The online smoke monitoring system Gasboard-9050GHG, combined with multiple detection technologies such as infrared, electrochemical, ultrasonic, and ceramic zirconia, has strong resistance to gas cross interference. The system consists of four parts: a carbon emission continuous online monitoring system detection unit (CO2, CO, CH4, N2O), a flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), a data acquisition unit, and a processing unit. It is equipped with a high-temperature condensation extraction sampling device, and the probe and sampling pipeline are heat traced throughout the process. It can continuously monitor multiple indicators in flue gas online and dynamically.
Product Name:Smoke online monitoring system
Product model: Gasboard-9050GHG
Product Overview
Smoke online monitoring systemGasboard-9050GHG, combined with multiple detection technologies such as infrared, electrochemical, ultrasonic, and ceramic zirconia, has strong resistance to gas cross interference. The system consists of four parts: a carbon emission continuous online monitoring system detection unit (CO2, CO, CH4, N2O), a flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), a data acquisition unit, and a processing unit. It is equipped with a high-temperature condensation extraction sampling device, and the probe and sampling pipeline are heat traced throughout the process. It can continuously monitor multiple indicators in the flue gas online, and is suitable for monitoring the working conditions of various large-scale industrial fixed pollution source exhaust emissions.
Product Features
Obtained China Environmental Protection Product Certification (CCEP)
Easy maintenance: The probe uses a metal sintered filter to filter the sampling flue gas, with good filtering effect, high blowback efficiency, and long probe maintenance cycle
High measurement accuracy: Gas analysis uses proprietary non dispersive infrared (NDIR) gas sensor technology, which can accurately measure changes in CO2 gas concentration with an accuracy of up to 1% F.S
Long service life: All probes and sampling system components are made of corrosion-resistant materials and have automatic blowback function
Support remote monitoring and diagnosis: data can be transmitted to the higher-level centralized control system through multiple interfaces, providing real-time basis for remote monitoring and on-site process adjustment
Technical Specifications
| Measure components |
CH4、CO2、CO、N2O、O2
|
| Measuring principle |
CH4/CO2/CO/N2O: NDIR |
| O2: ECD |
| measurement range |
CH4/CO/N2O: 0~1000ppm |
| CO2/O2: 0~25% |
| precision |
CH4/CO2/CO/N2O: ≤±1%F.S. |
| O2: ≤±2%F.S. |
| resolution |
CH4/CO/N2O:1ppm |
| CO2/O2: 0.01% |
| response time |
T90<25s |
| repetitiveness |
≤±1% |
| Smoke temperature limit |
0~300°C |
| System compressed air requirements |
0.4~0.8MPa, No dust, no oil, no water |
| air consumption |
The maximum gas consumption is 2.2m3/h; Average gas consumption 0.45m3/h |
| airflow rate |
The maximum atmospheric flow rate is 2L/min; Average airflow rate of 1.5L/min |
| Heat tracing temperature (pipeline/probe) |
120~180°C |
| Protection level |
IP54 |
| Appearance dimensions (L * W * H) |
800mm*760mm*1800mm |
| ambient temperature |
-20~50°C |
| ambient humidity |
<95% RH (non condensing) |
| Electrical parameters |
| communication interface |
RS-485,RS-232 , 4~20mA,Ethernet |
| power supply |
220V AC±10%,>3000W |
| Function Configuration |
| Equipped with self diagnostic function, it can check the status of sensors online |
| Built in zeroing air pump, capable of achieving automatic air zeroing |