setting the value, the normally open point of the relay is closed, and after a set delay time, it automatically resets and the cumulative value of the cycle is reset to zero. When set as0At this time, the relay does not automatically reset. scope0~1000In seconds.
(11) Addr- Communication address and range of the instrument1~99.
(12) bAUd- Communication baud rate, range1200~9600.
7、 Reset working parameters to zero
The total ampere hour cumulative value and cycle ampere hour cumulative value of the ammeter can be reset to zero. In working condition,hold downEnPress and hold the key until the instrument panel displays a prompt-Cd-Using ▲ and▼Key to password800Set as798,press againEnkeyReset the cumulative value of the cycle, reset the relay, and exit the reset state.Set as796Press backEnReset the cumulative value of the key pair cycle and the total cumulative value, reset the relay, and exit the reset state. Instrument cycle reset terminal12、13Short circuiting can reset the cumulative value of cycle ampere hours to zero.
8、 Terminal wiring

9、 Communication instructions
This instrument can be equipped with RS232 and RS485 interfaces for direct communication with computers,RS485Standard Communicationdistance1.5kmMultiple instruments can be attached.RS232Standard Communicationdistance15mOnly one instrument can be attached.RS232Connect the TXD, RXD, and GND of the interface to the second, third, and fifth pins of the computer serial port, respectively. The data format consists of 1 starting bit, 8 data bits, and noneverify﹑1A stop position.To avoid communication conflicts, the instruments are all in listening mode. The computer sends a command to a certain instrument at a specified address, and then waits for a period of time for the instrument to respond. After the instrument receives the correct command, it sends out the data. After sending, the instrument is in listening mode again. In the same system, instrument addresses cannot be the same, and the baud rate must be *.
The instrument adopts the standard Modbus rtu communication protocol and supports function numbers 03 and 06. When using configuration software, the device to be selected is a Modicon PLC, Modbus RTU address type, with integer 16 bit data, starting from 4x001 or 4x000 using the Kingview register. Other configuration software may start from 3x001 or 3x000. The communication is an integer, and users need to handle the decimal places according to the actual situation.Communication transmission data is signed integer data, and it is recommended to define signed integer data for user programming. When the data is greater than0x8000When retrieving data, reverse adding is necessary1The actual value that is a negative number, for example, communication transmission data is0xFFFFThe corresponding data value is-1.For long integer data such asAccumulated quantity, etc., data value=high position×65536+Low position. During configuration, users can also choose the data type as long, and the system will automatically calculate the cumulative amount.
Read instrument data and send command format: It is recommended that the amount of data read at once should not exceed16a
address |
function number |
Starting address high bit |
Low order starting address |
Read the high bits of data |
Read low order of data quantity |
CRC16high position |
CRC16 low position |
01 |
03 |
00 |
00 |
00 |
03 |
05 |
CB |
On site measuring instruments return data format:
address |
function number |
byte count |
High numerical value |
numerical value low position |
High numerical value |
numerical value low position |
High numerical value |
numerical value low position |
CRC16high position |
CRC16 low position |
01 |
03 |
06 |
03 |
E8 |
03 |
E8 |
03 |
E8 |
C1 |
9F |
Write data to instrument and send command format: (Write to register)
address |
function number |
Starting address high bit |
Low order starting address |
Write high bits of data |
Low order of the number of data written |
CRC16high position |
CRC16 low position |
01 |
06 |
00 |
20 |
00 |
0C |
88 |
05 |
Data format returned by on-site measuring instruments: (same as the data format sent)
address |
function number |
Starting address high bit |
Low order starting address |
Write high bits of data |
Low order of the number of data written |
CRC16high position |
CRC16 low position |
01 |
06 |
00 |
20 |
00 |
0C |
88 |
05 |
Example: Read the first measurement value of the instrument with address 1 (PV1=1000)
Send data as 01 03 00 00 00 01 84 0A
The returned data is 01 03 02 03 E8 B8 FA (including 03 E8-1000)
(Among them, 01 is the instrument address, 03 is the function number, 00 00 is the register starting address, 00 01 represents reading a number, 840A is the checksum, and B8 FA in the returned data is the checksum. If you want to read the first and second data, you can send 01 03 00 00 02 C4 0B, and read 16 data and send 01 03 00 00 10 44 06.
The communication address range is 1-99, and the baud rate can be set to 2400 or 9600. The instrument has a default communication address of 248 (0XF8), which can be used for testing if the user is unsure. The baud rate is 2400 or 9600. After changing the communication address and baud rate, it needs to be powered on again to take effect.
The instrument has been set with a communication address of 1 and a baud rate of 9600 at the factory.
Register correspondence table (please refer to the setting section of the operating instructions for specific meanings)
4001 |
Current measurement value(4Position) |
4002 |
Total accumulated quantity high(4Position) |
4003 |
Low total cumulative quantity(4Position) |
4004 |
Batch cumulative high level(4Position) |
4005 |
Batch cumulative low level(4Position) |
Example: Read the PV (PV=1000) value of the instrument with address 1
Send data as 01 03 00 00 00 01 84 0A
The returned data is 01 03 02 03 E8 B8 FA (where 03 E8-1000), where 01 is the instrument address, 03 is the function number, 00 and 00 are the register start addresses, 00 and 01 represent reading a number, 84 and 0A are check codes, and B8 FA is the check code in the returned data. If you want to read two data, you can send 01 03 00 00 02 C4 0B.
10、 Precautions for use
1 All parameters need to be set before starting to use;
2 Power off operation should be performed when installing wiring;
3 Connect the millivolt analog signal with a shielded cable and rectifier ammeter, paying attention to positive and negative;
4 When the cumulative total safe time exceeds eight digits, it will automatically accumulate from zero;
5 Communication interfaces can be added according to user requirements;
6 If cumulative display is required by minute or second, please provide instructions when placing an order.