YD-812N fixed dichloromethane detection alarm

NegotiableUpdate on 10/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

YD-812N Fixed Dichloromethane Gas Detector with Display Product Overview Our company's intelligent gas detector uses natural diffusion to detect gas concentration, and adopts imported catalytic combustion sensors and infrared sensors with excellent sensitivity and repeatability

Product Details

YD-812N fixed dichloromethane gas detector with display
Product Overview
Our company's intelligent gas detector uses natural diffusion to detect gas concentration, and adopts imported catalytic combustion sensors and infrared sensors with excellent sensitivity and repeatability; LCD or LED digital displays suitable for factory applications display the concentration value of leaked gas in real time, and immediately activate a light alarm signal when it exceeds the preset alarm point; The international standard (4-20) mA signal can be directly connected to the factory DCS system; The instrument adopts embedded microcontroller technology, with simple operation, complete functions, high reliability, and overall performance leading in China.
Main functions
The instrument adopts advanced 16 bit ultra-low power embedded microcontroller
LCD display (two-wire detector) or LED digital display (three wire detector)
Users can set their own high and low alarm points
Automatic calibration function to reduce measurement errors
Important operations require password verification to effectively prevent accidental operations
The standard (4~20) mA signal can be directly connected to the factory DCS system
technical indicators
Measurement range: see attached table
Applicable gases: flammable gases, oxygen, toxic and harmful gases
Display error: ≤± 5% F.S
Response time: T90<30s
Display mode: LED digital tube display or LCD liquid crystal display
Alarm prompt: Ultra high brightness illuminated alarm indicator
Alarm point: Level 1 alarm can be set by the user
Level 2 alarm user can change settings
Signal output: Standard (4~20) mA signal
Working environment: -30 ℃ to+50 ℃; Humidity<90% RH, no condensation
Working voltage: DC10V~30V
Explosion proof grade: Exd Ⅱ CT6
Protection level: IP66
Installation thread: M20 × 1.5 G1/2
Using cables: 2 × 1.5mm2 or 3 × 1.5mm2 shielded cables
Transmission distance: ≤ 1000m
Weight: Approximately 1200g
name Tested gas measurement range resolution response time Sensor lifespan
Combustible gas detection detector Dichloromethane 0-100%LEL 1%LEL ≤ 30 seconds 3-5 years
Carbon monoxide detector CO 0-1000PPM 0.1PPM ≤ 30 seconds 2-3 years
Oxygen detector O2 0-25%VOL 0.1VOL ≤ 30 seconds 2-3 years
hydrogen sulfide detector H2S 0-100PPM 1ppm ≤ 30 seconds 2-3 years
Hydrogen detector H2 0-1000PPM 1ppm ≤ 30 seconds 2-3 years
Chlorine gas detector CL2 0-20PPM 0.1ppm ≤ 30 seconds 2-3 years
Ammonia gas detector NH3 0-100PPM 1ppm ≤ 30 seconds 2-3 years
Sulfur dioxide detector SO2 0-20PPM 0.1ppm ≤ 30 seconds 2-3 years
Nitric oxide detector NO 0-250PPm 1ppm ≤ 30 seconds 2-3 years
Nitrogen dioxide detector NO2 0-20PPm 0.1ppm ≤ 30 seconds 2-3 years
Hydrogen cyanide detector HCN 0-20PPm 0.1ppm ≤ 30 seconds 2-3 years
Ethylene oxide detector ETO 0-100ppm 1ppm ≤ 30 seconds 2-3 years
Hydrogen chloride detector HCL 0-20ppm 0.1ppm ≤ 30 seconds 2-3 years
Bromomethane CH3Br 0-100ppm 0.1ppm ≤ 30 seconds 2-3 years