Welcome Customer !

Membership

Help

Jiangsu Hengke Measurement and Control Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Jiangsu Hengke Measurement and Control Instrument Co., Ltd

  • E-mail

    1095143601@qq.com

  • Phone

    18936740760

  • Address

    No. 358 Shenhua Avenue, Jinhu County Industrial Park

Contact Now

Yokogawa EJA110A transmitter

NegotiableUpdate on 12/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
This model of equipment is commonly used in the EJA transmitter series and has a relatively high frequency of use in various industries. The EJA110A differential pressure transmitter is used to measure the liquid level, density, and pressure of liquids, gases, or vapors, and then convert them into a 4-20mADCTM current signal output. EJA110A can also communicate with BRAN controller, TMYHC4100, CENTUMCS, FieldMate, HART375 for setting and monitoring.
Product Details

Our company acts as an agent for the complete range of Yokogawa EJA transmitters, including EJA110A differential pressure transmitter, EJA430A pressure transmitter, EJA120A micro differential pressure transmitter, Yokogawa EJA130A high static pressure differential pressure transmitter, EJA310A pressure transmitter, EJA440A high static pressure transmitter, Yokogawa EJA210A/EJA220A flange transmitter, EJA510A/530A absolute pressure transmitter, EJA118 diaphragm sealed differential pressure transmitter, EJA438 diaphragm sealed pressure transmitter, and EJA115 micro flow transmitter.

Specification of EJA110A

EJA110A differential pressure transmitter

L membrane box

M membrane box

H membrane box

V-film box

measurement range

-10~10kPa
(-40~40inH2O)

100~100kPa
(-400~400inH2O)

500~500kPa
(-2000~2000inH2O)

-0.5~14MPa
(-70~2000psi)

Measurement range

0.5~10kPa
(2~40inH2O)

1~100kPa
(4~400inH2O)

5~500kPa
(20~2000inH2O)

0.14~14MPa
(20~2000psi)

precision

±0.075%

±0.065%

±0.065%

±0.065%

Protection level

IP67,NEMA 4X, And JIS C0920 immersion proof type

Explosion proof specifications

FM,CENELEC ATEX,CSA,IECEx

output signal

4~20mA DC, FOUNDATION fieldbus or PROFIBUS PA two-wire digital communication

power supply

BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC)
Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC)

ambient temperature

-40~85℃ (-40~185℉) (普通型)
-30~80 ℃ (-22~176 ℉) (with built-in indicator)

process temperature

-40~120℃ (-40~248℉) (普通型)

Great work pressure

16MPa(2300psi)
L membrane box (special material) 3.5MPa (500psi)

install

2-inch pipe installation

Material of liquid receiving components

bellows

SUS316L (diaphragm: Hastelloy C-276),
Hastelloy C-276, tantalum material, Monel

Container flange

SUS316, Hastelloy C-276, Monel

shell

Aluminum alloy or SUS316 stainless steel (optional)

Specification of EJA120A

EJA120A Micro Differential Pressure Transmitter

E-membrane box

measurement range

-1~1kPa(-4~4inH2O)

Measurement range

0.1~1kPa(0.4~4inH2O)

precision

±0.2%

Protection level

IP67,NEMA 4X, And JIS C0920 immersion proof type

Explosion proof specifications

FM,CENELEC ATEX,CSA,IECEx

output signal

4~20mA DC or FOUNDATION fieldbus or PROFIBUS PA two-wire digital communication

power supply

BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC)
Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC)

ambient temperature

-25~80℃(-13~176℉)

process temperature

-25~80℃(-13~176℉)

Great work pressure

50kPa (7.25psi)

install

2-inch pipe installation

Material of liquid receiving components

bellows

SUS316L (diaphragm: Hastelloy C-276)

Container flange

SUS316

shell

Aluminum alloy or SUS316 stainless steel (optional)

Specification of EJA430A

EJA430A pressure transmitter

A membrane box

B membrane box

measurement range

-0.1~3MPa
(-15~430psi)

-0.1~14MPa
(-15~2000psi)

Measurement range

0.03~3MPa
(4.3~430psi)

0.14~14MPa
(20~2000psi)

precision

±0.065%

±0.065%

Protection level

IP67,NEMA 4X, And JIS C0920 immersion proof type

Explosion proof specifications

FM,CENELEC ATEX,CSA,IECEx

output signal

4~20mA DC or FOUNDATION fieldbus or PROFIBUS PA two-wire digital communication

power supply

BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC)
Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC)

ambient temperature

-40~85℃ (-40~185℉) (普通型)
-30~80 ℃ (-22~176 ℉) (with built-in indicator)

process temperature

-40~120℃ (-40~248℉) (普通型)

High overvoltage

4.5MPa (645psig)

21MPa (3000psig)

install

2-inch pipe installation

Material of liquid receiving components

bellows

SUS316L (diaphragm: Hastelloy C-276),
Hastelloy C-276, tantalum material, Monel

Container flange

SUS316, Hastelloy C-276, Monel

shell

Aluminum alloy or SUS316 stainless steel (optional)