The ultrasonic open channel flowmeter is used to measure the water level of the channel through non-contact measurement with an ultrasonic probe, and then the flow rate is calculated using the water level flow conversion method. Ultrasonic open channel flow meters must be paired with weir channels for measurement, usually using triangular weirs, rectangular weirs, and Bacher channels for measurement.
Ultrasonic open channel flowmeter for measuring the outflow of river water diversion
Ultrasonic open channel flow meters are used in conjunction with corresponding Bacher troughs, triangular weirs, rectangular weirs, and other weirs to measure the liquid level height using the propagation law of ultrasonic waves in the air. The liquid level information is continuously transmitted to the host, which automatically measures the instantaneous flow rate and cumulative flow rate through the computing system and stores them.
This instrument can complete flow detection without contact with fluids, and has complete liquid level measurement, control, data transmission, and human-machine communication functions. This machine is a flow measurement instrument that integrates ultrasonic transmission and reception sensors, servo circuits, temperature compensation sensors and compensation circuit units, integration host, display, control signal output, and serial data or analog output units. The measurement of fluid flow in many non full water, high flow (or low flow), naturally flowing free surface states is called open channel flow detection. Due to the large or small flow rate in open channels, there is often some corrosiveness or impurities carried in the fluid, making it difficult to detect the flow rate using a general pipeline flowmeter. For example, in the fields of industrial enterprise drainage, hospital wastewater, agricultural irrigation water, urban groundwater drainage, etc., open channel flow detection, especially non-contact ultrasonic open channel flow meters, are flow monitoring instruments.
Ultrasonic open channel flowmeter for measuring the outflow of river water diversion
Probe selection instructions:
Suggest using 100KHZ M48 * 2 probes for slots 1-5
Measuring range of 1 meter, it is not easy to hit the walls or corners of the Bacher trough and cause false signals
The blind spot of the probe is small, only 10-13cm, and the installation bracket can be made even lower
Suggest using a 64KHZ M48 * 2 probe for slots 6-25, with a measurement range of 2 meters and a blind spot of 30cm