VA550 flow sensor

NegotiableUpdate on 05/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The new VA550 flow sensor operates based on the principle of calorimeter measurement. Therefore, no additional temperature and pressure compensation is required. Due to its robust design, aluminum die cast casing, and sturdy sensor made of stainless steel 14571, the new VA550 flow sensor is suitable for harsh industrial applications and harsh environments. The ATEX version is suitable for applications in explosive areas. For flow measurement of natural gas, there are versions with DVWG inlet. Unlike the previously used bridge circuit, the newly developed evaluation electronic device records all measurement values digitally. This allows for very * * and fast measurements over a wide temperature range of up to 180 ° C (separated by 350 ° C). The measurement range is 1 ... 1000, VA550 has integrated Modbus output as standard, and all parameters such as Nm3/h, Nm3, Nm/s, Nl/min, Nl/s, kg/h, kg/min, ft/min, ° C, etc. can be transferred. All parameters can be adjusted directly on the instrument (through the display screen) or through handheld PI500 and current isolated pulse output for total consumption. Can be done through Modbus
Product Details

VA 550 flow and consumption meter

The new flow sensor VA550 operates based on the principle of calorimeter measurement.Therefore, no additional temperature and pressure compensation is required.Due to its robust design, aluminum die cast casing, and sturdy sensor made of stainless steel 14571, the new VA 550 is suitable for harsh industrial applications and harsh environments.The ATEX version is suitable for applications in explosive areas.For flow measurement of natural gas, there are versions with DVWG inlet.

Unlike the previously used bridge circuit, the newly developed evaluation electronic device records all measurement values digitally.This allows for very * * and fast measurements over a wide temperature range of up to 180 ° C (separated by 350 ° C).The measurement range is 1 1000, VA 550 has integrated Modbus output as standard, and all parameters such as Nm3/h, Nm3, Nm/s, Nl/min, Nl/s, kg/h, kg/min, ft/min, ° C, etc. can be transferred.All parameters can be adjusted directly on the instrument (through the display screen) or through handheld PI 500 and current isolated pulse output for total consumption.

Remote diagnosis can be performed through Modbus, and if necessary, all relevant parameters can be checked and changed.Therefore, it is possible to change the process conditions.Through remote diagnosis and status updates, such as temperature exceeding, sensor faults or calibration dates can be determined.



Product features
  • Display 4 values: Nm3/h, Nm3, Nm/s, ° C units can be freely adjusted
  • IP 67 sturdy and impact resistant aluminum die-casting shell, suitable for outdoor areas
  • Probe tube stainless steel 1.4571
  • Gas types (air, nitrogen, oxygen, argon, etc.) can be freely adjusted
  • Modbus interface as standard configuration, suitable for Profibus, Profinet, Modbus TCP, and HART
  • Pressure range up to 50 bar, special version up to 100 bar
  • Temperature range up to 180 ° C, optional temperature up to 350 ° C
  • Easy installation and disassembly under pressure through a 1/2 "ball valve
  • The shell can be twisted, displaying a 180 ° twist
  • Safety ring, used for installation and disassembly under pressure
  • Suitable for pipeline sizes from 3/4 "to DN 500
  • Option: ATEX certification ATEX II 2G Ex d IIC T4
  • Option: DVGW approves natural gas
4 displayed values
  • flow
  • consumption
  • flow velocity
  • temperature
Value added indication
  • Real time, * small, * large, and average values
Easy setup through sensor keyboard
  • Flow unit selection
  • The diameter of the inner tube can be adjusted through the keyboard


Technical data
measurement range 0.1 . .. 92,7 Nm / s, Standard version*
0.1 . .. 185 Nm / s,* 大Version*
0.1 . .. 224 Nm / s, High speed version*
*Measurement range Nm3/h suitable for different pipeline ranges
*All measured values are based on DIN 1343 standard conditions of 0 ° C and 1013 mbar at the factory
Accuracy: ± 1.5% mv ± 0.3% of fs
Accuracy level (mv: of meas. value) (fs: full-scale) ± 1.0% of mv ± 0.3% of fs (as required)
Repeatability: 0.25% mv during correct installation (installation assistance, position, entrance section)
Measuring principle Thermal mass flow sensor, measurement effect based on sensor PT 45 heated by bypass gas cooling.Measure the ambient temperature using PT 100. No additional pressure and temperature compensation is required.
response time t90 <3s
Working temperature range probe/display unit -40 . 180 ° C probe tube
0 350 ° C probe tube (high temperature version)
-40 . 70 ° C display unit
-40 . 120 ° C, suitable for ATEX version
Adjust through display screen, external handheld instrument PI 500, PC service software, remote diagnosis Nm3 / h,Nm3 / min,Nl / min,l / s,ft / min,cfm,kg / h,kg / min, Inner diameter, reference condition volume suppression, analog output calibration 4 .. 20 mA, Pulse/alarm, error code, etc
Gas type Compressed air, nitrogen (N2), argon (Ar), oxygen (O2), carbon dioxide (CO2), natural gas (NG), methane (CH4), hydrogen (H2), helium (H2), nitrous oxide (N2O), propane (C3H8), and biogas
output Modbus RTU, 2 x 4... 20 mA active/passive, weight can be freely selected), alarm * large48 VDC 0.5 A.
burden 500 ohms
Operational pressure Up to 50 bar
digital output RS 458 接口, Modbus RTU
analog output 4 . .. 20 mA, m3/h are respectivelyLiters per minute;
According to the requirement: SCS
ling for cfm,m3 / min,l / min,l / s,ft / min,m / s
pulse output 1 pulse per m3.Each electroplating separation
power supply 24 VDC
burden <500 ohms
3 internal counters 1 x total counter cannot be deleted, 1 x total counter can be deleted, and freely adjustable counters can be deleted between 1 minute and 1 day, such as 1/2 hour counter and daily counter
Additional average calculation All parameters can be freely adjusted from 1 minute to 1 day, such as the average value of 1/2 hour and the average daily value
protection level IP 67
material Aluminum die-casting shell
Probe tube stainless steel 1.4571
connect Can provide G 1/2 "ISO 228, NPT 1/2", R 1/2 ", PT 1/2"
Operational pressure 50 bar;Special version 100 bar (DVGW certified * up to 16 bar)
power supply 18 . .. 36 VDC,5 W
agree ATEX II 2G Ex d IIC T4,DVGW
Flow measurement range VA 500 standard version (92.7 m/s)
inner diameter of pipe Full scale value, in Nm3/h*
inch millimeter DN air N2 argon O2 CO2 methane
nature
GasCH4
1/2“ 16.1 DN 15 45 40 71 43 45 26
3/4“ 21.7 DN 20 89 79 139 85 88 52
1“ 27.3 DN 25 122 108 191 116 120 72
1 1/4“ 36 DN 32 218 194 342 208 216 129
1 1/2“ 41.9 DN 40 320 285 501 305 317 189
2“ 53.1 DN 50 530 471 829 506 525 313
2 1/2“ 71.1 DN 65 913 811 1426 870 902 539
3“ 84.9 DN 80 1390 1237 2176 1327 1377 823
4“ 110 DN 100 2183 1940 3412 2082 2159 1290
5“ 133.7 DN 125 3423 3039 5345 3261 3382 2021
6“ 159.3 DN 150 4941 4382 7706 4701 4877 2914
8“ 200 DN 200 8816 7809 13733 8378 8690 5193
10“ 250 DN 250 13742 12216 21483 13106 13595 8124
12“ 300 DN 300 19836 17613 30972 18895 19601 11713

*According to DIN 1343 Nm3/h: 0 ° C, the gas is 1013.25 hPa
**ISO 1217:20 ° C, air at 1000 hPa

Flow measurement range VA 500 Max.Version (185.0 m/s)
inner diameter of pipe Full scale value, in Nm3/h*
inch millimeter DN air N2 argon O2 CO2 methane
nature
GasCH4
1/2“ 16.1 DN 15 90 80 142 86 90 53
3/4“ 21.7 DN 20 177 158 278 169 176 105
1“ 27.3 DN 25 243 216 381 232 241 144
1 1/4“ 36 DN 32 436 388 682 416 432 258
1 1/2“ 41.9 DN 40 639 568 1000 610 633 378
2“ 53.1 DN 50 1059 941 1655 1010 1048 626
2 1/2“ 71.1 DN 65 1821 1619 2846 1736 1806 1076
3“ 84.9 DN 80 2778 2470 4343 2649 2750 1643
4“ 110 DN 100 4357 3874 6811 4154 4312 2576
5“ 133.7 DN 125 6824 6068 10668 6507 6754 4035
6“ 159.3 DN 150 9839 8748 15380 9381 9738 5818
8“ 200 DN 200 17533 15590 27409 16718 17353 10368
10“ 250 DN 250 27428 24389 42877 26153 27147 16220
12“ 300 DN 300 39544 35162 61817 37706 39138 23384

*According to DIN 1343 Nm3/h: 0 ° C, the gas is 1013.25 hPa
**ISO 1217:20 ° C, air at 1000 hPa

Flow measurement range VA 500 high-speed.Version (224.0 m/s)
inner diameter of pipe Full scale value, in Nm3/h*
inch millimeter DN air N2 argon O2 CO2 methane
nature
GasCH4
1/2“ 16.1 DN 15 110 98 172 105 109 65
3/4“ 21.7 DN 20 215 191 336 205 213 127
1“ 27.3 DN 25 295 262 461 281 292 174
1 1/4“ 36 DN 32 528 470 826 504 523 312
1 1/2“ 41.9 DN 40 774 689 1211 738 766 458
2“ 53.1 DN 50 1282 1140 2005 1223 1268 758
2 1/2“ 71.1 DN 65 2204 1960 3447 2102 2181 1304
3“ 84.9 DN 80 3364 2991 5259 3208 3328 1990
4“ 110 DN 100 5275 4691 8248 5030 5030 3120
5“ 133.7 DN 125 8263 7384 12918 7879 7879 4887
6“ 159.3 DN 150 11913 10594 18625 11360 11360 7046
8“ 200 DN 200 21229 18879 33190 20244 20244 12557
10“ 250 DN 250 33211 29534 51921 31669 31669 19644
12“ 300 DN 300 47880 42579 74856 45657 45657 28322

*According to DIN 1343 Nm3/h: 0 ° C, the gas is 1013.25 hPa
**ISO 1217:20 ° C, air at 1000 hPa