YLN-SVR-24 radar flowmeter is a non-contact flow velocity measurement device that uses the Doppler effect principle to calculate the frequency difference between the electromagnetic waves emitted by the radar at a fixed frequency and the electromagnetic waves reflected back from the measured fluid surface. Through relevant calculations, the flow velocity on the fluid surface is obtained. It can perform non-contact measurement of fluid surface velocity in open channels, natural rivers, drainage networks, etc., which is easy to install and maintain, and easy to operate. Widely applicable in hydrology, flood control and drainage, environmental pollution monitoring and other fields, achieving 7x24 hour online monitoring.
|
serial number |
parameter |
scope |
Remarks |
|
1 |
operating frequency |
24GHz |
|
|
2 |
Speed measurement range |
0.1~20m/s |
Related to flow state |
|
3 |
speed measurement accuracy |
±0.01m/s;±1%FS |
|
|
4 |
Beam angle |
12° |
|
|
5 |
installation height |
0~35rice |
Related to the flow state, it is recommended to install at a height of<5rice |
|
6 |
vertical angle |
30~70° |
suggestion55~60°; recommended roll angle < ±2° |
|
7 |
Automatic vertical angle compensation |
Accuracy ±1°, resolution 0.1° |
|
|
8 |
power supply |
DC6~30V |
|
|
9 |
power consumption |
Working current: <60mA Standby current:<35mA(@DC12V) |
|
|
10 |
contact method |
RS485,MODBUSagreement |
Customizable protocol |
|
11 |
Baud rate |
9600~115200bps |
|
|
12 |
Operating Temperature |
-35~70℃ |
|
|
13 |
Temperature output |
Resolution:0.1℃, accuracy: ±1℃ |
|
|
14 |
Protection level |
IP67 |
|
|
15 |
weight |
0.45kg |
|
|
16 |
size |
105*105*60mm |
|