After mixing the water sample and regulator, nickel ions react with the indicator in an ammonia environment to form a colored complex. The analyzer detects the change in color and converts it into a nickel ion value for output. The amount of colored complex generated is equivalent to the amount of nickel ions.
Select valve components: Choose reagent sampling timing, flexible and diverse channels, versatile functions, and have the smallest dead volume,
Advantages such as easy maintenance and high lifespan.
It has printing function and can be connected to a printer (optional) to print the measured data in a timely manner.
adopt7The inch touch screen and simple operation interface can achieve easy learning, operation, and maintenance for users.
Extremely large data storage capacity, achieving no less than5Preservation of historical data for years (with measurement intervals of)1time/1h)It greatly meets the needs of customers.
Automatic liquid leakage alarm function, when a reagent leakage occurs, the instrument will automatically alarm and prompt the user to perform maintenance.
The use of optical signal recognition function ensures high accuracy in quantitative analysis.
Simplified and convenient maintenance of chemical reagents, with monthly replacement1The use of secondary reagents greatly reduces the maintenance workload for users.
UOne click upgrade of the disk makes software updates easier.
1 Method basis: spectrophotometric method.
2 Measurement range:0.01-15 mg/L
3 Accuracy: not exceeding ±10%Or not exceeding ±0.02mg/L.
4 Repeatability: not exceeding ±5%Or not exceeding ±0.02mg/L.
5 Measurement cycle: The minimum measurement cycle is20Minutes, according to the on-site environment, can be5~120minModify the color rendering time arbitrarily.
6 Sampling period: time interval(10~9999minArbitrary adjustable) and whole point measurement mode.
7 Calibration cycle:1~99The day can be adjusted at any interval and any time.
8 Maintenance cycle: usually once a month, approximately30 min.
9 Reagent consumption: less than0.50yuan/Sample.
10 output:2roadRS-232;1road4~20mA.
11 Environmental requirements: Temperature adjustable indoor environment, recommended temperature+5~28℃; Humidity ≤90%(No condensation).
12 Power Supply:AC220±10%V,50±10%Hz,5A.