Welcome Customer !

Membership

Help

Shenzhen Zhongxun Optical Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Shenzhen Zhongxun Optical Instrument Co., Ltd

  • E-mail

    leonlee@zhongxun17.com

  • Phone

    18165782065

  • Address

    Room 901-2, Mingyuan Business Building, No. 70 Minsheng Avenue, Gongming Street, Guangming New District, Shenzhen

Contact Now

ZXSMU-3030HA Fully Automatic 2.5-Dimensional Optical Image Measuring Instrument

NegotiableUpdate on 12/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Fully automatic measurement software (CNC multifunctional image measurement software) with complete CNC functions, including autofocus, automatic magnification switching, and automatic light source control
Product Details
Fully automated measurement software(CNC multifunctional image measurement software
  • Complete CNC functions, including autofocus, automatic magnification switching, and automatic light source control.
  • Complete geometric measurement (multi-point measurement of points, lines, circles, arcs, rectangles, grooves, improving measurement accuracy, etc.).
  • The automatic edge scanning function of the image is fast, accurate, and has good repeatability. Coupled with a series of powerful image measurement tools, it simplifies the measurement process, making the measurement work easier and more efficient.
  • Supporting powerful measurement functions and convenient and efficient pixel construction, users can easily construct points, lines, circles, arcs, rectangles, grooves, distances, intersections, angles, midpoints, centerlines, verticals, parallels, widths, autofocus, automatic contour 2D scanning, etc. by simply selecting graphics.
  • The measurement pixels can be used for functions such as translation, copying, rotation, array, and mirroring, which can shorten the time required for program production during a large number of measurements.
  • The image data of the measurement process can be stored as SIF files, allowing different batches of objects to be measured at the same position and method each time, avoiding differences in measurement results between different users at different times.
  • For complex workpieces, Dxf and EXCELLON (optional) files can be directly loaded and quickly converted into automatic measurement programs, saving time for manual teaching. Multiple Dxf files can be loaded into the system simultaneously, and the height of the Z-axis displacement for each Dxf file can be set.
  • SI CAD can be used for off machine program editing.
  • For the measurement of duplicate workpieces, it has the function of automatic programming. The measurement process is automatically programmed, which can quickly and accurately measure and greatly shorten the on-site measurement time. Batch measurement of the same workpiece is more convenient and fast.
  • After automatic programming, the report file can be automatically output according to the format set by oneself, and the measurement data of the same workpiece can be automatically classified and saved according to the measurement time.
  • After automatic programming, it is possible to re measure the failed or out of tolerance pixels separately.
  • After automatic programming, the number of measurements can be automatically accumulated.
  • Diversified coordinate system setting methods, including coordinate translation, coordinate rotation, the ability to redefine new coordinate systems, modify coordinate origins, and correct coordinates, make measurement more convenient.
  • Equipped with automatic curve scanning and measurement function, it can quickly calculate the area and circumference of the curve.
  • Multiple SI files can be loaded into the system simultaneously.
  • The calculator function can find maximum, minimum, average, total, numerical range, failed pixels, and NG pixels.
  • It can set geometric tolerances, automatically output tolerances, and have automatic discrimination functions. It can alert users of non-conforming dimensions in the form of colors, markings, etc., making data judgment faster for users.
  • Equipped with 3D view and work platform port switching function.
  • The images in the image area can be output as JPEG format files.
  • The pixel labeling function allows users to quickly and conveniently find measurement pixels when measuring a large number of pixels.
  • Batch pixel processing, selecting the required pixels, quickly executing program instructions, resetting processes, fitting pixels, exporting data, and other functions.
  • The physical shooting function can capture the entire image of the workpiece, enriching the humanized annotation function. It can annotate all two-dimensional plane geometric dimensions and positional tolerances in both actual and virtual images, achieving the highest communication efficiency.
  • Diversified display modes: language switching (Simplified and Traditional Chinese, English, Korean, Italian, Japanese, German, French, etc.), switching between metric and imperial units (mm/inch), angle conversion (degrees/minutes/seconds), customizable decimal points for displaying numbers, switching between coordinate systems, etc.
  • The software seamlessly connects with EXCEL, and the measurement data has graphic and textual printing, data detail report and preview functions. The data report can be printed and exported to Excel for statistical analysis, and can also be exported according to customer format report requirements.
  • The reverse engineering function can be used in conjunction with CAD to achieve mutual conversion between software and AutoCAD engineering drawings, and directly distinguish errors between workpieces and engineering drawings.
  • The drawing area can be used for fixed-point ZoomIn, ZoomOut, Pan, and ZoomAll functions. With full view and zoom in functions, no matter how large the pixel is, it can be viewed without a doubt.
  • Personalized editing in the drawing area: point, line, circle, arc, delete, cut, extend, reverse arc angle, tangent point of circle, two lines and radius to calculate the center of the circle, delete, cut, extend UNDO/REDO, And it can directly do dimension annotation and simple CAD drawing functions and modifications in the full view area.
  • Humanized management of archives, measurement data can be stored in SI, SIF, SXF formats or saved as DXF documents. Measurement results can be imported into professional CAD software using DXF and directly used for development and design.
  • The software contains a built-in data sorting function that can quickly organize measured data, making report organization easier. It can automatically read specified measurement data during the measurement process and calculate statistical coefficients such as maximum, minimum, and average values.
  • You can customize the output report format of graphic elements within the software, such as center coordinates, distance, radius, etc.
  • The LED intelligent ambient light surface cold light source and LED intelligent contour cold light source system completely bid farewell to the traditional rotary light source system. Through full software control of light brightness, the measurement is more perfect, and the partition function can freely change the lighting angle
Instrument working environment
1Temperature and humidity:
Temperature: 20-25 ℃, optimal: 22 ℃; Relative humidity: 50% -60%, optimal: 55%; Maximum temperature change rate in the computer room: 10 ℃/hour; The climate in the northern region is dry, so it is recommended to use a humidifier; The climate in the southern region is humid, it is recommended to use a dehumidifier
2Studio heat calculation:
·To maintain the operation of the equipment system in the workspace at the optimal temperature and humidity, it is necessary to calculate the total indoor heat dissipation, including the total heat dissipation of indoor equipment and instruments (ordinary lighting fixtures can be ignored)
·Human body heat dissipation: 600BTY/hour/person
·Studio heat dissipation: 5/square meter
·Instrument placement space (L * W * H): 2200mm ╳ 2200mm ╳ 2000mm
3Dust content in the air:
The computer room should be kept clean, with no more than 45000 impurities greater than 0.5MLXPOV per cubic foot in the air. If there is too much dust in the air, it can easily cause resource read/write errors and damage to the disks or read-write heads in the disk drive.
4Vibration level in the computer room:
The vibration level in the computer room shall not exceed 0.5T. Machines that generate vibration in the computer room should be avoided from being placed together, as vibration may cause loosening of the mechanical parts, joints, and contact parts of the main panel, resulting in abnormal operation of the machines.
4、 Power supply:
AC220V/50HZ AC110V/60HZ


Similar Product Recommend