| Other functions: | Equipped with light column display, the range of light column display and digital tube display can be independently set separately. | Instrument wiring diagram: | Built in parameters of the instrument: |
|---|---|---|---|
| 0 | Parameter Code | symbol | name |
1 |
Instructions |
AL-1 | Alarm 1 setting |
2 |
The first alarm setting value, please refer to parameter ALP1 for the alarm method |
HY-1 | Alarm 1 time difference |
| 3 | Return difference setting for alarm contact output (single-sided return difference) | AL-2 | Alarm 2 setting |
| 4 | The second alarm setting value, please refer to parameter ALP2 for the alarm method | HY-2 | Alarm 2 times differential |
| 5 | Return difference setting for alarm contact output (single-sided return difference) | AL-3 | Alarm 3 setting |
| 6 | The third alarm setting value, please refer to parameter ALP3 for the alarm method | HY-3 | Alarm 3 times differential |
| 7 | Return difference setting for alarm contact output (single-sided return difference) | AL-4 | Alarm 4 setting |
| The fourth alarm setting value, please refer to parameter ALP4 for alarm mode | |||
| 8 | HY-4 | Alarm 4 times differential | Return difference setting for alarm contact output (single-sided return difference) submenu |
9 |
LOCK |
combination lock |
When LOCK=18, it is allowed to modify all parameters |
10 |
When LOCK ≠ 18, it is prohibited to modify all parameters |
SC |
Sensor error correction |
| 11 | When the measurement sensor causes errors, this value can be used to correct them | DP | decimal place When the instrument is used for voltage or current input, its display upper limit, display lower limit, decimal point position, and unit can be freely set by the manufacturer or user. When dp=0, the decimal point will not be displayed in units, and when dp=1-3, the decimal point will be displayed in tens, hundreds, and thousands, respectively. |
| 12 | P-SH | Display upper limit | |
| 13 | When the instrument is used for voltage and current input, the digital display shows the upper and lower limit set values (this menu is not displayed for inputs other than voltage and current) | The user can independently set the range of instrument digital display. | P-SL Display lower limit |
| 14 | G-SH | Light column display upper limit | |
15 |
The upper and lower limits of the instrument light column display determine the display range of the light column. |
The display range is determined by P-SH P-SL |
G-SL |
16 |
Light column display lower limit |
PF |
filter coefficient |
17 |
For the first-order lag filtering coefficient of the instrument, the larger its value, the stronger its resistance to instantaneous interference, but the response speed lags behind. Its value should be relatively small for pressure and flow control, and relatively large for temperature and liquid level control. |
ALP1 |
|
18 |
Definition of Alarm Method 1 |
'0' has no alarm; '1' upper limit alarm; '2' lower limit alarm |
|
| 19 | ALP2 | Definition of Alarm Method 2 | |
| 20 | ALP3 | Definition of Alarm Method 3 | ALP4 |
| 21 | Definition of Alarm Method 4 | ADDR | Mailing Address |