Welcome Customer !

Membership

Help

Yancheng Tianyue Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

TYK-6H Air Microbial Sampler

NegotiableUpdate on 03/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
TYK-6H Air Microbial Sampler Brief Description: TYK-6H Impact Air Microbial Sampler is a dual function multi-stage impact sampler that can be widely used for monitoring air microorganisms in environments such as health and epidemic prevention, biological cleanliness, and pharmaceutical industry, as well as for sampling and research of air microorganisms in relevant research and teaching departments. It provides a basis for evaluating the hazards of air environmental microbial pollution and its prevention and control measures. TYK-6 Impact Air Microbial Sampler is a dual function multi-stage impact sampler that can be widely used for monitoring air microorganisms in environments such as disease prevention, health supervision, biological cleanliness, pharmaceutical industry, and related research and teaching departments. Product Model: Manufacturer Nature: Manufacturer Update Time: August 14, 2023 Visits: 759 Product Consultation Contact Us
Product Details

mainapplication

1. Environmental Air Research 2, Indoor Air Research

3. Hospital infection control 4. Microbial aerosol research 5. Sampling of bacteria and fungi, etc

Execution standard:

GBT 18204.3-2013 "Methods for hygiene inspection of public places (airborne microorganisms)"

Technical Specifications:
1Sampling principle:Level 6Impact method(Anderson's Principle)
2Sampling traffic:28.3L/min(Electronic constant current digital constant current constant voltage; Built in high-precision sensors; The instrument can be self calibrated, and the flow rate is not affected by voltage fluctuations and gas resistance changes)

3Flow error:≤±5%

4Traffic repeatability:≤2%

5Timing error:≤±0.1%

6. Load capacity: ≥ 15000pa

7. Timer mode: ① Loop sampling (extra large 99 cycles), can cycle volume or time sampling, set sampling time, pause time, and number of cycles.

② Manual sampling: After setting the sampling flow rate, you can directly sample, start timing, and manually shut down.

③ Timed sampling, set the sampling time, and stop sampling when the time is up.

④ Fixed volume sampling (extra large 1000L), set the sampling volume for sampling.

8. Noise: < 60dB

9measurement rangeCapture Rate>98%

10Collection device: using standard culture dishes(9cm)
11electricity sourceCan work after being fully charged6houraboveDual use of AC and DC.
12sampling timescope1-99 hours and 59 minutesAdjustable.
13Capture particle range6-stage sampler for particle size in sequenceLevel 1: ≥ 7 μ m, Level 24.7-7μm, Level 3: 3.3-4.7 μ m, Level 42.1-3.3μm Level 5: 1.1-2.1 μ m, Level 6: 0.65-1.1 μ m
14light 便 Type: Host weight3.6Kg