Phone
18968916605
-
Address
No. 20 Industrial Road, Dongfang Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province
Zhejiang Shige Fluid Technology Co., Ltd
18968916605
No. 20 Industrial Road, Dongfang Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province
Large caliber pneumatic three control valves ZJHQ, ZJHXpneumatic control valveAdopting a cylindrical thin-walled window shaped valve core guidance, different from the liner guidance of a plunger shaped valve core. Equipped with multiple spring actuators, it has the advantages of simple structure, light weight, small volume, and easy disassembly and assembly. Widely used for precise control of processes involving gases, liquids, and other media, such as maintaining pressure, flow rate, temperature, and liquid level at given values. Suitable for situations where a fluid is split into two streams through a three-way valve or two fluids are combined into one fluid through a three-way valve.
This series of products has two types: three-way merging and three-way branching. The nominal pressures are PN16, 40, and 64; The nominal diameter range is DN25-300. The applicable fluid temperature ranges from -60 ℃ to+450 ℃. The leakage standard is level IV. There are two types of flow characteristics: straight lines and parabolas.
Main component materials and recommended temperature range for use
|
Part name
|
material
|
temperature range
|
|
Valve body
Upper and lower valve covers |
HT200
|
-20~200℃
|
|
ZG230-450
|
-40~450℃
|
|
|
ZG1Cr18Ni9Ti
|
-250~550℃
|
|
|
Valve core, valve seat, valve stem
|
1Cr18Ni9
|
-250~550℃
|
|
seal pad
|
Rubber asbestos board
|
|
|
Stainless steel winding pad
|
|
|
|
filler
|
PTFE
|
|
|
Upper and lower membrane covers
|
A3steel plate
|
|
|
diaphragm
|
35CrMoA
|
|
|
35 A3
|
|
|
|
Bracket, top plate
|
HT200
|
|
|
compression spring
|
60Si2Mn
|
|
|
Wave spun film
|
5806 rubber clip 480D nylon 66 mesh fabric
|
1. Main technical parameters of pneumatic control valve mechanism
|
Valve seat diameter mm
|
confluence
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
|
shunt
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
|
|
Rated flow rate
Coefficient kv |
confluence
|
8.5
|
13
|
21
|
34
|
52
|
85
|
125
|
210
|
340
|
535
|
800
|
1260
|
|
shunt
|
25
|
32
|
40
|
50
|
65
|
85
|
125
|
210
|
340
|
535
|
800
|
1260
|
|
|
Nominal pressure MPa
|
1.6 4.0 6.4
|
||||||||||||
|
Travel distance mm
|
16
|
25
|
40
|
60
|
100
|
||||||||
|
Traffic characteristics
|
straight line
|
||||||||||||
|
Medium temperature ℃
|
-20-200, -40 to+250 (normal temperature type), -40 to 315 (medium temperature type)
|
||||||||||||
|
Flange size
|
Cast iron flange size according to JB79-59, cast steel flange size according to JB79-59
|
||||||||||||
|
flange type
|
The flange sealing surface type is in accordance with JB77-59, with cast steel flanges being smooth and cast steel flanges being concave
|
||||||||||||
|
body material
|
HT200,ZG230-450、ZG1Cr18Ni9
|
||||||||||||
|
Valve core material
|
1Cr18Ni9
|
||||||||||||
|
Upper valve cover type
|
Ordinary type (constant temperature type), hot plate type (medium temperature type)
|
||||||||||||
|
rangeability
|
30:1
|
||||||||||||
|
Air source connector
|
M16×1.5
|
||||||||||||
2. Main technical parameters of the executing agency
|
Model number
|
ZHA(B)-3
|
ZHA(B)-4
|
ZHA(B)-5
|
ZHA(B)-6
|
|
Effective area cm2
|
400
|
630
|
1000
|
1600
|
|
Travel distance mm
|
16.25
|
40
|
60
|
1000
|
|
Spring range KPa
|
20~100; 40-200, 20-60, 60-100, 80-240
|
|||
3. Performance indicators
|
project
|
Without locator
|
Equipped with locator
|
||
|
Basic error%
|
±6
|
±1.5
|
||
|
Return difference%
|
5
|
1.5
|
||
|
Dead zone%
|
4
|
0.6
|
||
|
Constant point deviation%
|
air to close
|
Starting point
|
±2.5
|
±1.5
|
|
End
|
±6.0
|
|||
|
air to open
|
Starting point
|
±6.0
|
||
|
End
|
±2.5
|
|||
|
Rated travel deviation%
|
±2.5
|
|||
|
Allowable leakage rate L/h
|
10-3Rated capacity of valve
|
|||
pour4. Allow pressure difference
Accessories available: Positioner handwheel mechanism, air filter, pressure reducer, etc.
Generally, a locator should be included
Note: Diverter valves with a nominal diameter less than 80 shall be replaced by merging valves of the same diameter