Two line ultrasonic level gaugeInstrument features
Instruments have the characteristics of safety, cleanliness, high precision, long service life, stability and reliability, and easy installation and maintenance. They are suitable for various fields such as acid, alkali, salt, corrosion prevention, and high temperature. It can be connected to display meters, PLCs, and various DCS systems through 4-20mA, providing real-time liquid level data for industrial automation operation. High quality power components are selected from the power supply section of the instrument circuit, and imported high stability and reliability components are chosen to replace similar imported instruments from abroad; The sound wave intelligent technology software can perform intelligent echo analysis without any debugging or other special steps. This technology has the functions of dynamic thinking and dynamic analysis, greatly improving the accuracy of the instrument. The liquid level accuracy reaches ± 0.25% and can resist various interference waves. Non contact instruments do not come into direct contact with liquids, resulting in a low failure rate. The instrument provides multiple installation methods, and users can calibrate the instrument through this manual. All input and output lines of the instrument have lightning protection and short-circuit protection functions.
Two line ultrasonic level gaugetechnical indicators
technical indicators |
parameter |
technical indicators |
parameter |
measurement range |
0-15m (customized according to the measured range) |
Blind spot |
0.35m~0.6m |
Distance measurement accuracy |
± 0.5% (standard conditions) |
Distance measurement resolution |
1mm |
Pressure |
atmospheric pressure |
instrument display |
Comes with LCD display |
analog output |
4~20mA |
power supply voltage |
DC24V |
ambient temperature |
-20℃ ~ +60℃ |
Protection level |
IP65 |
Installation method:
In open environments, bracket installation is generally used, and the instrument is fixed with its own screw ring. Or directly open a circular hole with a diameter of 60mm at the installation position on the top of the tank or lid, place the instrument in it, and then tighten the screw ring from bottom to top. Installation must ensure that the probe surface of the instrument is level with the measured liquid level. As shown in the figure on the right, the probe of the instrument reflects back to the probe after hitting the liquid level. After the probe receives it, the time from sending to receiving the wave is calculated to obtain the measurement distance H. The current liquid level L is obtained by subtracting the measurement distance H from the instrument installation height TH. The instrument range refers to the distance that the instrument can measure, and the installation height TH should be less than the range. The blind zone of the instrument refers to the area where the instrument cannot measure near the probe. The distance between the highest liquid level and the probe should be greater than the blind zone. For example, if the blind zone is 0.5m, the distance between the highest liquid level and the probe must be greater than 0.5m. For example, if the range is 6 meters and the blind zone is 0.45 meters, the actual measured highest liquid level is 0-5.55 meters. The wave emitted by the probe is a diffusion process, that is, there is a directional angle. Attention should be paid during installation, otherwise it may hit the protrusions on the pool wall or the edge of the channel.