Zhejiang High and Low Temperature Thermal Shock Test Chamber

NegotiableUpdate on 07/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: The Zhejiang high and low temperature cold and hot shock test chamber meets the requirements of GB/T2423.5-1995 (Environmental testing for electrical and electronic products - Temperature shock test method). This equipment mainly simulates temperature sudden changes, instantaneous temperature changes from high temperature to low temperature, and then from low temperature to high temperature, and provides a basis for evaluating the performance changes of test samples through repeated temperature changes.

Product Details

ZhejiangHigh and low temperature thermal shock test chambersummary:

The three box thermal shock test chamber is used to test the endurance of components under rapid temperature changes. It is suitable for quality control laboratories and can also meet the screening of commercial and military products in the production process. Thermal storage does not require the use of liquid gas (LN2 or LCO2) to assist in cooling. The static testing method for the test substance is widely used in current electronic component testing, research, and semiconductor production lines, which can save a lot of consumable testing costs and operate quickly.

Zhejiang High and Low Temperature Thermal Shock Test ChamberProduct Features

  • Three box thermal shock test chamber/thermal shock test machine/high and low temperature shock test chamber/temperature shock test chamber

  • For cold and hot shock testing, some standards (MIL-STD, IEC, DIN, etc.) require a brief adjustment step to room temperature during temperature cycling, and this test chamber is designed specifically to meet these standards.

  • The sample tank is stationary and can be wired with an external load through the test hole.

  • The heat storage method can avoid occupational injuries. (Note: The gas produced by liquid gas is inhaled into the lungs, causing a decrease in oxygen levels and leading to work fatigue and reduced concentration.).

  • The impact box adopts a touch sensitive color LCD display human-machine interface controller, which is easy to operate and learn.

  • High temperature control accuracy, all adopt PID automatic calculation control.

  • You can choose the starting position and start cycling at high or low temperatures.

  • It has a reservation start function.

  • Can set the number of cycles and automatic defrosting.

  • The test chamber is divided into three parts: high temperature zone, low temperature zone, and testing zone. Each box body adopts a * insulation structure. During testing, two slot (two box method) or three slot (three box method) impact testing can be selected.

  • The number of cycles and defrosting times can be set for automatic (manual) defrosting. Description and troubleshooting methods for status display and curve, abnormal and fault point display during operation.

Auxiliary functions

Different temperature range impact: correspondingly cut off by the multi-stage evaporator structure, control the evaporation area to match the refrigeration expansion valve, use the refrigeration system output to reasonably reduce the output of the heater neutralization, and achieve constant energy saving; There is also an independent ventilation valve that operates to introduce ambient air into the air intake during exhaust (room temperature recovery). When exposed to ambient temperature, the exhaust port is used to draw in outside air, and hot air is discharged from the mechanical room and test area. The scheduled function sets the start time of the test in advance, and the test chamber automatically starts and prepares. Start the experiment and shorten the exposure time. After the downwind temperature of the functional test area reaches the exposure temperature, switch to the next exposed pre-treatment/post-treatment function. Before or after the cyclic test, the sample is exposed to a high temperature environment (heat treatment) for a certain period of time to maintain dry operation. After the functional test is completed, the low-temperature chamber can operate under dry conditions for a certain period of time.

Our company's main products include:High and low temperature (alternating) damp heat test chamber, high and low temperature (alternating) test chamber, high and low temperature impact test chamber, walk-in high and low temperature alternating damp heat test chamber, high temperature aging room, high and low temperature low-pressure (alternating damp heat) test chamber, high temperature aging test chamber, waterproof (rain) test chamber, flushing device, dustproof (sand/dust) test chamber, single arm drop test machine, salt spray test chamber (precision type), ultraviolet aging test chamber, ozone aging test chamber, xenon climate resistance test chamber, hot wire tester, horizontal and vertical combustion machine, horizontal and vertical vibration table, simulated automobile transportation vibration table, ultra-low humidity moisture-proof cabinet.

Note: Customization is possible without special requirements. If you have any needs to know about our products, please contact our online customer service!