VA500 Thermal Mass Flow Meter

NegotiableUpdate on 05/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The housing of VA500 thermal mass flowmeter adopts IP67 protection level, which is corrosion-resistant and can measure dirty gases with high impurity content. It has passed explosion-proof certification and can measure explosive gases. Basically, any mixed gas can be measured. In modern factories, instruments need to provide communication interfaces for the factory automation system. The VA500 thermal mass flowmeter not only supports traditional 4-20mA output and pulse output, but also supports various fieldbus interfaces. The instrument is designed modularly, so it is also very easy to use other field buses, and the VA500 can also support Bluetooth communication.
Product Details

VA 500 flow and consumption meter

VA 500 is a new preferred plug in flow meter for measuring compressed air and industrial gas flow in 1/2 "to 12" pipelines. Flow sensors are based on the principle of calorimetric measurement and do not require additional pressure and temperature measurements. The newly developed evaluation electronic device records all measurement values digitally. In the case of a large measurement range of 1:1000, this also leads to better accuracy.

The flow sensor has three measurement ranges - standard (92.7 m/s), * large. (185 meters/second) and high-speed (224 meters/second) versions. You can order devices with or without integrated displays. The version with a display screen shows real-time volumetric flow rate, speed, temperature, and total consumption. The diameter and consumption counter can be reset through the keyboard.



Product features
  • RS 485 接口 (Modbus-RTU)
  • Integrated display of m3/h and m3
  • Available from 1/2 "to 12" (DN 300)
  • Easy installation under pressure
  • 4 . .. 20 mA analog output, for m3/h orCubic meter per minute
  • Pulse output of m3
  • The inner diameter can be adjusted through the keyboard
  • Consumer counters can be reset
  • Adjustable through the buttons on the display screen: gas type, reference conditions, ° C and mbar, 4... 20 mA ratio, pulse weight
Touch button
  • Reset counter reading
  • Select measurement unit
  • Select OG gas type
  • Zero point adjustment, leakage flow suppression
4 displayed values
  • flow
  • eliminateFei
  • flow velocity
  • temperature
Value added indication
  • Real time, * small, * large, and average values
Easy setup through sensor keyboard
  • Flow unit selection
  • The diameter of the inner tube can be adjusted through the keyboard


Technical data
parameter In the case of compressed air, m3/h, l/min (1000mbar, 20 ℃).In the case of gas, Nm3/h, Nl/min (1013mbar, 0 ℃)
The unit can be adjusted through the buttons on the display screen m3 / h,m3 / min,l / min,l / s,ft / min,cfm,m / s,kg / h,kg / min
Adjustable through keyboard Counter can be reset
MEAS。principle Calorimetry measurement
sensor Thermal mass flow sensor
MEAS。medium Compressed air, gas
The gas type can be adjusted through the buttons on the display screen Compressed air, nitrogen, argon, nitrous oxide, carbon dioxide, oxygen, natural gas
MEAS。scope See the table below
Accuracy: ± 1.5% of measured value, ± 0.3% of full scale
L1 * level (mv: measured value) (fs: full scale) ± 1.0% of measured value ± 0.3% of full scale (as required)
Operating Temperature -30 . .. 110 ° C probe tube
-30 . .. 80 ° C shell
Operational pressure Up to 50 bar
digital output RS 458 接口, Modbus RTU
analog output 4 . .. 20 mA, m3/h are respectivelyLiters per minute;
Request: SCS
ling for cfm,m3 / min,l / min,l / s,ft /
min,m / s
pulse output 1 pulse per m3.Each electroplating separation
power supply 24 VDC
burden <500 ohms
housing Polyca bonate
Probe tube Stainless steel 1.4301, installation length 220 mm, Ø 10mm
install thread G 1/2“
Ø Housing 65 millimeters
Flow measurement range for compressed air VA 500
(ISO 1217:1000 mbar,20°C)
inner diameter of pipe standard
(92.7 m / s)
*Big.
(185.0 meters per second)
high-speed
(224.0 m / s)
inch millimeter DN m3/ h Cubic meter per hour Cubic meter per hour
1/2' 16.1 DN 15 2.5 . 760 liters per minute 3.5 . 1516 liters per minute 6.0 . 1836 liters per minute
3/4“ 21.7 DN 20 0.3 . .. 89 0.4 . .. 178 0.7 . .. . .. 215
1“ 27.3 DN 25 0.5 . .. 148 0.6 . .. . .. 295 1.1 . .. . .. 357
1 1/4“ 36 DN 32 0.9 . .. . .. 280 1.2 . .. . .. 531 2.5 . .. . .. 644
1 1/2“ 41.9 DN 40 1.2 . .. . .. 366 1.5 . .. . .. 732 3.0 . .. . .. 886
2“ 53.1 DN 50 2 . .. 600 2.5 . .. 1198 4.6 . .. 1450
2 1/2“ 71.1 DN 65 3.5 . .. 1096 5 . .. 2187 7 . .. 2648
3“ 84.9 DN 80 5 . .. 1570 7 . .. 3133 12 . .. 3794
4“ 110 DN 100 9 . .. 2645 12 . .. 5279 16 . .. 6391
5“ 133.7 DN 125 13 . .. 3912 18 . .. 7808 24 . .. 9453
6“ 159.3 DN 150 18 . .. 5560 25 . .. 11097 43 . .. 13436
8“ 200 DN 200 26 . .. 8786 33 . .. 17533 50 . .. 21230
10“ 250 DN 250 40 . .. 13744 52 . .. 27429 80 . .. 33211
12“ 300 DN 300 60 . .. 19815 80 . .. 39544 100 . .. 47881