E-mail
1172591273@qq.com
-
Phone
1806687891213347428711
-
Address
5th Floor, Tongda Building, No. 10 Keji Road, Xi'an City
Xi'an Xinmin Electronic Technology Co., Ltd
1172591273@qq.com
1806687891213347428711
5th Floor, Tongda Building, No. 10 Keji Road, Xi'an City
■ Connect resistance ruler and potentiometer.
■ single6bitLEDDisplay, the display range is-99999~99999
■ Optimized the input circuit based on the characteristics of the resistance ruler (potentiometer)
■ Improved display and measurement stability, enhanced ability to resist electromagnetic interference and series mode interference.
■ 0.05Grade accuracy, measurement and control speed per second5~200Secondary adjustable, display range-99999~99999.
■ Panel buttons and switch input setting function.
■ 10Point and line correction function.
■ Optional1~4Point alarm output. This includes six basic alarm modes: upper limit of measurement value, lower limit of measurement value, upper limit of deviation, lower limit of deviation, upper limit of absolute deviation, and lower limit of absolute deviation. It also includes four standby alarm modes: upper and lower limits of standby, and upper and lower limits of standby deviation.
(Standby alarm mode: Refers to the instrument not sounding an alarm even when it is in the alarm zone when powered on, and establishing a standby condition when the measured value enters the non alarm zone.),Afterwards, the alarm will sound normally.
Content |
Code Explanation |
||||||||||
XSAEW- |
0.05Level measurement accuracy; Single display; |
||||||||||
Overall dimensions |
AH |
160×80×125 Aperture size:152×76 |
|||||||||
CH |
96×48×82 Aperture size:92×45 |
||||||||||
Panel specifications |
6bitLED, display range-99999~99999 |
||||||||||
input signal |
W |
Potentiometer(0.5~100kΩ) |
|||||||||
Open (optional) |
K1 |
1Click to enter (AHTheCHchoiceK1At that time, communication and transmission can only choose one |
|||||||||
|
Alarm (optional) (250V AC/3A, resistive load) |
AH |
T1~T4 |
1~4Point relay output, all normally open+Normally closed dual contacts |
||||||||
CH |
T1~T2 |
1~2Point relay output, all normally open+Normally closed dual contacts |
|||||||||
T3 |
3Point relay output, with a single normally open contact |
||||||||||
|
Transmission (optional) (Optoelectronic isolation, resolution:1/3000Load capacity:600Ω) |
A1 |
Current output(4-20)mA、 (0-10)mA、 (0-20)mA |
|||||||||
A2 |
Voltage output(1-5)V、 (0-5)V |
||||||||||
A3 |
Voltage output(0-10)V |
||||||||||
Communication (optional)(Optoelectronic isolation, communication speed:2400、4800、9600、19200、38400、57600、115200)(Mailing address:0-99) |
MS1 |
RS232interface Can be selected through software settingsTCASCIIorModbus-RTU |
|||||||||
MS2 |
RS485interface Can be selected through software settingsTCASCIIorModbus-RTU |
||||||||||
Power Specifications |
V0 |
100~240V AC 50/60 Hz |
|||||||||
V1 |
10~24V AC 50/60 Hz;10~24V DC |
||||||||||