Welcome Customer !

Membership

Help

Beijing Yukotaiji Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Valve switch frequency recorder manufacturer

NegotiableUpdate on 12/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The manufacturer of the valve switch frequency recorder has multiple switch inputs and can record the closing and opening time of the switch according to the system time. Used to record the number and duration of device switches, and browse the recorded data through buttons. Each switch can record 30000 sets of data, including the time (year, month, day) and status of the switch action. The data recording adopts a first in first out cyclic recording method. The instrument is equipped with a built-in hardware clock, and power outages do not affect the operation of the clock.
Product Details

1Valve switch frequency recorder manufacturerOverview

YK214LCDThe series switch quantity recorder adopts advanced microcomputer chips and technology to measure, display, store and communicate on-site switch quantity signals and level signals. It can be used128*64Wide temperature LCD display or4rowLEDDigital tube display. (Please provide written instructions for using LCD display)

YK-214LCDThe series switch quantity instrument has multiple switch quantity inputs and can record the closing and opening time of the switch quantity according to the system time. Used to record the number and duration of device switches, and browse the recorded data through buttons. Each switch quantity can be recorded3Ten thousand sets of data, including the time (year, month, day) and status of switch actions, are recorded using a first in, first out cyclic recording method.The instrument is equipped with a built-in hardware clock, and power outages do not affect the operation of the clock.

YK-214LCDThe recorder can be made into a pulse signal or TTL level signal input recorder according to customer requirements. It can be connected to industrial equipment such as PLC and computer through RS232 or RS485 communication interface to form an industrial measurement and control system. The instrument is equipped with a rechargeable battery inside for clock operation. When the instrument is not in use for a long time, it is recommended to power it on for 24 hours every six months to charge the battery.

IIValve switch frequency recorder manufacturerMain technical indicators

1·Input signal: passive switch contact, pulse signal,TTLLevel, etc

2·Display mode: wide temperature blue screen with white text highlightedLCDdisplay.

3·Record data capacity: withUplate30000Article, withoutUplate 950Article.

4·Alarm output:The instrument can be equipped with up to 16 relay alarm outputs, 220V/3A. (Ordering Instructions)

5·Communication output: isolated communication interfaceRS485(Standard)Modbus-RTUCommunication Protocol

Baud rate1200~9600bps internal free setting

6·Working environment: Temperature050humidity<85RH

7·Electricity Source: Switching power supply 85265VACorDC24Vpower consumption<4W

8·External dimensions:160×80×120mm(Plate mounted horizontal) 80×160×120mm(Plate mounted vertical)320×120×270mm(Desktop)

It can be equipped with a serial communication interface and can communicate bidirectionally with various devices with serial interfaces to form a network control system. It has multiple standard external dimensions and can be applied to various measurement and control scenarios. The whole machine adopts a snap in structure, which is very easy to install.

Can be matchedUSBInterface, user useUExport data to diskUPlate, usingExcleThe table can be opened.

III Valve switch frequency recorder manufacturerModel Description

type score

say bright

YK-214

LCD

Intelligent switch quantity recorder

outside form

ruler inch

A

horizontal format160×80×125mmopening152×76

A/S

vertical form80×160×125mmopening76×152

T

desktop320×120×250mm

number of channels

□□

1-8road

alarm output

H

Unified upper limit alarm for each channel

L

Unified lower limit alarm for each channel

D

Each channel has independent alarms (Z multiple)8Road)

input signal

K

Switching quantity, contact signal (passive)

M

pulse signal

T

TTLlevel

communication output

P

mini printer

R

Serial communicationRS232

S

Serial communicationRS485

U

USBData export

power supply

220VACpower supply

W

DC24Vpower supply

This series of instruments has a fully English operating interface, please specify when ordering the English version.

4、 Operating instructions

IKey Description

- Press this key to select the parameters to view in the settings and browsing states.

En- Setting upplaceWhen in state, it is used to store the new set values of parameters and select the next set parameter.

- Used to increase the set value when setting the state. Or query the alarm status.

- Used to reduce the set value when setting the state. Or query the alarm status.

IIDisplay instructions

The instrument displays the system time and working status when it is in operation.

Instrument display working status screen:

IIIParameter settings

pressEnKey, display input password800Using ▲800Set as808You can enter to set parameters.

(1)Number of detection channels: You can set the number of channels to be detected. scope1~8

(2)Filter frequency, range130After detecting the switch action multiple times in a row, it is determined that there is a change in the input. When set as20When judging the time, it is approximately5In seconds.

(3)J1Output: SelectJ1Is the relay outputting? Select YesJ1Relay output, select 'No'. The relay does not output.

(4)Display mode: Instrument panel display mode, available (normal)/Alarm), (disconnect)/Close), (Run)/Stop), (Power on)/Shutdown is available for selection, press ▲ or▼ Select.

(5)Communication address: The communication address and range of the instrument199.

(6)Baud rate: the baud rate of communication, range1200~9600.

(7)Clock Year: Set the date of the year, for example11Yes, it is2011Year.

(8)Clock Date: Set the current month and day.

(9)Clock Time: Set the current time.

After the setting is completed, the instrument will exit the setting state and automatically enter the working state.

IVRecord browsing

pressEnKey, display input password800Using ▲800Set as818You can enter the storage data browsing mode.

Query record screen

VRecord clearance

Recorder data pressedEnKey, display input password800, usingturn800Set as798You can enter the record reset state.

5Terminal wiring

6、 Application of switch quantity recorder

The on-off recorder detects the start and stop of the equipment, checks the factory equipment, and records its usage. To ensure the troubleshooting and usage of factory instruments and equipment.

This product adopts surface packaging modular technology, greatly improving the anti-interference ability of the instrument. It has functions such as display, control, and communication, and is suitable for displaying and recording equipment usage. It can be widely used in fields such as electricity, metallurgy, chemical industry, petrochemicals, paper printing and dyeing, brewing, communication, tobacco, aerospace bases, etc.

7USBData export

Instruments can be equipped withUSBInterface, export data toUIn the plate.UDisk demandFATorFAT32Format, generate file as*.xlsThe table data file. Like generating file files0316-1.XLS, indicating3moon16Daily exported files, record data for * channels. When entering the password, enter the password800change to816After entering the data export interface, confirm and export the recorded data toUIn the plate.

In the figure, * rows represent the recorded data of * channels, with the number of records192Indicating that it has been recorded192Article. The second line indicates that03moon16day11:21:40The channel is closed. The third and fourth lines indicate that11:21:41to break off.

After opening the file, it will look like the following picture:

useUDisk storage, clear it firstUData files or formatting in the diskUPlate.

8Communication Instructions

This instrument can also have an RS485 interface for direct communication with a computer,RS485Standard Communicationdistance1.5kmMultiple instruments can be attached.The data format consists of 1 starting bit, 8 data bits, and noneverify1A stop position.

Using the standard Modbus RTU communication protocol, it can be connected to almost all configuration software, including Kingview, Power Control, Century Star, etc Fix、InTouchWaiting for domestic configuration software eliminates the hassle of users connecting to the softwareWhen using configuration software, the device to be selected is a PLC with Modicon (* Kang), Modbus RTU address type, integer 16 bit data, starting from 4001 using the Kingview register. Other configuration software may start from 3001.

4001

*Road input status

4007

system clock time

4002

Second input status

4008

*Road record data volume

4003

Third input status

4009

The second way records the amount of data

4004

Fourth input status

4010

The third way records the amount of data

4005

system clock year

4011

The fourth way records the amount of data

4006

system clock month day

4012

write1Clear record data

Example: Read the input status value of the instrument with address 1 (the status value is 1 when the input contact is closed and 0 when disconnected)

Send data as 01 03 00 00 00 01 84 0A

The returned data is 01 03 02 00 01 79 84 (where 00 01 represents a status value of 1 and the input 1 contact is closed), where 01 is the instrument address, 03 is the function number, 00 and 00 are the register start addresses, 00 and 01 represent reading a number, 84 and 0A are check codes, and 79 84 is the check code in the returned data. If you want to read data in two input states, * and 2, you can send 01 03 00 00 02 C4 0B.

The data recorded by the instrument can also be read through communication. When sending communication commands for the recorded data of channels one to four, the address Addr of the instrument should be set to 100-103 (0X64-0X67) to indicate that the corresponding channel's recorded data is being read. Determine how many sets of data there are based on the recorded data volume of each channel. It is recommended to read three sets of data each time, namely month, day, hour, year, and status value. Year and status are used as data, for example, 120 represents 2012 with a status of disconnected, and 131 represents 2013 with a status of closed. For example, send 64 03 00 00 03 0C 3E to read * channel's * set of recorded data, read the data, and then send 64 03 00 00 03 FC 3E to read the second set of data. If the data volume of the * group record is 5, the next read command after Z is 64 03 00 0C 00 03 CC 3D. When reading recorded data, the instrument does not perform functions such as input status monitoring and key browsing.

9、 Warranty

If it is a manufacturing quality problem caused by the factory, the instrument will be repaired free of charge from the date of leaving the factory. If the damage is caused by improper storage and use, the repair cost will be charged. The warranty period is twelve months, and the warranty period of 3-5 years must be specified separately.

Beijing Yukotaiji Electronics Co., Ltd