WNK59 Intelligent Pressure Transmitter

NegotiableUpdate on 12/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

WNK59 Intelligent Pressure Transmitter

Product Details

Absolute pressure and gauge pressure measurement of gases, vapors, or liquids in various process control fields;

• Measurement of liquid level, volume, or mass;

• Higher pressure can reach700bar

• Accuracy: for the span of the measurement range+0.075%

For range ratios greater than10:1The situation,

precision=Range span ±[0.025+0.005(URL/Range span]%.




model

Product Description

WNK59

Intelligent pressure transmitter

code

certification

A

Used for non explosion proof purposes

1

ExiaCT6

2

ExiaCT4

3

ExdBT6

For other certifications or certification information that is currently being applied for, please contact Wanke Company

code

code

A

4…20mA

H

4…20mAHART

P

PROFIBUS-PA

F

FF

code

display

A

No display

L

LCD

code

Shell, cable entry, protection level

A

aluminium14M20×1.5IP66/67

B

aluminium14G1/2IP66/67

C

aluminium141/2NPTIP66/67

code

Rated range of sensor gauge pressure

code

Rated range of sensor absolute pressure

1C

100mbar (10kPa/1mH2O)

2C

100mbar (10kPa/1mH2O)

1E

250mbar (25kPa/2.5mH2O)

2E

250mbar (25kPa/2.5mH2O)

1F

400mbar (40kPa/4mH2O)

2F

400mbar (40kPa/4mH2O)

1H

1bar (100kPa/10mH2O)

2H

1bar (100kPa/10mH2O)

1K

2bar (200kPa/20mH2O)

2K

2bar (200kPa/20mH2O)

1M

4bar (400kPa/40mH2O)

2M

4bar (400kPa/40mH2O)

1P

10bar (1MPa/100mH2O)

2P

10bar (1MPa/100mH2O)

1S

40bar (4MPa/400mH2O)

2S

40bar (4MPa/400mH2O)

1U

100bar (10MPa/1000mH2O)

2U

100bar (10MPa/1000mH2O)

1W

400bar (40MPa/4000mH2O)

2W

400bar (40MPa/4000mH2O)

1X

700bar (70MPa/7000mH2O)

2X

700bar (70MPa/7000mH2O)

code

Calibration, Unit

1

Calibrate the rated range,mbar/bar

2

Calibrate the rated range,kPa/MPa

3

Calibrate the rated range,mmH2O/mH2O

4

Calibrate the rated range,psi

code

Membrane material

1

316L

2

合金C-276

X

Other special requirements

For other special requirements for membrane, please contact Wanke Company

code

Process connection thread

GA

external threadG1/2, inner hole3mm316

GB

external threadG1/2, inner hole11.4mm316

GC

internal threadG1/2, inner hole3mm316

GD

internal threadG1/2, inner hole11.4mm316

NA

external thread1/2NPT, inner hole3mm316

NB

external thread1/2NPT, inner hole11.4mm316

NC

internal thread1/2NPT, inner hole3mm316

ND

internal thread1/2NPT, inner hole11.4mm316

MA

external threadM20×1.5, inner hole3mm316

MB

external threadM20×1.5, inner hole11.4mm316

JX

Other special requirements

For other special requirements for connecting threads, please contact Wanke Company

code

Material of process connectors

3

316

H

合金C

code

Overvoltage protection

A

none

M

Overvoltage protection

code

mounting bracket

A

none

U

Pipe installation bracket

Typical model:WNK59AHL A1P21 MA3 AU