E-mail
36251363702qq.com
-
Phone
13838378516,15838302675
-
Address
No. 18 Tengfei Road, Guancheng District, Zhengzhou City
Zhengzhou Hangke Instrument Co., Ltd
36251363702qq.com
13838378516,15838302675
No. 18 Tengfei Road, Guancheng District, Zhengzhou City
1Introduction
Produced by Zhengzhou Hangke Instrument Co., LtdT210A series vibration sensorThe vibration acceleration sensor is composed of built-in acceleration sensitive components and main circuits such as amplification, filtering, and integration. It is powered by a+24VDC 4-10mA constant current source and outputs a bias voltage of about 11VDC. It can measure acceleration within 50g from 0.1HZ to 5kHz or velocity within 50mm/s from 5HZ to 5kHz. Acceleration sensors have the advantages of wide frequency range, large dynamic range, durability, strong reliability, good stability, easy installation, and strong anti-interference ability.
2、 Application scope
T210A series vibration sensorVibration acceleration sensors are widely used for monitoring the operating status of equipment in various industries. The vibration level during equipment operation is an important indicator for estimating whether the equipment is running normally. The acceleration sensor is used in conjunction with the vibration monitoring instrument produced by our company, and can output vibration acceleration, velocity, and displacement signal values.
3、 Technical indicators
Sensitivity: (20 ± 5 ℃) 100mV/g 3.94mV/mm/s. 3.98mV/mm/s. 4mV/mm/s optional and customizable
Measurement range (peak value): ± 50g
Large lateral sensitivity:<5%
Frequency range (± 10%): 1~9000Hz (± 3dB) 0.4~12000Hz
Amplitude linearity: ≤ 1%
Working temperature range: -40 to+120 ℃
temperature response
Impact (peak): 2000 g
Noise (rms):<30 μ V
Output impedance: < 100 Ω
Power supply (constant current source): 18-28 VDC
Working current: 2-10mA
DC bias voltage: 12 ± 2VDC
Base isolation: ≥ 108 Ω
Sensitive material: piezoelectric ceramic
Structural Design: Shear
Shell material: 304 stainless steel
Protection level: IP65
Weight: Approximately 100g
Installation instructions:
The installation base is connected to the tested point casing by M6 bolts, and an M6X1 installation hole with a depth of about 7mm is drilled at the tested point. The sensor can be tightened with the installation hole.
Wiring instructions:
On site, simply connect the two core shielded cables as required:
Terminal 1 (white wire+): connected to instrument IN
Terminal 2 (black wire -): connected to the instrument COM
Shielded wire: connected to instrument shielding
Attachment
Specification for Sensor Qualification Certificate Parameters
Install one bolt