E-mail
shwury@163.com
-
Phone
15800608246
-
Address
Lane 868, Xinge Road, Xinqiao Town, Songjiang District, Shanghai
Shanghai Wurui Automation Equipment Co., Ltd
shwury@163.com
15800608246
Lane 868, Xinge Road, Xinqiao Town, Songjiang District, Shanghai
1WRTFflow switchIntroduction
WRTFseriesflow switchMainly used for flow monitoring and switch output in pipelinesIts solid structure and stable performance can be widely applied In the cooling and lubrication systems of compressors, motors, generators, rolling mills, conveyors, and other machines. When the traffic exceeds or falls belowPre value switch When clicked, it can output a signal. At the same time, this preset switch point can be set at any position within the range, and this switchPoint can be on Easy to adjust under installation conditions.
IIWRTFflow switchTechnical Specifications
WRTF181 |
WRTF182 |
WRTF183 |
WRTF184 |
|
|
measurement range(100%value) Traffic volume( m3/h) flow velocity |
0.16-30 - |
0.16-30 - |
24-250 - |
- 0.4-4 |
|
connect Pipe thread(G)(R) flangeDIN ,HG , GB , JB/T ANSI ,JIS |
3/4-2' - - - |
- DN15-DN50/PN4.0 DN65/PN1.6 1/2' -2' (21/2') |
- DN80(65)-DN150/PN1.6 DN80/PN4.0 DN200/PN1.0 3' (21/2') -8' |
- DN150/PN1.6-PN2.5 - 6' |
|
measurement system Baffle and conical tube Baffle and nozzle baffle |
C E - |
C E - |
- - P |
- - P |
|
instruction Fixed division traffic unit |
GA |
GA |
GA |
G - |
|
Fluid flow direction vertical/From bottom to top /From top to bottom level/In any direction |
VU VOH |
VU VOH |
VU VOH |
- - H |
|
Maximum operating pressure standard form pipe thread flange ANSI Special requirements |
4.0 - - As required |
- 4.0 1.6(DN65) 150Lbs(21/2”) As required |
- 1.6 4.0(DN80) 1.0(DN200) 150Lbs(8”) As required |
- 2.5
As required |
|
medium temperature (°C) standard Ventilation shell High temperature type (No indicator)H2 H3 |
≤120 ≤150 ≤200 ≤300 |
≤120 ≤150 ≤200 ≤300 |
≤120 ≤150 ≤200 ≤300 |
≤120 ≤150 ≤200 ≤300 |
|
medium viscositymPa. s standard special type |
≤30 >30 |
≤30 >30 |
≤30 >30 |
≤30 >30 |
Repeatability of switch points |
±3% |
±3% |
±3% |
±3% |
Flow measurement accuracy (Indicator)A) |
± 15% |
± 15% |
± 15% |
± 15% |
|
limit switch Model and quantity K1 K2
KV1 ,KV2 Contact power K1 ,K2 KV1 ,KV2 |
reed switch |
reed switch |
reed switch |
reed switch |
|
K1Two line switch: 1N/Cor1N/Ocontact point( bistable) K1Three wire switch: 1SPDT K2Two line switch: 1N/Cand1N/Ocontact point( bistable) 2N/Cor2N/Ocontact point K2Three wire switch: 2SPDT 1or2A switch contact with an amplifying relay (bistable) maximum12VA, it is recommended to use24VDCpower supply maximum1200VA ,24VDCor220/ACpower supply | ||||
|
Amplifying relayREL20 power supply response time |
220/117/24VAC ,48/24VDC 5-12ms |
|||
IIIWRTFflow switchlimit switch
WRTF181-184flow switchCan have one or two adjustable limits throughout the entire measurement rangePosition switch.
limit switchK1orK2 What is the maximum power of the reed switch contacts12VAFor larger contact power (maximum)1200VA)The requirements, We adoptKV1orKV2(KV2Limited toGtypeindicator).
4WRTFflow switchindicator
WRTF184flow switchThe basic type is composed of GType indicator group Cheng. Corresponding to the measurement range1/10The graduated dial can be easily Observe traffic. At the same time, this type offlow switchIt can be conveniently Adjust the switch alarm point without interrupting the flow in the pipeline.
WRTF181-WRTF183flow switchCan be done byAType orGType finger Composition of indicators. Corresponding to the measurement range 1/h ,1/min ,m3/h The equally divided circular dial and pointer can facilitate the observation of flow rate. At the same time, this type offlow switchYou can also easily adjust the switch Alarm without interrupting the flow in the pipeline.
fiveTheWRTFflow switchmeasurement system
measurement systemC(WRTF181and WRTF182)By conical tube and Composed of freely movable baffles, it is suitable for handling pure liquids Take measurements.
When the fluid passes through in a specified directionflow switchTime measurement gear The plate generates displacement based on the flow rate, and the displacement is related to the highly stable spring Elasticity is in equilibrium, and each determined flow corresponds to a flat state Balance position. Sensors installed in isolated environments of measurement systems Magnetic coupling indicates flow rate and outputs control signals.
Magnetic lever capable of freely rotating on PTFE sealing ring Capable of preventing particles from entering the medium and equipped with calibrated control magnets Inside the cabin with springs.
measurement system ESuitable for measuring particles containing small particles or those that may The medium blocking the pipeline (only applicable to)WRTF181-182).
measurement systemPApplication and measurement systemESimilar, just measuring systemPThere is no nozzle in it (only applicable to)WRTF183-184).