Type of mass flow meter
Various specifications of instruments can directly obtain the mass flow rate, volume flow rate, density, and temperature of the measured liquid or slurry, without the need for manual calculation or estimation. It can exhibit excellent performance even in harsh working environments. It has no moving parts inside, does not require complex installation, and does not have strict requirements for working conditions. Each sensor is made of stainless steel material, and the multiple outputs of the transmitter can meet your various needs.
Type of mass flow meter
Technical Specifications
Product Name: Coriolis Mass Flow Meter
Caliber: DN1~DN100mm
Nominal pressure: 0.6-30MPa
Operating temperature: -40 ℃ to+200 ℃
Density range: 0.2 g/cm3 to 3.5 g/cm3
Accuracy: ± 0.2 to ± 0.5% FS
Range ratio: 1:10
Shell: Stainless steel
Power supply mode: external supply 24VDC
Output signal: 4-20mA two-wire system; Pulse 0-1000Hz; RS232/RS485; Hart Communication (or negotiated and provided according to user requirements)
Protection level: IP65; IP67; IP68
Explosion proof mark: intrinsic safety type ExiallCT4; Explosion proof ExdllCT4
Execution standard: Enterprise standard Q/BET05-06
Header display: Accumulated traffic; Instantaneous flow rate; Operating temperature; Operating pressure (only available with temperature pressure compensation); Rod shaped full-scale percentage; fault self-test
Connection method: double flange type, quick coupling type.
Directly measuring mass flow rate has high measurement accuracy.
It can measure a wide range of fluids, including various liquids with high viscosity, slurries containing solids, liquids containing trace gases, and medium to high pressure gases with sufficient density.
The vibration amplitude of the measuring tube is small, and it can be regarded as a non moving part. Measure the * and moving parts inside the pipeline.
Not sensitive to the distribution of upstream flow velocity, therefore there is no requirement for upstream and downstream straight pipe sections.
The measured value is not sensitive to fluid viscosity, and the influence of fluid density changes on the measured value is minimal.
It can be used for multi parameter measurement, such as measuring density at the same time, and deriving the concentration of solutes in the measurement solution from it.