E-mail
jssc18@163.com
-
Phone
15261724159
-
Address
No. 8 Donglian Road, Dailou Industrial Concentration Zone, Jinhu County
Jiangsu Suchuan Instrument Co., Ltd
jssc18@163.com
15261724159
No. 8 Donglian Road, Dailou Industrial Concentration Zone, Jinhu County
Suchuan supplies intelligent high-precision power bar differential pressure flowmeter
The SC intelligent high-precision power bar differential pressure flowmeter is suitable for high-precision flow measurement of gases, liquids, and vapors. Weiliba is a differential pressure and rate averaging flow sensor that measures flow by measuring the differential pressure generated by the sensor in the fluid. The power bar reflects the true flow velocity of the fluid, with an accuracy of ± 1.0% and a repeatability of ± 0.1%.
performance metrics
Measurement accuracy: ± 1 Repeatability accuracy: ± 0.1
Applicable pressure: 0-40MPa Applicable temperature: -180 ℃~+550 ℃
Measurement upper limit: depends on probe strength Measurement lower limit: depends on the requirement for measuring small differential pressure
Range ratio: greater than 10:1
Applicable pipe diameter: 38mm~9000mm round pipe, square pipe
Applicable media: Full tube, unidirectional flow, unidirectional gas, steam, and liquid with viscosity not exceeding 10 centipoise
The application range of Veliba is extremely wide, and it is widely used in various gases, liquids, and vapors
Measurement of steam, the following are typical application media.
Characteristics of the Velbar Velocity Tube Flow Sensor
● Stable signal
The low-pressure tapping holes of the Weiliba are located on both sides behind the probe, between the separation point of the fluid and the probe, away from the vortex wave area.
Long term high precision
Weiliba can ensure long-term stability of accuracy because:
⑴. It is not affected by wear, dirt, and oil stains.
⑵. There are no movable parts in the structure.
⑶. The design eliminates the occurrence of blockage. At the front of the probe, a high static pressure zone surrounds the probe to prevent the high-pressure tapping hole from being blocked. It is important that the low-pressure holes are located on both sides of the probe side, and the fluid flows diagonally across the surface, protecting the low-pressure holes from being swept away. Other probes are prone to blockage because their low-pressure tapping holes are located in the low-pressure fluctuation area where impurities accumulate.
Low installation costs
⑴. Only a few inches of line welding is needed to complete the installation, which is very simple and fast.
⑵. Application tools can achieve online installation under pressure.
⑶. All valves and interfaces for various instruments only require simple assembly, which requires very low assembly costs.
Very low operating costs
⑴. It is a non constricting throttling design, and as an insertable flow probe, the operating cost of the Powerbar is low.
⑵. Velbar only produces very low * pressure loss, typically less than 0.7KPa
⑶. The * * pressure loss generated by an orifice plate component exceeds 14KPa
⑷. Compared to orifice plates, the energy loss of Powerbar has been reduced by 95%.
Suchuan supplies intelligent high-precision power bar differential pressure flowmeterTechnical parameters and applications
model |
SCW650 |
SCW640 |
SCW630 |
Outline drawing |
|
|
|
Diameter range |
80~500mm |
50~5000mm |
50~2000mm |
Applicable Medium |
Air, coal gas, flue gas, natural gas, tap water, boiler feedwater, and corrosive solutions; Saturated steam and superheated steam are equipped with condensers, etc |
Gas, liquid, steam |
|
pressure range |
Usually O~40.0MPa |
Usually 0~2.5MPa |
Usually 0~10.0MPa |
temperature range |
Usually -80~550 ℃ |
Usually -80~300 ℃ |
Usually -80~550 ℃ |
turndown ratio |
Greater than 10:1 |
Greater than 10:1 |
Greater than 10:1 |
Low flow velocity |
Gas ≥ 3.5m/s Liquid ≥ 0.6m/s Steam ≥ 9m/s |
Gas ≥ 3.5m/s Liquid ≥ 0.6m/s Steam ≥ 9m/s |
Gas ≥ 10m/s Liquid ≥ 1m/s Steam ≥ 12m/s |
measurement accuracy |
Shi 1 |
Shi 1 |
Shi 1 |
repetitiveness |
±0.1 |
±0.1 |
±0.1 |
connection method |
integral welding |
Online installation and adjustment |
Adjustable flange connection |
matching instrument |
Differential pressure transmitter, flow integrator, etc |
||
model |
SCW620 |
SCW610 |
SCW600 |
Outline drawing |
|
|
|
Diameter range |
50~4000mm |
50~5000mm |
12~50mm |
Applicable Medium |
Air, coal gas, flue gas, natural gas, tap water, boiler feedwater, and corrosive solutions; Saturated steam and superheated steam are equipped with condensers, etc |
Gas, liquid, steam |
|
pressure range |
Usually O~40.0MPa |
Usually 0-4MPa |
Usually 0~10.0MP a |
temperature range |
Usually -80~550 ℃ Special: 700 ℃ |
Usually -80~550 ℃ |
Usually -80~300 ℃ |
turndown ratio |
Greater than 10:1 |
Greater than 10:1 |
Greater than 10:1 |
Low flow velocity |
Gas ≥ 3.5m/s Liquid ≥ 0.6m/s Steam ≥ 9m/s |
Gas ≥ 3.5m/s Liquid ≥ 0.6m/s Steam ≥ 9m/s |
Gas ≥ 10m/s Liquid ≥ 1m/s Steam ≥ 12m/s |
measurement accuracy |
±1 |
±1 |
±1 |
repetitiveness |
±0.1 |
±0.1 |
±0.1 |
connection method |
integral welding |
Threaded rod connection |
Flange or threaded connection |
matching instrument |
Differential pressure transmitter, flow integrator, etc |
||