YQ120TG-D65 Adjustable Illumination Standard Light Source Lightbox

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Description: YQ120TG-D65 adjustable illumination standard light source light box, equipped with four D65 light sources, D75 light sources, CWF light sources, UV light sources, TL84 light sources, U30 light sources, TL83 light sources. F or A light source, up to three types of light sources can be installed at the same time, and the light source can be selected by oneself. Philips D65 light source 1310 * 800 * 100mm. The illumination can be adjusted from high to low, and can be used for hanging installation or hanging installation. Color matching rooms generally use three to four units for accurate color matching, which are commonly used in the printing industry, as well as other industries such as decoration, automotive, textile, plastic, coatings, etc.
Product Details
Details

YQ120TG-D65 Adjustable Illumination Standard Light Source Lightbox

Equipped with four D65 light sources, D75 light sources, CWF light sources, UV light sources, TL84 light sources, U30 light sources, and TL83 light sources. F or A light source, up to three types of light sources can be installed at the same time, and the light source can be selected by oneself. Philips D65 light source 1310 * 800 * 100mm. The illumination can be adjusted from high to low, and can be used for hanging installation or hanging installation. Color matching rooms generally use three to four units for accurate color matching, which are commonly used in the printing industry, as well as other industries such as decoration, automotive, textile, plastic, coatings, etc.

YQ120TG-D65 Adjustable Illumination Standard Light Source Lightbox

Precautions for daily use and maintenance

1. Use of standard light source: After the light source tube is lit for 30 minutes, the color temperature, color rendering index, and illuminance reach their optimal state; Unless there are special reasons, frequent switching of the power supply should be avoided.

2. Service life of light source tubes; After 2000-3000 hours of use, the color temperature, color rendering index, and illuminance of standard light source lamps will decrease. It is recommended to replace them in a timely manner to avoid affecting the color matching effect.

3. Cleaning and maintenance; Before cleaning and maintenance, please unplug the power plug, cut off the power, use a regular cleaning agent to wipe the equipment, and then wipe it clean with a clean and soft cloth. Do not rinse directly with water.

YQ120TG-D65 Adjustable Illumination Standard Light Source LightboxWarranty Statement

The light source products sold by Chuanzhong Company are guaranteed for one year from the date of arrival at the customer's company. If there are any quality issues with the products within one year, the company will be responsible for repairing or replacing them.

Both products of Chuanzhong Company have standardized packaging. If users receive the goods and find any damage to the packaging or products inside, please contact Chuanzhong Company as soon as possible so that we can handle it for you

After 3 damaged light tubes, please replace them with professional standard light source tubes. Chuanzhong Company provides long-term supply of light tubes such as 36w1200, Philips 6500k or 5000k, etc

If you have any unclear installation or usage issues, please contact our technical engineers directly.

YQ120TG-D65 Adjustable Illumination Standard Light Source LightboxTheme packing list

ITEM NAME

quantity

lighting source

1 set

Light source hook

4 pieces

Wall top hook

4 pieces

power line

1root

Load chain

4 pieces

Installation and Use Manual

1 book

YQ120TG-D65 Adjustable Illumination Standard Light Source LightboxSpecial precautions

1Before use, it is necessary to check whether all voltages match the markings on the local voltage label.

2Before use, check whether the power cord and plug are damaged.

3Please do not twist or pull the power cord to avoid poor contact.

4Turn off the power before unplugging.

5Do not unplug the power plug with wet hands, as there is a risk of induction and electric shock.

YQ120TG-D65 Adjustable Illumination Standard Light Source LightboxSimple troubleshooting

Turn on the switch, the light source is not on

1Is the power cord properly plugged into the socket.

2The clamp of the lamp holder may be loose, tighten it.

3Check if the lamp tube is damaged or burnt out, replace the lamp tube.

The reflection on the board surface is dim

Wipe clean with a clean and soft cloth.

The light source timer does not count

Press the reset button to restart.

Installation sequence

  1. Determine the installation location based on the type of direct or oblique beam.
  2. Install ③ at the corresponding positions on the roof to ensure * fixation.
  3. Install ② separately into the rivet nuts on the back of ①.
  4. Confirm the hanging height, generally around 110cm (+/-10cm) from the observation table to the lamp tube.
  5. Confirm the length of the ④ steel wire rope according to the height, and make the collar.
  6. Suspension: Place one end of the steel wire rope on ② and the other end on ③ to ensure horizontal stability.
  7. Connect the power cord, turn on the switch, and use a standard light source.